Skip to main content Skip to navigation
Oligo Mouse Anti-Mouse I-A[b]

BD™ AbSeq Oligo Mouse Anti-Mouse I-A[b]

Clone 25-9-17 (RUO)

940182
EA (1 Each)
25 Tests
Add Product To Quote견적 추가하기
제품 세부 정보
Down Arrow


BD™ AbSeq
Aβ[b]; H2-IA[b] beta chain; H-2 IA[b] beta chain
14961
2 µl
Mouse C3H, also known as C3H/He, C3H/Bi IgG2a, κ
Mouse (Tested in Development)
Single Cell 3' Sequencing (Qualified)
TGAGGTGTTATGTCGTTAGGGTCGTAGTGAAATTGC
AMM2078
Mouse C3H.SW Splenocytes
Aqueous buffered solution containing BSA and ≤0.09% sodium azide.
RUO
Mouse
Ms I-Ab Olgo AMM2078 25-9-17 25Tst


준비 및 보관

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography and conjugated to BD® AbSeq oligonucleotide under optimal conditions.

권장 분석 절차

Put all BD® AbSeq Reagents to be pooled into a Latch Rack for 500 µL Tubes (Thermo Fisher Scientific Cat. No. 4900). Arrange the tubes so that they can be easily uncapped and re-capped with an 8-Channel Screw Cap Tube Capper (Thermo Fisher Scientific Cat. No. 4105MAT) and the reagents aliquoted with a multi-channel pipette.

BD® AbSeq tubes should be centrifuged for ≥ 30 seconds at 400 × g to ensure removal of any content in the cap/tube threads prior to the first opening.

제품 고시

  1. This reagent has been pre-diluted for use at the recommended volume per test. Typical use is 2 µl for 1 × 10^6 cells in a 200-µl staining reaction.
  2. The production process underwent stringent testing and validation to assure that it generates a high-quality conjugate with consistent performance and specific binding activity. However, verification testing has not been performed on all conjugate lots.
  3. Please refer to bd.com/genomics-resources for technical protocols.
  4. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  5. Source of all serum proteins is from USDA inspected abattoirs located in the United States.
  6. Illumina is a trademark of Illumina, Inc.
  7. Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
  8. For U.S. patents that may apply, see bd.com/patents.

데이터 시트

관련 제품

Stain Buffer (FBS) RUO
사이즈 500 mL 카탈로그 No. 554656
sampleImage/
Single-Cell Analysis System RUO
사이즈 1 EACH 카탈로그 No. 633701
sampleImage/
Express Single-Cell Analysis System Package RUO
사이즈 1 EACH 카탈로그 No. 633707
sampleImage/
Targeted mRNA and AbSeq Training Kit 4 Pack RUO
사이즈 1 Each 카탈로그 No. 633772
sampleImage/
940182 Rev. 2
항체 세부 정보
Down Arrow
25-9-17

The 25-9-17 monoclonal antibody specifically recognizes the β chain of the I-A[b] MHC class II alloantigen.  It crossreacts with cells from mice of the H-2[d], H-2[p], and H-2[q] haplotypes.  Reactivity with other haplotypes (eg, a, f, g7, k, r, s) has not been observed.  The strain distribution of the antigen recognized by this reagent is similar or identical to that of anti-I-A[d] (Aβ[d]) mAb 34-5-3.

940182 Rev. 2
인용 및 참고 문헌
Down Arrow

개발 참고 자료 (4)

  1. Cohn LE, Glimcher LH, Waldmann RA, et al. Identification of functional regions on the I-Ab molecule by site-directed mutagenesis. Proc Natl Acad Sci U S A. 1986; 83(3):747-751. (Clone-specific). 참조 보기
  2. Ikegami H, Makino S, Harada M, Eisenbarth GS, Hattori M. The cataract Shionogi mouse, a sister strain of the non-obese diabetic mouse: similar class II but different class I gene products. Diabetologia. 1988; 31(4):254-258. (Clone-specific). 참조 보기
  3. Landias D, Beck BN, Buerstedde JM, et al.. The assignment of chain specificities for anti-Ia monoclonal antibodies using L cell transfectants. J Immunol. 1986; 137(9):3002-3005. (Clone-specific). 참조 보기
  4. Ozato K, Sachs DH. Monoclonal antibodies to mouse MHC antigens. III. Hybridoma antibodies reacting to antigens of the H-2b haplotype reveal genetic control of isotype expression. J Immunol. 1981; 126(1):317-321. (Immunogen: Cytotoxicity, Flow cytometry). 참조 보기