-
Your selected country is
Japan
- Change country/language
-
抗体試薬
- フローサイトメトリー用試薬
-
ウェスタンブロッティング抗体試薬
- イムノアッセイ試薬
-
シングルセル試薬
- BD® AbSeq Assay | シングルセル試薬
- BD Rhapsody™ Accessory Kits | シングルセル試薬
- BD® Single-Cell Multiplexing Kit | シングルセル試薬
- BD Rhapsody™ Targeted mRNA Kits | シングルセル試薬
- BD Rhapsody™ Whole Transcriptome Analysis (WTA) Amplification Kit | シングルセル試薬
- BD® OMICS-Guard Sample Preservation Buffer
- BD Rhapsody™ ATAC-Seq Assays
- BD Rhapsody™ TCR/BCR Next Multiomic Assays
-
細胞機能評価のための試薬
-
顕微鏡・イメージング用試薬
-
細胞調製・分離試薬
-
- BD® AbSeq Assay | シングルセル試薬
- BD Rhapsody™ Accessory Kits | シングルセル試薬
- BD® Single-Cell Multiplexing Kit | シングルセル試薬
- BD Rhapsody™ Targeted mRNA Kits | シングルセル試薬
- BD Rhapsody™ Whole Transcriptome Analysis (WTA) Amplification Kit | シングルセル試薬
- BD® OMICS-Guard Sample Preservation Buffer
- BD Rhapsody™ ATAC-Seq Assays
- BD Rhapsody™ TCR/BCR Next Multiomic Assays
- Japan (Japanese)
- Change country/language
Old Browser
Looks like you're visiting us from {countryName}.
Would you like to stay on the current country site or be switched to your country?
Expression of IFN-γ by stimulated human peripheral blood mononuclear cells (PBMC). Human PBMC were stimulated for 6 hours with PMA (50 ng/ml final concentration; Sigma, Cat. No. P-8139) and calcium ionophone A23187 (250 ng/ml final concentration; Sigma, Cat. No. C-9275) in the presence of GolgiStop™ (2 µM final concentration; Cat. No. 554724). The PBMC were stained with PE-Cy5 (formerly referred to as BD-Cy-Chrome™) - anti-CD3 (Cy-Chrome™ - UCHT1, Cat. No. 555334), fixed, permeabilized, and subsequently stained with 0.25 µg of FITC-mouse anti-human IFN-γ antibody (FITC-4S.B3, Cat. No. 554551; left panel) or FITC-MOPC-21 immunoglobulin (0.25 µg; Cat. No. 554679; right panel) by using the BD Bioscience staining protocol. To demonstrate specificity of staining, the binding of FITC-4S.B3 was blocked by preincubation of fixed/permeabilized cells with excess unlabelled 4S.B3 antibody (5 µg; Cat. No. 554549). The quadrant markers for the bivariate dot plot were set based on autofluorescence controls and verified using the unlabelled 4S.B3 antibody blocking control.
BD Pharmingen™ FITC Mouse IgG1, κ Isotype Control
Regulatory Statusの凡例
Any use of products other than the permitted use without the express written authorization of Becton, Dickinson and Company is strictly prohibited.
Preparation and Storage
推奨アッセイ手順
Immunofluorescent Staining and Flow Cytometric Analysis: The FITC-MOPC-21 immunoglobulin (Cat. No. 554679) is a suitable mouse IgG1 isotype control for assessing the level of background staining on paraformaldehyde-fixed/saponin-permeabilized mouse or human cells for flow cytometric analysis. Use at comparable concentrations to antibody of interest (e.g., ≤ 0.5 µg mAb/1 million cells) (figure right panel).
Product Notices
- Since applications vary, each investigator should titrate the reagent to obtain optimal results.
- Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
- Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
関連製品
The MOPC-21 immunoglobulin is a mouse myeloma protein. The MOPC-21 immunoglobulin was selected as an isotype control following screening for low background on a variety of mouse and human tissues.
This antibody is routinely tested by flow cytometric analysis. Other applications were tested at BD Biosciences Pharmingen during antibody development only or reported in the literature.
Development References (1)
-
Prussin C, Metcalfe DD. Detection of intracytoplasmic cytokine using flow cytometry and directly conjugated anti-cytokine antibodies. J Immunol Methods. 1995; 188(1):117-128. (Biology: Flow cytometry). View Reference
Please refer to Support Documents for Quality Certificates
Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described
Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims. Comparisons are not made against non-BD technologies, unless otherwise noted.
For Research Use Only. Not for use in diagnostic or therapeutic procedures.