Skip to main content Skip to navigation
Mouse/Rat Soluble Protein Master Buffer Kit

BD™ Cytometric Bead Array (CBA) Mouse/Rat Soluble Protein Master Buffer Kit

(RUO)
제품 세부 정보
Down Arrow Up Arrow


BD™ Cytometric Bead Array (CBA)
Flow cytometry (Routinely Tested)
RUO
AB_2869126
Ms/Rat Solbl Ptein CBA Buf Kit 500Tst


558267 Rev. 1
구성품
Down Arrow Up Arrow
설명 수량 / 사이즈 부품 번호 EntrezGene ID
Wash Buffer 100 Tests (1 ea) 51-9003798 N/A
Capture Bead Diluent 100 Tests (1 ea) 51-9003804 N/A
PE* Positive Control Detector 100 Tests (1 ea) 51-9005065 N/A
PE Instrument Setup Bead F1 100 Tests (1 ea) 51-9005038 N/A
Instrument Setup Bead F1 100 Tests (1 ea) 51-9003851 N/A
Instrument Setup Bead F9 N/A 51-9003854 N/A
Instrument Setup Bead A1 N/A 51-9003855 N/A
Instrument Setup Bead A9 N/A 51-9003858 N/A
Assay Diluent 100 Tests (1 ea) 51-9003992 N/A
Detection Reagent Diluent 100 Tests (1 ea) 51-9003995 N/A
558267 Rev. 1
인용 및 참고 문헌
Down Arrow Up Arrow

개발 참고 자료 (11)

  1. Bishop JE, Davis KA. A flow cytometric immunoassay for β2-microglobulin in whole blood. J Immunol Methods. 1997; 210:79–87. (Biology).
  2. Camilla C, Defoort JP, Delaage M, et al. A new flow cytometry-based multi-assay system 1, Application to cytokine immunoassays. Cytometry Suppl. 1998; 8:132. (Biology).
  3. Carson R, Vignali D. Simultaneous quantitation of 15 cytokines using a multiplexed flow cytometric assay. J Immunol Methods. 1999; 227:41–52. (Biology).
  4. Chen, R, L Lowe, et al. Simultaneous quantification of six human cytokines in a single sample using microparticle-based flow cytometric technology. Clin Chem. 1999; 9:1693-1694. (Biology).
  5. Cook, EB, JL Stahl, et al. Simultaneous measurement of six cytokines in a single sample of human tears using microparticle-based flow cytometry: allergics vs non-allergics. J Immunol Methods. 2001; 254:109-118. (Biology).
  6. Dotti, G, B Salvodo, et al. Adenovector-induced expression of human-CD40-ligand (hCD40L) by multiple myeloma cells: A model for immunotherapy. Exp Hematol. 2001; 29:952-961. (Biology).
  7. Fulwyler M, McHugh TM. Flow microsphere immunoassay for the quantitative and simultaneous detection of multiple soluble analytes. Methods Cell Biol. 1994; 33:613-629. (Biology).
  8. Kricka LJ. Diamandis EP, Christopoulos TK, ed. Immunoassay. Academic Press; 1996:389-404.
  9. Lund-Johansen F, Davis K, Bishop J, de Waal Malefyt R. Flow cytometric analysis of immunoprecipitates: high-throughput analysis of protein phosphorylation and protein-protein interactions. Cytometry. 2000; 39(4):250-259. (Biology). 참조 보기
  10. Oliver KG, Kettman JR, Fulton RJ. Multiplexed analysis of human cytokines by use of the FlowMetrix system. Clin Chem. 1998; 44:2057-2060. (Biology).
  11. Stall, A, Q Sun, et al. A single tube flow cytometric multibead assay for isotyping mouse monoclonal antibodies, Abstract LB77. Experimental Biology Meeting. 1998. (Biology).
모두 보기 (11) 간단히 보기
558267 Rev. 1

Please refer to Support Documents for Quality Certificates

Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described

Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.