Skip to main content Skip to navigation
Mouse Th1/Th2/Th17 CBA Kit

BD™ Cytometric Bead Array (CBA) Mouse Th1/Th2/Th17 CBA Kit

(RUO)
製品詳細
Down Arrow Up Arrow


BD™ Cytometric Bead Array (CBA)
Mouse (QC Testing)
Flow cytometry (Routinely Tested)
RUO
AB_2869354


560485 Rev. 1
構成品
Down Arrow Up Arrow
説明 数量/容量 Part Number EntrezGene ID
Mouse IL-2 Capture Beads 0.8 mL (1 ea) 51-9005801 N/A
Mouse IL-4 Capture Beads 0.8 mL (1 ea) 51-9005803 N/A
Mouse IL-6 Capture Beads 100 Tests (1 ea) 51-9006293 N/A
Mouse IFN-γ Capture Beads 0.8 mL (1 ea) 51-9005807 N/A
Mouse TNF Capture Beads 0.8 mL (1 ea) 51-9005809 N/A
Mouse IL-17A Capture Beads 100 Tests (1 ea) 51-9006295 N/A
Mouse IL-10 Capture Beads 100 Tests (1 ea) 51-9006297 N/A
B Mouse Th1/Th2/Th17 PE Detection Reagent N/A 51-9006299 N/A
C) Mouse Th1/Th2/Th17 Cytokine Standards N/A 51-9006250 N/A
D Cytometer Setup Beads 1 Each (1 ea) 51-9005731 N/A
E1 PE Positive Control Detector 1 Each (1 ea) 51-9005732 N/A
E2 FITC Positive Control Detector 1 Each (1 ea) 51-9005734 N/A
F Wash Buffer 1 Each (1 ea) 51-2431KC N/A
G Assay Diluent 1 Each (1 ea) 51-2432KC N/A
560485 Rev. 1
引用&参考文献
Down Arrow Up Arrow

開発者向け参考資料 (11)

  1. Bishop JE, Davis KA. A flow cytometric immunoassay for β2-microglobulin in whole blood. J Immunol Methods. 1997; 210:79–87. (Biology).
  2. Camilla C, Defoort JP, Delaage M, et al. A new flow cytometry-based multi-assay system 1, Application to cytokine immunoassays. Cytometry Suppl. 1998; 8:132. (Biology).
  3. Carson R, Vignali D. Simultaneous quantitation of 15 cytokines using a multiplexed flow cytometric assay. J Immunol Methods. 1999; 227:41–52. (Biology).
  4. Chen, R, L Lowe, et al. Simultaneous quantification of six human cytokines in a single sample using microparticle-based flow cytometric technology. Clin Chem. 1999; 9:1693-1694. (Biology).
  5. Collins DP, Luebering BJ, Shaut DM. T-lymphocyte functionality assessed by analysis of cytokine receptor expression, intracellular cytokine expression, and femtomolar detection of cytokine secretion by quantitative flow cytometry. Cytometry. 1998; 33:249-255. (Biology).
  6. Fulton RJ, McDade RL, Smith PL, Kienker LJ, Kettman JR Jr. Advanced multiplexed analysis with the FlowMetrix system. Clin Chem. 1997; 43:1749-1756. (Biology).
  7. Fulwyler M, McHugh TM. Flow microsphere immunoassay for the quantitative and simultaneous detection of multiple soluble analytes. Methods Cell Biol. 1994; 33:613-629. (Biology).
  8. Kricka LJ. Diamandis EP, Christopoulos TK, ed. Immunoassay. Academic Press; 1996:389-404.
  9. Lund-Johansen F, Davis K, Bishop J, de Waal Malefyt R. Flow cytometric analysis of immunoprecipitates: high-throughput analysis of protein phosphorylation and protein-protein interactions. Cytometry. 2000; 39(4):250-259. (Biology). 参考文献を見る
  10. Oliver KG, Kettman JR, Fulton RJ. Multiplexed analysis of human cytokines by use of the FlowMetrix system. Clin Chem. 1998; 44:2057-2060. (Biology).
  11. Stall, A, Q Sun, et al. A single tube flow cytometric multibead assay for isotyping mouse monoclonal antibodies, Abstract LB77. Experimental Biology Meeting. 1998. (Biology).
すべて表示する (11) 表示項目を減らす
560485 Rev. 1

Please refer to Support Documents for Quality Certificates

Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described

Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.