Skip to main content Skip to navigation
Anti-Human CD4 FITC/Leu™-8 (Leu-3a/Leu-8) PE

BD Simultest™ Anti-Human CD4 FITC/Leu™-8 (Leu-3a/Leu-8) PE

(RUO (GMP))
商品详情
Down Arrow Up Arrow


BD Simultest™
Human
Flow cytometry
RUO (GMP)
Phosphate buffered saline with gelatin and 0.1% sodium azide.


描述

The CD4 (Leu-3a) antigen, clone SK3, is derived from hybridization of NS-1 mouse myeloma cells with spleen cells from BALB/c mice immunized with human peripheral blood lymphocytes.

The Leu-8 antigen, clone SK11, is derived from hybridization of NS-1 mouse myeloma cells with spleen cells from BALB/C mice immunized with peripheral blood T lymphocytes.

The CD4 (Leu-3a) antigen, Mr 55 (kdalton) kDa, is present on T-helper/inducer lymphocytes and monocytes.

Leu-8 is a human leucocyte antigen, Mr 80 kDa.

准备和存储

Store vials at 2°C–8°C. Conjugated forms should not be frozen. Protect from exposure to light. Each reagent is stable until the expiration date shown on the bottle label when stored as directed.

349513 Rev. 1
组件
Down Arrow Up Arrow
描述 克隆 同型对照 EntrezGene ID
CD62L (L-Selectin) PE SK11 IgG2a, κ 6402
CD4 FITC SK3 IgG1, κ 920
349513 Rev. 1
报价单和参考
Down Arrow Up Arrow

研发参考 (19)

  1. Bernard A, Boumsell L, Hill C. Joint report of the first international workshop on human leucocyte differentiation antigens by the investigators of the participating laboratories: T2 protocol. In: Bernard A. A. Bernard .. et al., ed. Leucocyte typing : human leucocyte differentiation antigens detected by monoclonal antibodies : specification, classification, nomenclature = Typage leucocytaire : antigènes de différenciation leucocytaire humains révélés par les anticorps monoclonaux : "Rapports des études communes". Berlin New York: Springer-Verlag; 1984:25-60.
  2. Centers for Disease Control. Update: universal precautions for prevention of transmission of human immunodeficiency virus, hepatitis B virus, and other bloodborne pathogens in healthcare settings. MMWR. 1988; 37:377-388. (Biology).
  3. Clinical and Laboratory Standards Institute. 2005. (Biology).
  4. Dalgleish AG, Beverley PC, Clapham PR, Crawford DH, Greaves MF, Weiss RA. The CD4 (T4) antigen is an essential component of the receptor for the AIDS retrovirus.. Nature. 312(5996):763-7. (Biology). 查看参考
  5. Engleman EG, Benike CJ, Glickman E, Evans RL. Antibodies to membrane structures that distinguish suppressor/cytotoxic and helper T lymphocyte subpopulations block the mixed leukocyte reaction in man. J Exp Med. 1981; 154(1):193-198. (Biology). 查看参考
  6. Evans RL, Wall DW, Platsoucas CD, et al. Thymus-dependent membrane antigens in man: inhibition of cell-mediated lympholysis by monoclonal antibodies to TH2 antigen. Proc Natl Acad Sci U S A. 1981; 78(1):544-548. (Biology). 查看参考
  7. Gatenby PA, Kansas GS, Xian CY, Evans RL, Engleman EG. Dissection of immunoregulatory subpopulations of T lymphocytes within the helper and suppressor sublineages in man. J Immunol. 1982; 129(5):1997-2000. (Biology). 查看参考
  8. Kansas GS, Wood GS, Fishwild DM, Engleman EG. Functional characterization of human T lymphocyte subsets distinguished by monoclonal anti-leu-8. J Immunol. 1985; 134(5):2995-3002. (Biology). 查看参考
  9. Kotzin BL, Benike CJ, Engleman EG. Induction of immunoglobulin-secreting cells in the allogeneic mixed leukocyte reaction: regulation by helper and suppressor lymphocyte subsets in man. J Immunol. 1981; 127(9):931-935. (Biology). 查看参考
  10. Lanier LL, Engleman EG, Gatenby P, Babcock GF, Warner NL, Herzenberg LA. Correlation of functional properties of human lymphoid cell subsets and surface marker phenotypes using multiparameter analysis and flow cytometry. Immun Rev. 1983; 74:143. (Biology).
  11. Lanier LL, Loken MR. Human lymphocyte subpopulations identified by using three-color immunofluorescence and flow cytometry analysis: correlation of Leu-2, Leu-3, Leu-7, Leu-8, and Leu-11 cell surface antigen expression. J Immunol. 1984; 132:151. (Biology).
  12. Ledbetter JA, Evans RL, Lipinski M, Cunningham-Rundles C, Good RA, Herzenberg LA. Evolutionary conservation of surface molecules that distinguish T lymphocyte helper/inducer and cytotoxic/suppressor subpopulations in mouse and man. J Exp Med. 1981; 153(2):310-323. (Biology). 查看参考
  13. Lewis DE, Puck JM, Babcock GF, Rich RR. Disproportionate expansion of a minor T cell subset in patients with lymphadenopathy syndrome and acquired immunodeficiency syndrome.. J Infect Dis. 1985; 151(3):555-9. (Biology). 查看参考
  14. Marcos MR, Gaspar ML, de la Hera A, et al. Selective expansion of a CD3+CD4-CD8- subpopulation in clinical groups associated with human immunodeficiency virus infection. Scand J Immunol. 1987; 25:321. (Biology).
  15. Ohno T, Kanoh T, Suzuki T, et al. Comparative analysis of lymphocyte phenotypes between carriers of human immunodeficiency virus (HIV) and adult patients with primary immunodeficiency using two-color immunofluorescence flow cytometry.. Tohoku J Exp Med. 1988; 154(2):157-72. (Biology). 查看参考
  16. Reichert T, DeBruyere M, Deneys V, et al. Lymphocyte subset reference ranges in adult Caucasians. Clin Immunol Immunopathol. 1991; 60(2):190-208. (Biology). 查看参考
  17. Sattentau QJ, Dalgleish AG, Weiss RA, Beverley PC. Epitopes of the CD4 antigen and HIV infection. Science. 1986; 234(4780):1120-1123. (Biology). 查看参考
  18. Stites DP, Casavant CH, McHugh TM, et al. Flow cytometric analysis of lymphocyte phenotypes in AIDS using monoclonal antibodies and simultaneous dual immunofluorescence.. Clin Immunol Immunopathol. 1986; 38(2):161-77. (Biology). 查看参考
  19. Wood GS, Warner NL, Warnke RA. Anti–Leu-3/T4 antibodies react with cells of monocyte/macrophage and Langerhans lineage. J Immunol. 1983; 131(1):212-216. (Biology). 查看参考
查看所有文件 (19) 查看更少内容
349513 Rev. 1

Please refer to Support Documents for Quality Certificates

Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described

Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures. 

 

Although not required, these products are manufactured in accordance with Good Manufacturing Practices.