-
Reagents
- Flow Cytometry Reagents
-
蛋白质印迹试剂
- 免疫分析 试剂
-
Single-Cell Multiomics Reagents
- BD® AbSeq Assay
- BD Rhapsody™ 附件试剂盒
- BD® Single-Cell Multiplexing Kit
- BD Rhapsody™ TCR/BCR Next Multiomic Assays
- BD Rhapsody™ Targeted mRNA Kits
- BD Rhapsody™ Whole Transcriptome Analysis (WTA) Amplification Kit
- BD® OMICS-Guard Sample Preservation Buffer
- BD Rhapsody™ ATAC-Seq Assays
- BD® OMICS-One Protein Panels
- BD OMICS-One™ WTA Next Assay
-
Functional Assays
-
显微成像试剂
-
Cell Preparation and Separation Reagents
Old Browser
Looks like you're visiting us from {countryName}.
Would you like to stay on the current location or be switched to your location?
BD Pharmingen™ Recombinant Mouse MCP-1
监管状态图例
未经BD明确书面授权,严禁使用未经许可的任何商品。
Product Details
描述
Mouse monocyte chemoattractant protein-1 (MCP-1), previously termed JE, is a member of the CC chemokine family and a homolog of human MCP-1. MCP-1 is expressed by a variety of cell types including monocyte/macrophages, endothelial cells and mesangial cells. MCP-1 has chemoattractant activity on monocytes, lymphocytes and basophils but is not active on neutrophils. Recombinant mouse MCP-1 (MN 554590) is supplied as a frozen liquid comprised of 0.22 µm sterile-filtered aqueous buffered solution (pH 7.2) and containing 1.29 mg/mL bovine serum albumin, with no preservatives. Recombinant mouse MCP-1 is > 95% pure as determined by SDS-PAGE, and an absorbance assay based on the Beers-Lambert law. The endotoxin level is ≤ 0.1 ng per µg of mouse MCP-1, as measured in a chromogenic LAL assay.
准备和存储标题文本
推荐的实验流程
Upon initial thawing, recombinant mouse MCP-1 (MN 554590) should be aliquoted into polypropylene microtubes and frozen at -80°C for future use. Alternatively, the product can be diluted in sterile neutral buffer containing not less than 0.5 - 10 mg/mL carrier protein, such as human or bovine serum albumin, aliquoted and stored at -80°C. For in vitro biological assay use, carrier-protein concentrations of 0.5 - 1 mg/mL are recommended. For use as an ELISA standard, carrier-protein concentrations of 5 - 10 mg/mL are recommended. Failure to add carrier protein or store at indicated temperatures may result in a loss of activity. Carrier proteins should be pre-screened for possible affects in each investigator's experimental system. Carrier proteins may have an undesired influence on experimental results due to toxicity, high endotoxin levels or possible blocking activity.
ELISA Standard: Recombinant mouse MCP-1 (MN 554590) can be useful as a quantitative standard for measuring mouse MCP-1 protein levels using sandwich ELISA with the purified 2H5 antibody (Cat. No. 551217) as a capture antibody and the biotinylated 4E2/MCP antibody (Cat. No. 554444) as the detection antibody. To obtain linear standard curves, investigators may want to consider using doubling dilutions of recombinant mouse MCP-1 from 4000-30 pg/mL to be included for each ELISA plate. For measuring mouse MCP-1 in serum or plasma, investigators are highly encouraged to use the BD OptEIA™ Mouse MCP-1 Set (Cat. No. 555260).
Bioassay: Investigators are advised that the Bioassay application is not routinely tested for this material and are highly encouraged to both titrate this material and include appropriate controls in relevant experiments. An activity range encompassing an ED50 = 50 - 800 ng/mL has previously been reported using THP-1 as indicator cells utilizing a calcium flux assay.
商品通知
- Since applications vary, each investigator should titrate the reagent to obtain optimal results.
- Source of all serum proteins is from USDA inspected abattoirs located in the United States.
- Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
配套商品
Please refer to Support Documents for Quality Certificates
Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described
Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims. Comparisons are not made against non-BD technologies, unless otherwise noted.
For Research Use Only. Not for use in diagnostic or therapeutic procedures.