Skip to main content Skip to navigation
RY610 Mouse Anti-Human TCR Vβ11
569319
¥123,200
EA (1 Each)
50 µg
Add Product To Quote見積に追加
製品詳細
Down Arrow


BD OptiBuild™
TCR V beta 11; TCR Vbeta11; TCRBV11S1; TRBV251
Human (Tested in Development)
Mouse BALB/c IgG2a, κ
T Cell Clone
Flow cytometry (Qualified)
0.2 mg/ml
28582
AB_3690685
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


Preparation and Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated to the dye under optimum conditions that minimize unconjugated dye and antibody.

推奨アッセイ手順

BD® CompBeads can be used as surrogates to assess fluorescence spillover (compensation). When fluorochrome conjugated antibodies are bound to BD® CompBeads, they have spectral properties very similar to cells. However, for some fluorochromes there can be small differences in spectral emissions compared to cells, resulting in spillover values that differ when compared to biological controls. It is strongly recommended that when using a reagent for the first time, users compare the spillover on cells and BD® CompBeads to ensure that BD® CompBeads are appropriate for your specific cellular application.

Product Notices

  1. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  2. Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
  3. For U.S. patents that may apply, see bd.com/patents.
  4. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  5. Since applications vary, each investigator should titrate the reagent to obtain optimal results.
  6. The production process underwent stringent testing and validation to assure that it generates a high-quality conjugate with consistent performance and specific binding activity. However, verification testing has not been performed on all conjugate lots.
  7. Please observe the following precautions: We recommend that special precautions be taken (such as wrapping vials, tubes, or racks in aluminum foil) to protect exposure of conjugated reagents, including cells stained with those reagents, to any room illumination. Absorption of visible light can significantly affect the emission spectra and quantum yield of tandem fluorochrome conjugates.
  8. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  9. An isotype control should be used at the same concentration as the antibody of interest.
  10. CF™ is a trademark of Biotium, Inc.
  11. Human donor specific background has been observed in relation to the presence of anti-polyethylene glycol (PEG) antibodies, developed as a result of certain vaccines containing PEG, including some COVID-19 vaccines. We recommend use of BD Horizon Brilliant™ Stain Buffer in your experiments to help mitigate potential background. For more information visit https://www.bdbiosciences.com/en-us/support/product-notices.

データシート

758557 Rev. 1
抗体の詳細
Down Arrow
C21

The C21 monoclonal antibody specifically recognizes the variable beta 11 region of the β subunit of the human αβ T cell receptor for antigen (TCR Vβ11). TCR Vβ11 is encoded by TRBV25-1 (T cell receptor beta variable 25-1) which is also known as TCRBV11S1. TCR Vβ11 can pair with different TCR Vα region containing TCR α chains. The paired expression of semivariant TCR Vβ11 with invariant TCR Vα24 and Jα18  identifies some CD3+TCR αβ+ positive thymocytes and from ~ 0.01-0.92%  of peripheral blood CD3+ TCR αβ+ T cells known as invariant NKT (iNKT) cells or Type I NKT cells. iNKT cells can be divided into three subpopulations which are either CD4+, CD8+, or CD4-CD8- double negative. Due to their innate-like responsiveness, tissue resident iNKT cells are capable of rapid effector responses to microbial or self-lipid antigens presented by the cell surface MHC class Ib molecule, CD1d. iNKT cells recognize and respond to α-galactosylceramide (α-GalCer) and various self-lipids such as sphingolipids and diacylglycerols and microbial lipids presented by CD1d. iNKT cells can produce high levels of cytokines, including IL-4 and IFN-γ, and act as cytotoxic T cells against CD1d+ target cells following stimulation. The C21 antibody is useful for multiparameter cell sorting and phenotypic analyses designed to study the nature of TCR Vβ11-positive T cells and T cell clones. When combined with other TCR V region-specific antibodies, C15 is helpful for characterizing TCR Vβ repertoires expressed by T cell populations collected from blood, tissues or other sources in health and disease models including inflammation, infectious diseases, autoimmunity, and tumors.

758557 Rev. 1
フォーマットの詳細
Down Arrow
RY610
The BD Horizon RealYellow™ 610 (RY610) Dye is part of the BD® family of yellow-green dyes. It is a tandem fluorochrome with an excitation maximum (Ex Max) at 557-nm and an emission maximum (Em Max) at 610-nm as measured using an antibody-dye conjugate. Driven by BD® innovation, RY610 can be used on both spectral and conventional cytometers and is designed to be excited by the Yellow-Green laser (561-nm) with minimal excitation by the 488-nm blue laser. For conventional instruments equipped with a Yellow-Green laser (561-nm), RY610 can be used as an alternative to PE-CF594 and we recommend using an optical filter centered near 610-nm (eg, a 610/20-nm bandpass filter). For spectral instruments equipped with a Yellow-Green laser (561-nm), it can be used in conjunction with PE-CF594.
altImg
RY610
Yellow-Green 561 nm
557 nm
610 nm
758557 Rev.1
引用&参考文献
Down Arrow
No Citations Found

No Citations Are Available for this Product

758557 Rev. 1

Please refer to Support Documents for Quality Certificates

 

Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described

 

Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.