Skip to main content Skip to navigation
APC Mouse anti-Human Ig, κ Light Chain
APC Mouse anti-Human Ig, κ Light Chain
Flow cytometric analysis of Ig κ Light Chain expression on human peripheral blood lymphocytes. Human peripheral blood mononuclear cells (PBMC) were incubated in complete tissue culture medium overnight in order to minimize subsequent nonspecific immunofluorescent staining. The cells were harvested and stained with Alexa Fluor® 488 Mouse anti-Human CD19 (Cat. No. 557697) and either APC Mouse anti-Human Ig κ Light Chain antibody (Cat. No. 561323; Right Panel) or APC Mouse IgG1, κ Isotype Control (Cat. No. 554681; Left Panel) and. The two-color flow cytometric dot plots showing the correlated expression of Ig κ Light Chain (or Ig isotype control staining) versus CD19 were derived from events with the forward and side light-scatter characteristics of viable lymphocytes. Flow cytometry was performed using a BD™ LSR II Flow Cytometer System.
Flow cytometric analysis of Ig κ Light Chain expression on human peripheral blood lymphocytes. Human peripheral blood mononuclear cells (PBMC) were incubated in complete tissue culture medium overnight in order to minimize subsequent nonspecific immunofluorescent staining. The cells were harvested and stained with Alexa Fluor® 488 Mouse anti-Human CD19 (Cat. No. 557697) and either APC Mouse anti-Human Ig κ Light Chain antibody (Cat. No. 561323; Right Panel) or APC Mouse IgG1, κ Isotype Control (Cat. No. 554681; Left Panel) and. The two-color flow cytometric dot plots showing the correlated expression of Ig κ Light Chain (or Ig isotype control staining) versus CD19 were derived from events with the forward and side light-scatter characteristics of viable lymphocytes. Flow cytometry was performed using a BD™ LSR II Flow Cytometer System.
製品詳細
Down Arrow Up Arrow


BD Pharmingen™
Ig, kappa Light Chain; IGKC; HCAK1; Km; Ig kappa chain C region
Human (QC Testing)
Mouse IgG1, κ
Flow cytometry (Routinely Tested)
5 µl
3514
AB_10612012
Aqueous buffered solution containing BSA and ≤0.09% sodium azide.
RUO


Preparation and Storage

The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated to APC under optimum conditions, and unconjugated antibody and free APC were removed. Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze.

Product Notices

  1. This reagent has been pre-diluted for use at the recommended Volume per Test. We typically use 1 × 10^6 cells in a 100-µl experimental sample (a test).
  2. An isotype control should be used at the same concentration as the antibody of interest.
  3. Source of all serum proteins is from USDA inspected abattoirs located in the United States.
  4. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  5. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  6. This APC-conjugated reagent can be used in any flow cytometer equipped with a dye, HeNe, or red diode laser.
  7. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
561323 Rev. 1
抗体の詳細
Down Arrow Up Arrow
G20-193

The G20-193 monoclonal antibody specifically binds to human immunoglobulin light chain, kappa (κ). It does not react with human immunoglobulin λ light chains or human immunoglobulin heavy chains.

561323 Rev. 1
フォーマットの詳細
Down Arrow Up Arrow
APC
Allophycocyanin (APC), is part of the BD family of phycobiliprotein dyes. This fluorochrome is a multimeric fluorescent phycobiliprotein with excitation maximum (Ex Max) of 651 nm and an emission maximum (Em Max) at 660 nm. APC is designed to be excited by the Red (627-640 nm) laser and detected using an optical filter centered near 660 nm (e.g., a 660/20 nm bandpass filter). Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
altImg
APC
Red 627-640 nm
651 nm
660 nm
561323 Rev.1

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.