Skip to main content Skip to navigation
BV421 Mouse Anti-Human HLA-A
BV421 Mouse Anti-Human HLA-A
Multiparameter flow cytometric analysis of HLA-A expression on human peripheral blood leucocyte populations. Human whole blood was stained with either BD Horizon™BV421 Mouse IgG1, κ Isotype Control (Cat. No. 562438; Left Plot) or BD Horizon™BV421 Mouse Anti-Human HLA-A antibody (Cat. No. 568024/568025; Right Plot). The erythrocytes were lysed with BD FACS™ Lysing Solution (Cat. No. 349202). The bivariate pseudocolor density plot showing the correlated expression of HLA-A (or Ig Isotype control staining) versus side light-scatter (SSC-A) signals was derived from gated events with the forward and side light-scatter characteristics of intact leucocyte populations. Flow cytometry and data analysis were performed using a BD LSRFortessa™ X-20 Cell Analyzer System and FlowJo™ software.
Multiparameter flow cytometric analysis of HLA-A expression on human peripheral blood leucocyte populations. Human whole blood was stained with either BD Horizon™BV421 Mouse IgG1, κ Isotype Control (Cat. No. 562438; Left Plot) or BD Horizon™BV421 Mouse Anti-Human HLA-A antibody (Cat. No. 568024/568025; Right Plot). The erythrocytes were lysed with BD FACS™ Lysing Solution (Cat. No. 349202). The bivariate pseudocolor density plot showing the correlated expression of HLA-A (or Ig Isotype control staining) versus side light-scatter (SSC-A) signals was derived from gated events with the forward and side light-scatter characteristics of intact leucocyte populations. Flow cytometry and data analysis were performed using a BD LSRFortessa™ X-20 Cell Analyzer System and FlowJo™ software.
商品详情
Down Arrow Up Arrow


BD Horizon™
HLA-A; HLAA; MHC class I antigen HLA-A heavy chain
Human (QC Testing)
Mouse IgG1, κ
Human Peripheral Blood Lymphocytes
Flow cytometry (Routinely Tested)
5 µl
Aqueous buffered solution containing BSA and ≤0.09% sodium azide.
RUO


准备和存储

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated to the dye under optimum conditions and unconjugated antibody and free dye were removed.

推荐的实验流程

BD® CompBeads can be used as surrogates to assess fluorescence spillover (Compensation). When fluorochrome conjugated antibodies are bound to BD® CompBeads, they have spectral properties very similar to cells.  However, for some fluorochromes there can be small differences in spectral emissions compared to cells, resulting in spillover values that differ when compared to biological controls. It is strongly recommended that when using a reagent for the first time, users compare the spillover on cells and BD® CompBeads to ensure that BD® CompBeads are appropriate for your specific cellular application.

For optimal and reproducible results, BD Horizon Brilliant™ Stain Buffer should be used anytime BD Horizon Brilliant™ dyes are used in a multicolor flow cytometry panel. Fluorescent dye interactions may cause staining artifacts which may affect data interpretation. The BD Horizon Brilliant™ Stain Buffer was designed to minimize these interactions. When BD Horizon Brilliant™ Stain Buffer is used in in the multicolor panel, it should also be used in the corresponding compensation controls for all dyes to achieve the most accurate compensation. For the most accurate compensation, compensation controls created with either cells or beads should be exposed to BD Horizon Brilliant™ Stain Buffer for the same length of time as the corresponding multicolor panel. More information can be found in the Technical Data Sheet of the BD Horizon Brilliant™ Stain Buffer (Cat. No. 563794/566349) or the BD Horizon Brilliant™ Stain Buffer Plus (Cat. No. 566385).

商品通知

  1. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  2. Source of all serum proteins is from USDA inspected abattoirs located in the United States.
  3. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  4. This reagent has been pre-diluted for use at the recommended Volume per Test. We typically use 1 × 10^6 cells in a 100-µl experimental sample (a test).
  5. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  6. An isotype control should be used at the same concentration as the antibody of interest.
  7. BD Horizon Brilliant Violet 421 is covered by one or more of the following US patents: 8,158,444; 8,362,193; 8,575,303; 8,354,239.
  8. BD Horizon Brilliant Stain Buffer is covered by one or more of the following US patents: 8,110,673; 8,158,444; 8,575,303; 8,354,239.
  9. Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
  10. Pacific Blue™ is a trademark of Life Technologies Corporation.
568026 Rev. 1
抗体详情
Down Arrow Up Arrow
1082C5

The 1082C5 monoclonal antibody (also known as clone 108-2C5) recognizes a shared antigenic determinant present on the extracellular region of Human Leukocyte Antigen-A (HLA-A) heavy chains encoded by a limited number of different HLA-A alleles (HLA-A2, -A3, -A28, -A29, -A30, -A31 and -A33). HLA-A antigens belong to the major histocompatibility complex (MHC) of class I antigens along with HLA-B and HLA-C antigens. HLA class I molecules are heterodimers comprised of an ~40-45 kDa, highly polymorphic transmembrane α heavy chain that is a type I glycoprotein which is noncovalently-associated with an invariant β2-microglobulin (β2m) light chain. The N-terminal extracellular region of the HLA class I heavy chain is comprised of three domains (α1, α2, and α3). The α1 and α2 domains form a closed antigen-binding groove that accommodates 8-10 aa-peptide antigens. β2m non-covalently associates with the α3 heavy chain domain and promotes HLA class I stability. The intralocus HLA-A determinant recognized by the 108-2C5 antibody reportedly involves amino acids residues 76-80 of the HLA-A α1 domain. HLA-A antigens are normally expressed on all nucleated cells. These molecules play central roles in the MHC class I-restricted presentation and cross-presentation of antigens and the regulation of NK and T cell-mediated cytotoxicity that are involved in immune responses to pathogens and tumors as well as tissue allotransplantation.

568026 Rev. 1
格式详情
Down Arrow Up Arrow
BV421
The BD Horizon Brilliant Violet™ 421 (BV421) Dye is part of the BD Horizon Brilliant Violet™ family of dyes. This polymer-technology based dye has an excitation maximum (Ex Max) of 407-nm and an emission maximum (Em Max) at 423-nm. Driven by BD innovation, BV421 is designed to be excited by the violet laser (405-nm) and detected using an optical filter centered near 420-nm (e.g., a 431/28-nm or 450/50-nm bandpass filter). BV421 is an ideal alternative for V450 as it is approximately ten times brighter with less spillover into the BV510/V500 detector. Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
altImg
BV421
Violet 405 nm
407 nm
423 nm
568026 Rev.1
报价单和参考
Down Arrow Up Arrow

研发参考 (6)

  1. Bardi MS, Jarduli LR, Jorge AJ, et al. HLA-A, B and DRB1 allele and haplotype frequencies in volunteer bone marrow donors from the north of Parana State. Rev Bras Hematol Hemoter. 2012; 34(1):25-30. (Biology). 查看参考
  2. Guerreiro-Cacais AO, Uzunel M, Levitskaya J, Levitsky V. Inhibition of heavy chain and beta2-microglobulin synthesis as a mechanism of major histocompatibility complex class I downregulation during Epstein-Barr virus replication.. J Virol. 2007; 81(3):1390-400. (Clone-specific: Flow cytometry). 查看参考
  3. Hühn MH, Hultcrantz M, Lind K, Ljunggren HG, Malmberg KJ, Flodström-Tullberg M. IFN-gamma production dominates the early human natural killer cell response to Coxsackievirus infection.. Cell Microbiol. 2008; 10(2):426-36. (Clone-specific: Flow cytometry). 查看参考
  4. Llano M, Gumá M, Ortega M, Angulo A, López-Botet M. Differential effects of US2, US6 and US11 human cytomegalovirus proteins on HLA class Ia and HLA-E expression: impact on target susceptibility to NK cell subsets.. Eur J Immunol. 2003; 33(10):2744-54. (Clone-specific: Flow cytometry). 查看参考
  5. Lozano F, Santos-Aguado J, Borche L, et al. Identification of the amino acid residues defining an intralocus determinant in the alpha 1 domain of HLA-A molecules.. Immunogenetics. 1989; 30(1):50-3. (Clone-specific: Blocking, Flow cytometry, Immunoprecipitation, Radioimmunoassay). 查看参考
  6. Ryschich E, Cebotari O, Fabian OV, et al. Loss of heterozygosity in the HLA class I region in human pancreatic cancer.. Tissue Antigens. 2004; 64(6):696-702. (Clone-specific: Immunohistochemistry). 查看参考
查看所有文件 (6) 查看更少内容
568026 Rev. 1

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.