-
Reagents
- Flow Cytometry Reagents
-
蛋白质印迹试剂
- 免疫分析 试剂
-
Single-Cell Multiomics Reagents
- BD® AbSeq Assay
- BD Rhapsody™ 附件试剂盒
- BD® Single-Cell Multiplexing Kit
- BD Rhapsody™ TCR/BCR Next Multiomic Assays
- BD Rhapsody™ Targeted mRNA Kits
- BD Rhapsody™ Whole Transcriptome Analysis (WTA) Amplification Kit
- BD OMICS-Guard™ Sample Preservation Buffer
- BD Rhapsody™ ATAC-Seq Assays
- BD® OMICS-One Protein Panels
- BD OMICS-One™ WTA Next Assay
-
Functional Assays
-
显微成像试剂
-
Cell Preparation and Separation Reagents
Old Browser
Looks like you're visiting us from {countryName}.
Would you like to stay on the current location or be switched to your location?
BD Oncomark™ Anti-Human HLA-DR FITC/CD34 PE
Regulatory Status Legend
未经BD明确书面授权,严禁使用未经许可的任何商品。
描述
Anti–HLA-DR, clone L243, is derived from the hybridization of mouse NS-1/1-Ag4 myeloma cells with spleen cells from BALB/c mice immunized with the human lymphoblastoid B-cell line RPMI 8866. CD34 (Anti–HPCA-2), clone 8G12, is derived from hybridization of mouse Sp2/0-Ag14 cells with spleen cells of BALB/c mice immunized with the human cell line KG-1a. Anti–HLA-DR recognizes a human class II major histocompatibility complex (MHC) antigen. The antigen is a transmembrane glycoprotein composed of α and β subunits that have molecular weights of 36 and 27 kilodaltons (kd), respectively. The CD34 antigen is a single-chain transmembrane glycoprotein, Mr 105 to 120 kd. The antigen is associated with human hematopoietic progenitor cells and is a differentiation stage–specific leucocyte antigen. Anti–HPCA-1 and Anti–HPCA-2 (clone 8G12) recognize two distinct CD34 epitopes; at least three epitopes have been identified. Clone 8G12 recognizes the class 3 epitope.
准备和存储
Store vials at 2–8°C. Do not freeze reagents; protect them from prolonged exposure to light. Each reagent is stable for the period shown on the bottle label when stored as directed.
| 描述 | 数量/尺寸 | 零件号 | 克隆 | 同型对照 |
|---|---|---|---|---|
| Anti-HLA DR FITC | N/A | 50-7363 | L243 | IgG2a, κ |
Please refer to Support Documents for Quality Certificates
Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described
Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims. Comparisons are not made against non-BD technologies, unless otherwise noted.
For Research Use Only. Not for use in diagnostic or therapeutic procedures.
Although not required, these products are manufactured in accordance with Good Manufacturing Practices.