-
Reagents
- Flow Cytometry Reagents
-
蛋白质印迹试剂
- 免疫分析 试剂
-
Single-Cell Multiomics Reagents
- BD® AbSeq Assay
- BD Rhapsody™ 附件试剂盒
- BD® Single-Cell Multiplexing Kit
- BD Rhapsody™ TCR/BCR Next Multiomic Assays
- BD Rhapsody™ Targeted mRNA Kits
- BD Rhapsody™ Whole Transcriptome Analysis (WTA) Amplification Kit
- BD® OMICS-Guard Sample Preservation Buffer
- BD Rhapsody™ ATAC-Seq Assays
- BD® OMICS-One Protein Panels
-
Functional Assays
-
显微成像试剂
-
Cell Preparation and Separation Reagents
Old Browser
Looks like you're visiting us from {countryName}.
Would you like to stay on the current location or be switched to your location?
BD Pharmingen™ Recombinant Human IL-12 p40
监管状态图例
未经BD明确书面授权,严禁使用未经许可的任何商品。
Product Details
描述
Interleukin-12 (IL-12) is a potent regulator of cell-mediated immune responses. Biologically active IL-12 is secreted by activated B lymphocytes and macrophages as a 70 kD heterodimeric glycoprotein comprised of disulfide-bonded 35 kD (p35) and 40 kD (p40) subunits. The IL-12 p40 monomer shares amino acid sequence homology with the IL-6 receptor. It has been reported that activated PBMC produce a many fold excess of IL-12 p40 monomer over the bioactive p70 heterodimer. The IL-12 p40 monomer has been reported to inhibit binding of IL-12 p70 to the IL-12 receptor, but with 20X less effectiveness than the IL-12 p70 homodimer.
Recombinant human IL-12 p40 protein was purified by immunoaffinity chromatography. The recombinant is > 95% pure, as detemined by SDS-PAGE, and an absorbance assay based on the Beers-Lambert law. The endotoxin level is ≤ 0.1 ng/µg of human IL-12 p40, as measued in a chromogenic LAL assay.
This recombinant protein is routinely tested by ELISA. Other applications were tested at BD Biosciences Pharmingen during product development only or reported in the literature.
准备和存储标题文本
Recombinant human IL-12 p40 monomer is supplied as a frozen liquid comprised of 0.22 μm sterile-filtered aqueous buffered solution (pH 7.4) and containing at least 1.0 mg/ml biotechnology grade, low endotoxin bovine serum albumin, with no preservatives.Upon initial thawing the product should be aliquoted into polypropylene microtubes and frozen at -80˚C for future use. Alternatively, the product can be diluted in sterile neutral buffer containing not less than 0.5 – 1.0 mg/ml carrier protein** such as human or bovine albumin, aliquoted and stored at -80˚C. Failure to add carrier protein or store at indicated temperatures may result in a loss of activity.
推荐的实验流程
ELISA Standard: This recombinant human IL-12 p40 protein is useful as a quantitative standard for an IL-12 p40 sandwich ELISA. For this assay, the purified C8.3 capture antibody (Cat. No. 551227) can be paired with the biotinylated C8.6 detection antibody (Cat. No. 554660). For specific methodology please visit the protocols sections or the chapter on ELISA in the Immune Function Handbook, both of which are posted on our web site, www.bdbiosciences.com.
Note 1: The ELISA antibody pair is recommended primarily for measuring cytokine from experimental cell culture systems. These ELISA reagents are not recommended for assay of serum or plasma samples. For measuring human IL-12p40 in serum or plasma our Human IL-12p40 OptEIA™ Set (Cat. No. 555171 ) or OptEIA Kit II (Cat. No. 551116) is specially formulated and recommended.
Note 2: Carrier proteins** should be pre-screened for possible effects in an appropriate experimental system. Carrier proteins may effect experimental results due to toxicity, high endotoxin levels or possible blocking activity.
商品通知
- Since applications vary, each investigator should titrate the reagent to obtain optimal results.
- Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
- Source of all serum proteins is from USDA inspected abattoirs located in the United States.
Please refer to Support Documents for Quality Certificates
Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described
Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims. Comparisons are not made against non-BD technologies, unless otherwise noted.
For Research Use Only. Not for use in diagnostic or therapeutic procedures.