Old Browser
Looks like you're visiting us from {countryName}.
Would you like to stay on the current country site or be switched to your country?
监管状态图例
未经BD明确书面授权,严禁使用未经许可的任何商品。
准备和存储
推荐的实验流程
Put all BD® AbSeq Reagents to be pooled into a Latch Rack for 500 µL Tubes (Thermo Fisher Scientific Cat. No. 4900). Arrange the tubes so that they can be easily uncapped and re-capped with an 8-Channel Screw Cap Tube Capper (Thermo Fisher Scientific Cat. No. 4105MAT) and the reagents aliquoted with a multi-channel pipette. BD® AbSeq tubes should be centrifuged for = 30 seconds at 400 g to ensure removal of any contents in the cap/tube threads prior to the first opening.
Please refer to the following CITE-Seq protocols for additional staining instructions:
• Single Cell Labelling with BD® AbSeq Ab-Oligos (1 to 40-plex) (Doc ID: 23-24262)
• Single-Cell Labeling with BD® AbSeq Ab-Oligos (41 to 100 plex) (Doc ID: 23-22314)
• Single Cell Labelling with BD® Single-Cell Multiplexing Kits and BD® AbSeq Ab-Oligos (1 to 40 plex) (Doc ID:23-21339)
• Single-Cell Labeling with BD® Single-Cell Multiplexing Kits and BD® AbSeq Ab-Oligos (41 to 100 plex) (Doc ID: 23-22354)
• Single-Cell Labeling with BD® Flex Single-Cell Multiplexing Kits and BD® AbSeq Ab-Oligos (1 plex to 100 plex) (Doc ID:23-24312)
Sequencing reference files can be made using the BD® AbSeq Panel Generator (https://abseq-ref-gen.genomics.bd.com/).
Use standard laboratory safety protocols. Read and understand the safety data sheets (SDSs) before handling chemicals. To obtain SDSs, go to regdocs.bd.com or contact BD Biosciences technical support at scomix@bd.com.
Warning: All biological specimens and materials contacting them are considered biohazardous. Handle as if capable of transmitting infection and dispose of with proper precautions in accordance with federal, state, and local regulations. Never pipette by mouth. Wear suitable protective clothing, eyewear, and gloves.
商品通知
- This reagent has been pre-diluted for use at the recommended volume per test. Typical use is 2 μl for 1 × 10^6 cells in a 200-μl staining reaction. For best results, close caps securely after use and before storage.
- Please refer to https://www.bdbiosciences.com/en-us/resources/protocols/single-cell-multiomics for technical protocols.
- Source of all serum proteins is from USDA inspected abattoirs located in the United States.
- The production process underwent stringent testing and validation to assure that it generates a high-quality conjugate with consistent performance and specific binding activity. However, verification testing has not been performed on all conjugate lots.
- Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
- Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing. Follow state and local guidelines when disposing of hazardous waste.
- For U.S. patents that may apply, see bd.com/patents.
The G155-178 clone has an unknown specificity. Trinitrophenol (TNP), the immunogen, is a hapten not expressed on human, mouse, rat or non-human primate cells. In the absence of specific binding, this antibody may bind non-specifically to immunoglobulin Fc receptors. The immunoglobulin secreted by the G155-178 hybridoma was selected as a mouse IgG2a, κ isotype control following screening for low background binding on a variety of mouse and human tissues.
The antibody was conjugated to an oligonucleotide that contains an antibody clone-specific barcode (ABC) flanked by a poly-A tail on the 3' end and a PCR handle (PCR primer binding site) on the 5' end. The ABC for this antibody was designed to be used with other BD® AbSeq oligonucleotides conjugated to other antibodies. All AbSeq ABC sequences were selected in silico to be unique from human and mouse genomes, have low predicted secondary structure, and have high Hamming distance within the BD® AbSeq portfolio, to allow for sequencing error correction and unique mapping. The poly-A tail of the oligonucleotide allows the ABC to be captured by the BD Rhapsody™ system. The 5' PCR handle allows for efficient sequencing library generation for various sequencing platforms.
NOTE: The BD Rhapsody™ Single-Cell Analysis System must be used with the BD Rhapsody™ Express Instrument or BD Rhapsody™ HT Xpress Instrument.
No Citations are available for this Product
Please refer to Support Documents for Quality Certificates
Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described
Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims. Comparisons are not made against non-BD technologies, unless otherwise noted.
For Research Use Only. Not for use in diagnostic or therapeutic procedures.