抗体試薬
- フローサイトメトリー用試薬
-
ウェスタンブロッティング抗体試薬
- イムノアッセイ試薬
-
シングルセル試薬
- BD® AbSeq Assay
- BD Rhapsody™ Accessory Kits
- BD® OMICS-One Immune Profiler Protein Panel
- BD® Single-Cell Multiplexing Kit
- BD Rhapsody™ TCR/BCR Next Multiomic Assays
- BD Rhapsody™ Targeted mRNA Kits
- BD Rhapsody™ Whole Transcriptome Analysis (WTA) Amplification Kit
- BD® OMICS-Guard Sample Preservation Buffer
- BD Rhapsody™ ATAC-Seq Assays
- BD® OMICS-One Protein Panels
-
細胞機能評価のための試薬
-
顕微鏡・イメージング用試薬
-
細胞調製・分離試薬
-
- BD® AbSeq Assay
- BD Rhapsody™ Accessory Kits
- BD® OMICS-One Immune Profiler Protein Panel
- BD® Single-Cell Multiplexing Kit
- BD Rhapsody™ TCR/BCR Next Multiomic Assays
- BD Rhapsody™ Targeted mRNA Kits
- BD Rhapsody™ Whole Transcriptome Analysis (WTA) Amplification Kit
- BD® OMICS-Guard Sample Preservation Buffer
- BD Rhapsody™ ATAC-Seq Assays
- BD® OMICS-One Protein Panels
- Japan (Japanese)
-
Change country/language
Old Browser
Looks like you're visiting us from {countryName}.
Would you like to stay on the current country site or be switched to your country?
BD™ Cytometric Bead Array (CBA) Human MCP-1 Standard


Regulatory Statusの凡例
Becton, Dickinson and Companyの書面による明示的な許諾を得た使用以外での製品の使用は固く禁じられています。
説明
This product contains lyophilized recombinant human monocyte chemoattractant protein-1 (MCP-1). When reconstituted, this product can be used as a standard control with the BD™ CBA Human MCP-1 Flex Set (Cat. No. 558287). Please refer to the technical data sheet included with the Human MCP-1 Flex Set for further information.
調製と保管タイトルテキスト
Lyosphere(s) from 1 vial of Human MCP-1 Standard, when reconstituted in 4.0 mL Assay Diluent, approximates the CBA activity of Human MCP-1 at a concentration of 2500 pg/mL. Following reconstitution, maintain the Human MCP-1 at 4°C and use within 12 hours. Any unused reconstituted standard must be discarded after this period (do not store or reuse).
推奨アッセイ手順
The Human MCP-1 Standard has been tested to assure to function as a standard when used with the BD™ Cytometric Bead Array (CBA), such as the BD™ CBA Human MCP-1 Flex Set (Cat. No. 558287). Investigators are encouraged to refer to the technical data sheet for the BD™ CBA Human MCP-1 Flex Set (Cat. No. 558287). An abbreviated instruction has been provided below (Preparation of Human MCP-1 Standard Protocol). The Human MCP-1 Standard should be reconstituted using Assay Diluent, which is provided with the BD™ CBA Human Soluble Protein Master Buffer Kit (Cat. No. 558264 or 558265) or it may also be purchased separately (Cat. No. 560104).
Preparation of Human MCP-1 Standard: The Human MCP-1 Standard is lyophilized and should be reconstituted and serially diluted before mixing with CBA capture beads and PE detection reagents.
1. Open one vial of the lyophilized Human MCP-1 Standard. Transfer the lyosphere(s) to a polypropylene tube (BD Falcon™, Cat. No. 352097). Label the tube "Top Standard".
2. Reconstitute the standard with 4.0 mL of Assay Diluent. Allow the reconstituted standard to equilibrate for at least 15 minutes before making dilutions. Mix the reconstituted protein by pipette only. Do not vortex or mix vigorously.
3. Label additional 12 x 75 mm tubes (BD Falcon™, Cat. No. 352008) and arrange them in the following order: Top Standard, 1:2, 1:4, 1:8, 1:16, 1:32, 1:64, 1:128, and 1:256.
4. Add 500 µl of Assay Diluent to each of the dilution tubes.
5. Perform a serial dilution by transferring 500 µl from the Top Standard to the 1:2 dilution tube and mix thoroughly. Do not vortex, mix by pipet only. Continue making serial dilutions by transferring 500 µl from the 1:2 tube to the 1:4 tube and so on to the 1:256 tube and mix thoroughly. Prepare one tube containing only Assay Diluent to serve as the 0 pg/mL negative control.
製品通知
- Source of all serum proteins is from USDA inspected abattoirs located in the United States.
- ProClin is a trademark of Rohm and Haas Company.
- Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
- Warning: CBA lyophilized standard contains 0.02% (w/w) and Detection Reagent (Part A) contains 0.002% (w/w) of a CMIT/MIT mixture (3:1), which is a mixture of: 5-chloro-2-methyl-4-isothiazolin-3-one [EC No 247-500-7] and 2-methyl-4-isothiazolin-3-one [EC No 220-239-6] (3:1).Hazard statement: May cause an allergic skin reaction.Precautionary statements: Contaminated work clothing should not be allowed out of the workplace. Wear protective gloves/eye/face protection. Wear protective clothing. Avoid breathing mist/vapours/spray. If skin irritation or rash occurs: Get medical advice/attention. IF ON SKIN: Wash with plenty of water. Take off contaminated clothing and wash it before reuse. Dispose of contents/container in accordance with local/regional/national/international regulations.
Please refer to Support Documents for Quality Certificates
Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described
Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims. Comparisons are not made against non-BD technologies, unless otherwise noted.
For Research Use Only. Not for use in diagnostic or therapeutic procedures.