Skip to main content Skip to navigation
RB780 Rat Anti-Mouse CD26
RB780 Rat Anti-Mouse CD26
Flow cytometric analysis using BD OptiBuild™ RB780 Rat Anti-Mouse CD26 antibody (Cat. No. 755929; solid line histogram) on viable C57BL/6 mouse splenocytes, with corresponding Isotype Control (Cat. No. 568698; dotted line histogram). Flow cytometry was performed using a BD LSRFortessa™ X-20 Flow Cytometer System.
Flow cytometric analysis using BD OptiBuild™ RB780 Rat Anti-Mouse CD26 antibody (Cat. No. 755929; solid line histogram) on viable C57BL/6 mouse splenocytes, with corresponding Isotype Control (Cat. No. 568698; dotted line histogram). Flow cytometry was performed using a BD LSRFortessa™ X-20 Flow Cytometer System.
商品详情
Down Arrow Up Arrow


BD OptiBuild™
Cd26; Dpp4; dipeptidylpeptidase 4; THAM, DPP IV
Mouse (Tested in Development)
Rat LOU, also known as Louvain, LOU/C, LOU/M IgG2a, κ
Cell-surface molecules solubilized from BALB/c mouse thymocytes
Flow cytometry (Qualified)
0.2 mg/ml
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


准备和存储

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated to the dye under optimum conditions that minimize unconjugated dye and antibody.

推荐的实验流程

BD® CompBeads can be used as surrogates to assess fluorescence spillover (compensation). When fluorochrome conjugated antibodies are bound to BD® CompBeads, they have spectral properties very similar to cells. However, for some fluorochromes there can be small differences in spectral emissions compared to cells, resulting in spillover values that differ when compared to biological controls. It is strongly recommended that when using a reagent for the first time, users compare the spillover on cells and BD® CompBeads to ensure that BD® CompBeads are appropriate for your specific cellular application.

商品通知

  1. When using high concentrations of antibody, background binding of this dye to erythroid fragments produced by ammonium chloride-based lysis, such as with BD Pharm Lyse™ Lysing Buffer (Cat. No. 555899), has been observed when the antibody conjugate was present during the lysis procedure. This may cause nonspecific staining of target cells, such as leukocytes, which have bound the resulting erythroid fragments. This background can be mitigated by any of the following: titrating the antibody conjugate to a lower concentration, fixing samples with formaldehyde, or removing erythrocytes before staining (eg, gradient centrifugation or pre-lysis with wash). This background has not been observed when cells were lysed with BD FACS™ Lysing Solution (Cat. No. 349202) after staining.
  2. Researchers should determine the optimal concentration of this reagent for their individual applications.
  3. The production process underwent stringent testing and validation to assure that it generates a high-quality conjugate with consistent performance and specific binding activity. However, verification testing has not been performed on all conjugate lots.
  4. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  5. Please observe the following precautions: Absorption of visible light can significantly alter the energy transfer occurring in any tandem fluorochrome conjugate; therefore, we recommend that special precautions be taken (such as wrapping vials, tubes, or racks in aluminum foil) to prevent exposure of conjugated reagents, including cells stained with those reagents, to room illumination.
  6. An isotype control should be used at the same concentration as the antibody of interest.
  7. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  8. Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
  9. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  10. Since applications vary, each investigator should titrate the reagent to obtain optimal results.
  11. Cy is a trademark of Global Life Sciences Solutions Germany GmbH or an affiliate doing business as Cytiva.
755929 Rev. 2
抗体详情
Down Arrow Up Arrow
H194-112

The H194-112 monoclonal antibody specifically binds to CD26, which is also known as, Thymocyte-activating molecule (THAM), or dipeptidyl peptidase IV (DPP IV, Dpp4).  CD26 is a ~220- kDa dimer formed of identical type-II transmembrane core polypeptides which undergo variable post-translational modifications.  It is a multi-functional molecule with both ectopeptidase and signal-transducing activities.  Studies with specific DPP IV inhibitors suggest that the enzymatic activity is involved in the mediation of T-cell activation events.  The expression of CD26 is developmentally regulated in the thymus.  Resting lymphoid cells of the bone marrow and peripheral B and T lymphocytes express low levels of CD26; bone-marrow and peritoneal myeloid cells do not.  CD26 is also found on epithelial cells in the kidney, liver, small intestine, and lung.  Cross-linked H194-112 mAb induces proliferation of immature and mature thymocytes in the presence of either IL-1 plus IL-2 or PMA;  addition of IL-2 or IL-4 to PMA further enhances the activation.

755929 Rev. 2
格式详情
Down Arrow Up Arrow
RB780
The BD Horizon RealBlue™ 780 (RB780) Dye is part of the BD family of blue dyes. It is a tandem fluorochrome with an excitation maximum (Ex Max) at 498-nm and an emission maximum (Em Max) at 781-nm. Driven by BD innovation, RB780 can be used on both spectral and conventional cytometers and is designed to be excited by the Blue laser (488-nm) with minimal excitation by the 561-nm Yellow-Green laser. For conventional instruments equipped with a Blue laser (488-nm), RB780 can be used as an alternative to PE-Cy7 and we recommend using an optical filter centered near 780-nm (eg, a 780/60-nm bandpass filter). For spectral instruments equipped with a Blue laser (488-nm), it can be used in conjunction with PE-Cy7. RB780 is on average brighter than PE-Cy7 and has minimal spillover into Yellow-Green detectors.
altImg
RB780
Blue 488 nm
498 nm
781 nm
755929 Rev.2
报价单和参考
Down Arrow Up Arrow
View product citations for antibody "755929" on CiteAb

研发参考 (7)

  1. Fleischer B. CD26: a surface protease involved in T-cell activation. Immunol Today. 1994; 15(4):180-184. (Biology). 查看参考
  2. Gorvel JP, Vivier I, Naquet P, Brekelmans P, Rigal A, Pierres M. Characterization of the neutral aminopeptidase activity associated to the mouse thymocyte-activating molecule. J Immunol. 1990; 144(8):2899-2907. (Biology). 查看参考
  3. Marguet D, Bernard AM, Vivier I, Darmoul D, Naquet P, Pierres M. cDNA cloning for mouse thymocyte-activating molecule. A multifunctional ecto-dipeptidyl peptidase IV (CD26) included in a subgroup of serine proteases. J Biol Chem. 1992; 267(4):2200-2208. (Biology). 查看参考
  4. Naquet P, MacDonald HR, Brekelmans P. A novel T cell-activating molecule (THAM) highly expressed on CD4-CD8- murine thymocytes. J Immunol. 1988; 141(12):4101-4109. (Immunogen: Activation). 查看参考
  5. Naquet P, Vivier I, Gorvel JP. Activation of mouse T lymphocytes by a monoclonal antibody to a developmentally regulated surface aminopeptidase (THAM). Immunol Rev. 1989; 111:177-193. (Clone-specific: Activation). 查看参考
  6. Reinhold D, Bank U, Buhling F. Inhibitors of dipeptidyl peptidase IV (DP IV, CD26) induces secretion of transforming growth factor-beta 1 (TGF-beta 1) in stimulated mouse splenocytes and thymocytes. Immunol Lett. 1997; 58(1):29-35. (Biology: Activation). 查看参考
  7. Vivier I, Marguet D, Naquet P . Evidence that thymocyte-activating molecule is mouse CD26 (dipeptidyl peptidase IV). J Immunol. 1988; 147(2):447-454. (Biology). 查看参考
查看所有文件 (7) 查看更少内容
755929 Rev. 2

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.