Your selected country is
Japan
- Change country/language
-
抗体試薬
- フローサイトメトリー用試薬
-
ウェスタンブロッティング抗体試薬
- イムノアッセイ試薬
-
シングルセル試薬
- BD® AbSeq Assay | シングルセル試薬
- BD Rhapsody™ Accessory Kits | シングルセル試薬
- BD® Single-Cell Multiplexing Kit | シングルセル試薬
- BD Rhapsody™ Targeted mRNA Kits | シングルセル試薬
- BD Rhapsody™ Whole Transcriptome Analysis (WTA) Amplification Kit | シングルセル試薬
- BD® OMICS-Guard Sample Preservation Buffer
- BD Rhapsody™ ATAC-Seq Assays
- BD Rhapsody™ TCR/BCR Next Multiomic Assays
-
細胞機能評価のための試薬
-
顕微鏡・イメージング用試薬
-
細胞調製・分離試薬
-
- BD® AbSeq Assay | シングルセル試薬
- BD Rhapsody™ Accessory Kits | シングルセル試薬
- BD® Single-Cell Multiplexing Kit | シングルセル試薬
- BD Rhapsody™ Targeted mRNA Kits | シングルセル試薬
- BD Rhapsody™ Whole Transcriptome Analysis (WTA) Amplification Kit | シングルセル試薬
- BD® OMICS-Guard Sample Preservation Buffer
- BD Rhapsody™ ATAC-Seq Assays
- BD Rhapsody™ TCR/BCR Next Multiomic Assays
- Japan (Japanese)
- Change country/language
Old Browser
Looks like you're visiting us from {countryName}.
Would you like to stay on the current country site or be switched to your country?
BD™ Cytometric Bead Array (CBA) Human IL-3 Flex Set
(RUO)Figure 1. Example BD CBA Human IL-3 Flex Set standard curve. Data acquired on a BD FACSArray bioanalyzer and analyzed using FCAP Array Software.
Reproducibility: The inter-assay and intra-assay reproducibility were determined for the BD CBA Human IL-3 Flex Set by evaluating ten replicates of three different sample levels (intra-assay) and two replicates of three different sample levels from four separate experiments (inter-assay).
Recovery: Cell culture supernatant, serum, or EDTA-treated plasma were spiked with three different levels of protein. The spiked samples were assayed and the results were compared with expected values. Serum and plasma samples were diluted 1:4 before the protein was spiked into each. Serum is a pool of 800 - 1000 donors and the plasma was pooled from at least 20 donors.
Linearity: Cell culture supernatant, 1:4 diluted serum, or 1:4 diluted EDTA-treated plasma were spiked with protein and serially diluted. The diluted samples were assayed and the results were compared with the original spiked sample.
BD™ Cytometric Bead Array (CBA) Human IL-3 Flex Set
BD™ Cytometric Bead Array (CBA) Human IL-3 Flex Set
BD™ Cytometric Bead Array (CBA) Human IL-3 Flex Set
BD™ Cytometric Bead Array (CBA) Human IL-3 Flex Set
Human IL-3 Flex Set
Regulatory Statusの凡例
Becton, Dickinson and Companyの書面による明示的な許諾を得た使用以外での製品の使用は固く禁じられています。
説明
The BD™ CBA Human IL-3 Flex Set is a bead-based immunoassay capable of measuring human interleukin-3 (IL-3) in serum, plasma, and cell culture supernatant samples. Human reactivity was determined by testing samples with the BD CBA Human IL-3 Flex Set. The biology and function of IL-3 has been extensively reviewed in the literature. For more information on bead-based immunoassays, refer to the product insert for the BD CBA Human Soluble Protein Master Buffer Kit (Cat. No. 558264 or 558265).
調製と保管
推奨アッセイ手順
The BD CBA Human IL-3 Flex Set must be used in conjunction with a BD CBA Human Soluble Protein Master Buffer Kit (Cat. No. 558264, 100 tests, or 558265, 500 tests), a flow cytometer, and FCAP Array™ Software. Detailed instructions on the use of this product can be found in the manual for the BD CBA Human Soluble Protein Master Buffer Kit. When following the directions in the Master Buffer Kit, the top standard point for the BD CBA Human IL-3 Flex Set will be 2,500 pg/mL. An example standard curve is shown in Figure 1.
When multiplexing the BD CBA Human IL-3 Flex Set assay with the BD CBA Human IL-7 Flex Set assay (Cat. No. 558334), BD CBA Human IL-8 Flex Set assay (Cat. No. 558277), BD CBA Human IL-9 Flex Set assay (Cat. No. 558333) and BD CBA Human IL-10 Flex Set assay (Cat. No. 558274), significantly higher background will be seen in the human IL-3 assay. This increased background, while reducing the sensitivity, will not effect the quantitation of human IL-3 in any other way. There is no effect on the human IL-7, IL-8, IL-9 or IL-10 assays. The BD CBA Human IL-3 Flex Set cannot be used in the same assay well with the following BD CBA Human Soluble Protein Flex Set reagents:
Flex Set Bead Position Catalog Number
BD CBA Human IL-12/IL-23p40 Flex Set E5 560154
BD CBA Human LT-α Flex Set D5 560083
BD CBA Human OSM Flex Set D5 560084
The BD CBA Human IL-3 Flex Set should not be used in the same assay well with any non-BD CBA Human Soluble Protein Flex Set reagents (such as BD CBA Mouse Soluble Protein or Cell Signaling Flex Sets). For an updated assay compatibility chart for the BD CBA Human Soluble Protein Flex Sets, please refer to the BD CBA Flex Set System homepage at http://www.bdbiosciences.com/cbasetup.
Performance
Limit of Detection: The theoretical limit of detection is 0.3 pg/mL and was determined by evaluating the estimated result of the average MFI of the negative control (0 pg/mL, n=30) + 2 standard deviations.
製品通知
- ProClin is a trademark of Rohm and Haas Company.
- Source of all serum proteins is from USDA inspected abattoirs located in the United States.
- Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
- Warning: CBA lyophilized standard contains 0.02% (w/w) of a CMIT/MIT mixture (3:1), which is a mixture of:5-chloro-2-methyl-4-isothiazolin-3-one [EC No 247-500-7] and 2-methyl-4-isothiazolin-3-one [EC No 220-239-6] (3:1).Hazard statement: May cause an allergic skin reaction.Precautionary statements: Contaminated work clothing should not be allowed out of the workplace. Wear protective gloves/eye/face protection. Wear protective clothing. Avoid breathing mist/vapours/spray. If skin irritation or rash occurs: Get medical advice/attention. IF ON SKIN: Wash with plenty of water. Take off contaminated clothing and wash it before reuse. Dispose of contents/container in accordance with local/regional/national/international regulations.
説明 | 数量/容量 | Part Number | EntrezGene ID |
---|---|---|---|
Human IL-3 Standard | N/A | 51-9004270 | N/A |
Human IL-3 PE Detection Reagent | N/A | 51-9004363 | N/A |
Human IL-3 Capture Bead D5 | 100 Tests (1 ea) | 51-9005335 | N/A |
Please refer to Support Documents for Quality Certificates
Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described
Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims. Comparisons are not made against non-BD technologies, unless otherwise noted.
For Research Use Only. Not for use in diagnostic or therapeutic procedures.