BD Pharmingen™ PE Mouse IgG1, κ Isotype Control
クローン MOPC-21 (also known as MOPC21; MOPC 21) (RUO)
Regulatory Statusの凡例
Any use of products other than the permitted use without the express written authorization of Becton, Dickinson and Company is strictly prohibited.
Preparation and Storage
推奨アッセイ手順
Immunofluorescent Staining and Flow Cytometric Analysis: The PE-MOPC-21 immunoglobulins are suitable mouse IgG1κ isotype controls for assessing the level of background staining on paraformaldehyde fixed/saponin-permeabilized mouse or human cells for flow cytometric analysis.
This pre-titered antibody solution does not contain a cell permeabilized agent. It is necessary to include a cell permeabilization agent when using the pre-titered antibody solution to stain fixed and permeabilized cells. Perm/Wash™ Buffer (Cat. No. 554723) contains the permeabilization agent saponin and is useful for this purpose as described in the USAGE section.
USAGE
1. Resuspend 1x10e6 cells fixed and permeabilized cells in 20 µl of the pre-titered antibody solution and 30 µl of 1X Perm/Wash™ Buffer (Cat. No. 554723).
2. Incubate the cell suspension for 15 minutes (at RT or 4°C).
3. Wash twice in 100 µl of 1X Perm/Wash™ Buffer (Cat. No. 554723).
Bead-based compensation or unmixing controls, such as BD® CompBeads or BD™ SpectraComp™, can be used as surrogates to assess fluorescence spillover when bound to fluorochrome-conjugated antibodies. Although these beads have spectral properties similar to cells, variations in spectral emission may occur, resulting in differing spillover values compared to biological controls. Therefore, it is considered best practice to compare the spillover obtained from cells and bead-based controls when using BD® CompBeads or BD™ SpectraComp™ for the first time, to ensure they are appropriate for the intended application.
Product Notices
- Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
- Source of all serum proteins is from USDA inspected abattoirs located in the United States.
- Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
- Since applications vary, each investigator should titrate the reagent to obtain optimal results.
- For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
- An isotype control should be used at the same concentration as the antibody of interest.
- Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
- For U.S. patents that may apply, see bd.com/patents.
関連製品
The MOPC-21 immunoglobulin is a mouse myeloma protein. The MOPC-21 immunoglobulin was selected as an isotype control following screening for low background on a variety of mouse and human tissues.
Development References (1)
-
Prussin C, Metcalfe DD. Detection of intracytoplasmic cytokine using flow cytometry and directly conjugated anti-cytokine antibodies. J Immunol Methods. 1995; 188(1):117-128. (Biology). View Reference
Please refer to Support Documents for Quality Certificates
Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described
Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims. Comparisons are not made against non-BD technologies, unless otherwise noted.
For Research Use Only. Not for use in diagnostic or therapeutic procedures.