-
Reagents
- Flow Cytometry Reagents
-
蛋白质印迹试剂
- 免疫分析 试剂
-
Single-Cell Multiomics Reagents
- BD® AbSeq Assay
- BD Rhapsody™ 附件试剂盒
- BD® Single-Cell Multiplexing Kit
- BD Rhapsody™ TCR/BCR Next Multiomic Assays
- BD Rhapsody™ Targeted mRNA Kits
- BD Rhapsody™ Whole Transcriptome Analysis (WTA) Amplification Kit
- BD OMICS-Guard™ Sample Preservation Buffer
- BD Rhapsody™ ATAC-Seq Assays
- BD® OMICS-One Protein Panels
- BD OMICS-One™ WTA Next Assay
-
Functional Assays
-
显微成像试剂
-
Cell Preparation and Separation Reagents
Old Browser
Looks like you're visiting us from {countryName}.
Would you like to stay on the current location or be switched to your location?
BD Horizon™ BV786 Mouse Anti-Mouse RORγt
克隆 Q31-378 (RUO)
Multicolor flow cytometric analysis of RORγt expression in mouse thymocytes. BALB/c mouse thymocytes were stained with APC Rat Anti-Mouse CD4 (Cat. No. 553051/561091) and FITC Rat Anti-Mouse CD8a (Cat. No. 553031/553030/561966) antibodies, and fixed and permeabilized using the BD Pharmingen™ Transcription Factor Buffer Set (Cat. No. 562574/562725). The fixed and permeabilized cells were then stained with BD Horizon™ BV786 Mouse Anti-Mouse RORγt antibody (Cat. No. 564723). The overlapping histograms showing RORγt expression were derived from CD4+CD8- single-positive (dashed line histogram) or CD4+CD8+ double-positive (solid line histogram) gated events with the forward and side light-scatter characteristics of intact thymocytes. Flow cytometric analysis was performed using a BD LSRFortessa™ Cell Analyzer System.
Multicolor flow cytometric analysis of RORγt expression in mouse thymocytes. BALB/c mouse thymocytes were stained with APC Rat Anti-Mouse CD4 (Cat. No. 553051/561091) and FITC Rat Anti-Mouse CD8a (Cat. No. 553031/553030/561966) antibodies, and fixed and permeabilized using the BD Pharmingen™ Transcription Factor Buffer Set (Cat. No. 562574/562725). The fixed and permeabilized cells were then stained with BD Horizon™ BV786 Mouse Anti-Mouse RORγt antibody (Cat. No. 564723). The overlapping histograms showing RORγt expression were derived from CD4+CD8- single-positive (dashed line histogram) or CD4+CD8+ double-positive (solid line histogram) gated events with the forward and side light-scatter characteristics of intact thymocytes. Flow cytometric analysis was performed using a BD LSRFortessa™ Cell Analyzer System.
Multicolor flow cytometric analysis of RORγt expression in mouse thymocytes. BALB/c mouse thymocytes were stained with APC Rat Anti-Mouse CD4 (Cat. No. 553051/561091) and FITC Rat Anti-Mouse CD8a (Cat. No. 553031/553030/561966) antibodies, and fixed and permeabilized using the BD Pharmingen™ Transcription Factor Buffer Set (Cat. No. 562574/562725). The fixed and permeabilized cells were then stained with BD Horizon™ BV786 Mouse Anti-Mouse RORγt antibody (Cat. No. 564723). The overlapping histograms showing RORγt expression were derived from CD4+CD8- single-positive (dashed line histogram) or CD4+CD8+ double-positive (solid line histogram) gated events with the forward and side light-scatter characteristics of intact thymocytes. Flow cytometric analysis was performed using a BD LSRFortessa™ Cell Analyzer System.
监管状态图例
未经BD明确书面授权,严禁使用未经许可的任何商品。
准备和存储
推荐的实验流程
For optimal and reproducible results, BD Horizon Brilliant™ Stain Buffer should be used anytime BD Horizon Brilliant™ dyes are used in a multicolor flow cytometry panel. Fluorescent dye interactions may cause staining artifacts which may affect data interpretation. The BD Horizon Brilliant Stain Buffer was designed to minimize these interactions. When BD Horizon Brilliant Stain Buffer is used in in the multicolor panel, it should also be used in the corresponding compensation controls for all dyes to achieve the most accurate compensation. For the most accurate compensation, compensation controls created with either cells or beads should be exposed to BD Horizon Brilliant Stain Buffer for the same length of time as the corresponding multicolor panel. More information can be found in the Technical Data Sheet of the BD Horizon Brilliant Stain Buffer (Cat. No. 563794/566349) or the BD Horizon Brilliant Stain Buffer Plus (Cat. No. 566385).
商品通知
- Since applications vary, each investigator should titrate the reagent to obtain optimal results.
- Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
- Source of all serum proteins is from USDA inspected abattoirs located in the United States.
- For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
- BD Horizon Brilliant Stain Buffer is covered by one or more of the following US patents: 8,110,673; 8,158,444; 8,575,303; 8,354,239.
- BD Horizon Brilliant Violet 786 is covered by one or more of the following US patents: 8,110,673; 8,158,444; 8,227,187; 8,455,613; 8,575,303; 8,354,239.
- Cy is a trademark of GE Healthcare.
- Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
配套商品
The Q31-378 monoclonal antibody recognizes mouse RORgamma t (RORγt), an isoform of RORgamma (RORγ). RORγt is a DNA-binding transcription factor that belongs to the ROR/RZR orphan nuclear receptor family. RORγt is expressed exclusively by lymphoid cells including CD4+CD8+ thymocytes, peripheral CD4+ Th17 and CD8+ Tc17 cells, NKT cells and innate lymphoid cells such as lymphoid tissue inducer (LTi) cells. RORγt plays essential roles in thymopoiesis, T cell homeostasis, differentiation of effector T lymphocytes and the development of secondary lymphoid tissues including lymph nodes and Peyer's patches.
研发参考 (11)
-
Baumjohann D, Kageyama R, Clingan JM, et al. The microRNA cluster miR-17 approximately 92 promotes TFH cell differentiation and represses subset-inappropriate gene expression. J Clin Invest. 2013; 14(8):840-848. (Clone-specific: Flow cytometry). 查看参考
-
Bechtel S, Rosenfelder H, Duda A, et al. The full-ORF clone resource of the German cDNA Consortium. BMC Biochem. 2007; 8:399-410. (Biology). 查看参考
-
Eberl G, Littman DR. The role of the nuclear hormone receptor RORgt in the development of lymph nodes and Peyer's patches. Immunol Rev. 2003; 195(195):81-90. (Biology). 查看参考
-
Eberl G, Marmon S, Sunshine MJ, Rennert PD, Choi Y, Littman DR. An essential function for the nuclear receptor RORgamma(t) in the generation of fetal lymphoid tissue inducer cells. Nat Immunol. 2004; 5(1):64-73. (Biology). 查看参考
-
Hamada H, Garcia-Hernandez MdlL, Reome JB, et al. Tc17, a unique subset of CD8 T cells that can protect against lethal influenza challenge. J Immunol. 2009; 182(6):3469-3481. (Biology). 查看参考
-
He YW, Deftos ML, Ojala EW, Bevan MJ. RORgamma t, a novel isoform of an orphan receptor, negatively regulates Fas ligand expression and IL-2 production in T cells. Immunity. 1998; 9(6):797-806. (Biology). 查看参考
-
Hirose T, Smith RJ, Jetten AM. ROR gamma: the third member of ROR/RZR orphan receptor subfamily that is highly expressed in skeletal muscle. Biochim Biophys Acta. 1994; 205(3):1976-1983. (Biology). 查看参考
-
Ivanov, II, McKenzie BS, Zhou L, et al. The orphan nuclear receptor RORgammat directs the differentiation program of proinflammatory IL-17+ T helper cells. Cell. 2006; 126(6):1121-1133. (Biology). 查看参考
-
Medvedev A, Yan ZH, Hirose T, Giguere V, Jetten AM. Cloning of a cDNA encoding the murine orphan receptor RZR/ROR gamma and characterization of its response element. Gene. 1996; 181(1-2):199-206. (Biology). 查看参考
-
Unutmaz D. RORC2: the master of human Th17 cell programming. Eur J Immunol. 2009; 39(6):1452-1455. (Biology). 查看参考
-
van de Pavert SA, Ferreira M, Domingues RG, et al. Maternal retinoids control type 3 innate lymphoid cells and set the offspring immunity. Nature. 2014; 508(7494):123-127. (Clone-specific: Flow cytometry). 查看参考
Please refer to Support Documents for Quality Certificates
Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described
Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims. Comparisons are not made against non-BD technologies, unless otherwise noted.
For Research Use Only. Not for use in diagnostic or therapeutic procedures.