Skip to main content Skip to navigation
RY610 Rat Anti-Mouse Ly-49A
561302
¥49,610
EA (1 Each)
50 µg
Add Product To Quote見積に追加
製品詳細
Down Arrow


BD OptiBuild™
Klra1; lymphocyte antigen 49a; Ly-49a; Ly49a; YE1/48; A1
Mouse (Tested in Development)
Rat F344, also known as Fischer, CDF IgG2b
ECA17.9.8 T Cell Line
Flow cytometry (Qualified)
0.2 mg/ml
16627
AB_3691597
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


Preparation and Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated to the dye under optimum conditions that minimize unconjugated dye and antibody.

推奨アッセイ手順

BD® CompBeads can be used as surrogates to assess fluorescence spillover (compensation). When fluorochrome conjugated antibodies are bound to BD® CompBeads, they have spectral properties very similar to cells. However, for some fluorochromes there can be small differences in spectral emissions compared to cells, resulting in spillover values that differ when compared to biological controls. It is strongly recommended that when using a reagent for the first time, users compare the spillover on cells and BD® CompBeads to ensure that BD® CompBeads are appropriate for your specific cellular application.

Product Notices

  1. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  2. Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
  3. For U.S. patents that may apply, see bd.com/patents.
  4. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  5. Since applications vary, each investigator should titrate the reagent to obtain optimal results.
  6. The production process underwent stringent testing and validation to assure that it generates a high-quality conjugate with consistent performance and specific binding activity. However, verification testing has not been performed on all conjugate lots.
  7. Please observe the following precautions: We recommend that special precautions be taken (such as wrapping vials, tubes, or racks in aluminum foil) to protect exposure of conjugated reagents, including cells stained with those reagents, to any room illumination. Absorption of visible light can significantly affect the emission spectra and quantum yield of tandem fluorochrome conjugates.
  8. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  9. An isotype control should be used at the same concentration as the antibody of interest.
  10. CF™ is a trademark of Biotium, Inc.

データシート

759515 Rev. 2
抗体の詳細
Down Arrow
YE1/48.10.6

The YE1/48.10.6 monoclonal antibody specifically recognizes Lymphocyte antigen 49a (Ly-49A). Ly-49A is a single-pass type-II transmembrane that is encoded by Klra1 (Killer cell lectin-like receptor, subfamily A member 1) which belongs to the C-type lectin superfamily. Ly-49A is comprised of an extracellular carbohydrate-recognition domain (CRD) that can bind strongly to H-2D MHC class I alloantigens expressed on target cells including H-2D[d], H-2D[k], and H-2D[p]. The extracellular domain is followed by a transmembrane region and a cytoplasmic domain with an immunoreceptor tyrosine-based inhibitory motif (ITIM). Ly-49A is expressed as a  disulfide-linked homodimer on a subset of NK and NK-T cells. MHC Class I ligand-bound Ly-49A can negatively regulate NK-cell cytolytic activity via tyrosine phosphorylation of its ITIM.

759515 Rev. 2
フォーマットの詳細
Down Arrow
RY610
The BD Horizon RealYellow™ 610 (RY610) Dye is part of the BD® family of yellow-green dyes. It is a tandem fluorochrome with an excitation maximum (Ex Max) at 557-nm and an emission maximum (Em Max) at 610-nm as measured using an antibody-dye conjugate. Driven by BD® innovation, RY610 can be used on both spectral and conventional cytometers and is designed to be excited by the Yellow-Green laser (561-nm) with minimal excitation by the 488-nm blue laser. For conventional instruments equipped with a Yellow-Green laser (561-nm), RY610 can be used as an alternative to PE-CF594 and we recommend using an optical filter centered near 610-nm (eg, a 610/20-nm bandpass filter). For spectral instruments equipped with a Yellow-Green laser (561-nm), it can be used in conjunction with PE-CF594.
altImg
RY610
Yellow-Green 561 nm
557 nm
610 nm
759515 Rev.2
引用&参考文献
Down Arrow

Development References (6)

  1. Chan PY, Takei F. Expression of a T cell receptor-like molecule on normal and malignant murine T cells detected by rat monoclonal antibodies to nonclonotypic determinants.. J Immunol. 1986; 136(4):1346-53. (Immunogen: Blocking, Flow cytometry, Immunoprecipitation, Western blot). View Reference
  2. Mason LH, Gosselin P, Anderson SK, Fogler WE, Ortaldo JR, McVicar DW. Differential tyrosine phosphorylation of inhibitory versus activating Ly-49 receptor proteins and their recruitment of SHP-1 phosphatase. J Immunol. 1997; 159(9):4187-4196. (Biology: Blocking). View Reference
  3. Nagasawa R, Gross J, Kanagawa O, et al. Identification of a novel T cell surface disulfide-bonded dimer distinct from the alpha/beta antigen receptor. J Immunol. 1987; 138(3):815-824. (Biology). View Reference
  4. Nakamura MC, Seaman WE. Ligand interactions by activating and inhibitory Ly-49 receptors.. Immunol Rev. 2001; 181:138-48. (Biology). View Reference
  5. Takei F. Two surface antigens expressed on proliferating mouse T lymphocytes defined by rat monoclonal antibodies.. J Immunol. 1983; 130(6):2794-7. (Immunogen: Flow cytometry, Radioimmunoassay, Western blot). View Reference
  6. Zimmer J, Ioannidis V, Held W. H-2D ligand expression by Ly49A+ natural killer (NK) cells precludes ligand uptake from environmental cells: implications for NK cell function.. J Exp Med. 2001; 194(10):1531-9. (Clone-specific: Flow cytometry). View Reference
すべて表示する (6) 表示項目を減らす
759515 Rev. 2

Please refer to Support Documents for Quality Certificates

 

Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described

 

Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.