Skip to main content Skip to navigation
BUV661 Mouse Anti-Human CD14
BUV661 Mouse Anti-Human CD14
Multiparameter flow cytometric analysis using BD OptiBuild™ BUV661 Mouse Anti-Human CD14 antibody (Cat. No. 752936) on Human peripheral blood. Flow cytometry was performed using a BD LSRFortessa™ X-20  Flow Cytometer System.
Multiparameter flow cytometric analysis using BD OptiBuild™ BUV661 Mouse Anti-Human CD14 antibody (Cat. No. 752936) on Human peripheral blood. Flow cytometry was performed using a BD LSRFortessa™ X-20  Flow Cytometer System.
商品详情
Down Arrow Up Arrow


BD OptiBuild™
monocyte differentiation antigen CD14; LPS receptor; LPS-R
Human (Tested in Development)
Mouse IgG1, κ
Human Peripheral Blood Monocytes
Flow cytometry (Qualified)
0.2 mg/ml
929
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


准备和存储

The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated to the dye under optimum conditions that minimize unconjugated dye and antibody. Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze.

推荐的实验流程

BD® CompBeads can be used as surrogates to assess fluorescence spillover (compensation).  When fluorochrome conjugated antibodies are bound to BD® CompBeads, they have spectral properties very similar to cells.   However, for some fluorochromes there can be small differences in spectral emissions compared to cells, resulting in spillover values that differ when compared to biological controls.  It is strongly recommended that when using a reagent for the first time, users compare the spillover on cells and BD® CompBeads to ensure that BD® CompBeads are appropriate for your specific cellular application.

For optimal and reproducible results, BD Horizon Brilliant Stain Buffer should be used anytime BD Horizon Brilliant dyes are used in a multicolor flow cytometry panel.  Fluorescent dye interactions may cause staining artifacts which may affect data interpretation.  The BD Horizon Brilliant Stain Buffer was designed to minimize these interactions. When BD Horizon Brilliant Stain Buffer is used in the multicolor panel, it should also be used in the corresponding compensation controls for all dyes to achieve the most accurate compensation. For the most accurate compensation, compensation controls created with either cells or beads should be exposed to BD Horizon Brilliant Stain Buffer for the same length of time as the corresponding multicolor panel. More information can be found in the Technical Data Sheet of the BD Horizon Brilliant Stain Buffer (Cat. No. 563794/566349) or the BD Horizon Brilliant Stain Buffer Plus (Cat. No. 566385).

Note:  When using high concentrations of antibody, background binding of this dye to erythroid cell subsets (mature erythrocytes and precursors) has been observed.  For researchers studying these cell populations, or in cases where light scatter gating does not adequately exclude these cells from the analysis, this background may be an important factor to consider when selecting reagents for panel(s).

商品通知

  1. The production process underwent stringent testing and validation to assure that it generates a high-quality conjugate with consistent performance and specific binding activity. However, verification testing has not been performed on all conjugate lots.
  2. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  3. Since applications vary, each investigator should titrate the reagent to obtain optimal results.
  4. An isotype control should be used at the same concentration as the antibody of interest.
  5. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  6. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  7. Human donor specific background has been observed in relation to the presence of anti-polyethylene glycol (PEG) antibodies, developed as a result of certain vaccines containing PEG, including some COVID-19 vaccines. We recommend use of BD Horizon Brilliant™ Stain Buffer in your experiments to help mitigate potential background. For more information visit https://www.bdbiosciences.com/en-us/support/product-notices.
  8. Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
  9. For U.S. patents that may apply, see bd.com/patents.
752936 Rev. 2
抗体详情
Down Arrow Up Arrow
63D3.rMAb

The 63D3.rMAb is a recombinant monoclonal antibody that specifically recognizes human CD14 which is also known as Monocyte differentiation antigen CD14, Myeloid cell-specific leucine-rich glycoprotein, or LPS Receptor (LPS-R). CD14 is expressed as an ~55 kDa glycophosphatidylinositol (GPI)-linked cell surface glycoprotein. CD14 is highly expressed on most mature monocytes and macrophages, and at lower levels on neutrophils. CD14 is also expressed on some dendritic cells (DC) and Langerhans cells. CD14 binds to bacterial cell wall components including lipopolysaccharide (LPS) bound to lipopolysaccharide-binding protein (LBP). CD14 serves as a co-receptor for certain signaling Toll-like receptors (TLRs) for the cellular detection and response to LPS as well as other pathogen-associated molecular patterns (PAMPs). Ligand-bound CD14 plays a role in stimulating various myeloid cells to produce pro-inflammatory cytokines and mediators and to upregulate the expression of cell surface adhesion molecules. Soluble forms of CD14 (sCD14) are reportedly released by cells into the blood or other bodily fluids. Soluble CD14 can regulate cellular responses to LPS and confer LPS-responsiveness to cells that do not ordinarily express CD14.

752936 Rev. 2
格式详情
Down Arrow Up Arrow
BUV661
The BD Horizon Brilliant™ Ultraviolet 661 (BUV661) Dye is part of the BD Horizon Brilliant™ Ultraviolet family of dyes. This tandem fluorochrome is comprised of a BUV395 donor with an excitation maximum (Ex Max) of 350-nm and an acceptor dye with an emission maximum (Em Max) at 660-nm. BUV661, driven by BD innovation, is designed to be excited by the ultraviolet laser (355-nm) and detected using an optical filter centered near 660-nm (e.g., 670/25 bandpass filter). The acceptor dye can be excited by the Red (628–640-nm) laser resulting in cross-laser excitation and fluorescence spillover. Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
BUV661
Ultraviolet 355 nm
350 nm
660 nm
752936 Rev.2
报价单和参考
Down Arrow Up Arrow
View product citations for antibody "752936" on CiteAb

研发参考 (4)

  1. Devitt A, Moffatt OD, Raykundalia C, Capra JD, Simmons DL, Gregory CD. Human CD14 mediates recognition and phagocytosis of apoptotic cells.. Nature. 1998; 392(6675):505-9. (Clone-specific: Blocking, ELISA, Functional assay, Western blot). 查看参考
  2. Rosenberg SA, Ligler FS, Ugolini V, Lipsky PE. A monoclonal antibody that identifies human peripheral blood monocytes recognizes the accessory- cells required for mitogen-induced T lymphocyte proliferation.. J Immunol. 1981; 126(4):1473-7. (Immunogen: Bioassay, Flow cytometry, Fluorescence activated cell sorting). 查看参考
  3. Ugolini V, Nunez G, Smith RG, Stastny P, Capra JD. Initial characterization of monoclonal antibodies against human monocytes.. Proc Natl Acad Sci USA. 1980; 77(11):6764-8. (Immunogen: Cytotoxicity, Flow cytometry, Radioimmunoassay). 查看参考
  4. Wu Z, Zhang Z, Lei Z, Lei P. CD14: Biology and role in the pathogenesis of disease.. Cytokine Growth Factor Rev. 2019; 48:24-31. (Biology). 查看参考
查看所有文件 (4) 查看更少内容
752936 Rev. 2

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.