Reagents
- Flow Cytometry Reagents
-
蛋白质印迹试剂
- 免疫分析 试剂
-
Single-Cell Multiomics Reagents
- BD® AbSeq Assay
- BD Rhapsody™ 附件试剂盒
- BD® Single-Cell Multiplexing Kit
- BD Rhapsody™ TCR/BCR Next Multiomic Assays
- BD Rhapsody™ Targeted mRNA Kits
- BD Rhapsody™ Whole Transcriptome Analysis (WTA) Amplification Kit
- BD® OMICS-Guard Sample Preservation Buffer
- BD Rhapsody™ ATAC-Seq Assays
- BD® OMICS-One Protein Panels
-
Functional Assays
-
显微成像试剂
-
Cell Preparation and Separation Reagents
-
- BD® AbSeq Assay
- BD Rhapsody™ 附件试剂盒
- BD® Single-Cell Multiplexing Kit
- BD Rhapsody™ TCR/BCR Next Multiomic Assays
- BD Rhapsody™ Targeted mRNA Kits
- BD Rhapsody™ Whole Transcriptome Analysis (WTA) Amplification Kit
- BD® OMICS-Guard Sample Preservation Buffer
- BD Rhapsody™ ATAC-Seq Assays
- BD® OMICS-One Protein Panels
- China (Chinese)
-
改变地点/语言
Old Browser
Looks like you're visiting us from {countryName}.
Would you like to stay on the current location or be switched to your location?
BD Pharmingen™ Recombinant Rat IL-6
监管状态图例
未经BD明确书面授权,严禁使用未经许可的任何商品。
Product Details
描述
Interleukin-6 (IL-6, aka IFN-β2, BSF-2, and HPGF) is a multifunctional cytokine which regulates immune responses, acute-phase reactions and hematopoiesis. Reported cellular targets for IL-6 action are hepatocytes, B and T lymphocytes, neurons, tumor cells and multi-potent hematopoietic cells. Recombinant rat IL-6 (Cat. No. 557008) is supplied as a frozen liquid comprised of 0.22 μm sterile-filtered aqueous buffered solution, glycerol and bovine serum albumin, with no preservatives. Recombinant rat IL-6 is ≥ 95% pure as determined by SDS-PAGE and an absorbance assay based on the Beers-Lambert law. The endotoxin level is ≤ 0.1 ng per μg of rat IL-6, as measured in a chromogenic LAL assay.
准备和存储标题文本
推荐的实验流程
Upon initial thawing, recombinant rat IL-6 (Cat. No. 557008) should be aliquoted into polypropylene microtubes and frozen at -80°C for future use. Alternatively, the product can be diluted in sterile neutral buffer containing not less than 0.5 – 1.0 mg/mL carrier protein, such as human or bovine serum albumin, aliquoted and stored at -80°C. Failure to add carrier protein or store at the indicated temperatures may result in a loss of activity. Carrier proteins should be pre-screened for possible effects in an appropriate experimental system. Carrier proteins may have an undesired influence on experimental results due to toxicity, high endotoxin levels or possible blocking activity.
ELISA Standard: Rat IL-6 is useful as a quantitative standard for measuring rat IL-6 protein levels in a IL-6 specific sandwich ELISA, with the purified C3-4 antibody (Cat. No. 550644) as a capture antibody and the biotinylated G307-2 antibody (Cat. No. 550642) as the detection antibody. This ELISA pair is recommended primarily for measuring cytokine from experimental cell culture systems, not for assay of serum or plasma samples. For measuring rat IL-6 in serum or plasma, the BD OptEIA™ Rat IL-6 Set (Cat. No. 550319) is specially formulated and recommended.
Bioassay: Investigators are advised that the Bioassay application is not routinely tested for this material and are highly encouraged to both titrate this material and include appropriate controls in relevant experiments. An activity range of 1.0 - 6.6 x 10^7 units/mg, encompassing an ED50= 0.15 - 1.0 ng/mL, has previously been reported using NFS-60 indicator cells for proliferation, with a unit defined as the amount of material needed to stimulate a half-maximal response at cytokine saturation.
商品通知
- Since applications vary, each investigator should titrate the reagent to obtain optimal results.
- Source of all serum proteins is from USDA inspected abattoirs located in the United States.
- Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
配套商品
Please refer to Support Documents for Quality Certificates
Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described
Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims. Comparisons are not made against non-BD technologies, unless otherwise noted.
For Research Use Only. Not for use in diagnostic or therapeutic procedures.