Skip to main content Skip to navigation
Mouse Inflammation Kit

BD™ Cytometric Bead Array (CBA) Mouse Inflammation Kit

(RUO)
제품 세부 정보
Down Arrow Up Arrow


BD™ Cytometric Bead Array (CBA)
Mouse (QC Testing)
Flow cytometry (Routinely Tested)
RUO
AB_2868960
Ms Inflammation CBA Kit


552364 Rev. 1
구성품
Down Arrow Up Arrow
설명 수량 / 사이즈 부품 번호 EntrezGene ID
E1 PE Positive Control Detector 1 Each (1 ea) 51-9005732 N/A
E2 FITC Positive Control Detector 1 Each (1 ea) 51-9005734 N/A
F Wash Buffer 1 Each (1 ea) 51-2431KC N/A
G Assay Diluent 1 Each (1 ea) 51-2432KC N/A
Mouse IL-6 Capture Beads N/A 51-9005811 15978
Mouse IL-10 Capture Beads N/A 51-9005813 15978
Mouse MCP-1 Capture Beads N/A 51-9005815 15978
Mouse IFN-γ Capture Beads 0.8 mL (1 ea) 51-9005807 N/A
Mouse TNF Capture Beads 0.8 mL (1 ea) 51-9005809 N/A
Mouse IL-12p70 Capture Beads N/A 51-9005817 15978
Mouse Inflammation PE* Detection Reagent (B) N/A 51-9000147 N/A
Mouse Inflammation Standards (C) 1 Vial(s) (2 ea) 51-9000148 N/A
D Cytometer Setup Beads 1 Each (1 ea) 51-9005731 N/A
552364 Rev. 1
인용 및 참고 문헌
Down Arrow Up Arrow

개발 참고 자료 (13)

  1. Bishop JE, Davis KA. A flow cytometric immunoassay for β2-microglobulin in whole blood. J Immunol Methods. 1997; 210:79–87. (Biology).
  2. Camilla C, Defoort JP, Delaage M, et al. A new flow cytometry-based multi-assay system 1, Application to cytokine immunoassays. Cytometry Suppl. 1998; 8:132. (Biology).
  3. Carson R, Vignali D. Simultaneous quantitation of 15 cytokines using a multiplexed flow cytometric assay. J Immunol Methods. 1999; 227:41–52. (Biology).
  4. Chen, R, L Lowe, et al. Simultaneous quantification of six human cytokines in a single sample using microparticle-based flow cytometric technology. Clin Chem. 1999; 9:1693-1694. (Biology).
  5. Collins DP, Luebering BJ, Shaut DM. T-lymphocyte functionality assessed by analysis of cytokine receptor expression, intracellular cytokine expression, and femtomolar detection of cytokine secretion by quantitative flow cytometry. Cytometry. 1998; 33:249-255. (Biology).
  6. Cook, EB, JL Stahl, et al. Simultaneous measurement of six cytokines in a single sample of human tears using microparticle-based flow cytometry: allergics vs non-allergics. J Immunol Methods. 2001; 254:109-118. (Biology).
  7. Dotti, G, B Salvodo, et al. Adenovector-induced expression of human-CD40-ligand (hCD40L) by multiple myeloma cells: A model for immunotherapy. Exp Hematol. 2001; 29:952-961. (Biology).
  8. Fulton RJ, McDade RL, Smith PL, Kienker LJ, Kettman JR Jr. Advanced multiplexed analysis with the FlowMetrix system. Clin Chem. 1997; 43:1749-1756. (Biology).
  9. Fulwyler M, McHugh TM. Flow microsphere immunoassay for the quantitative and simultaneous detection of multiple soluble analytes. Methods Cell Biol. 1994; 33:613-629. (Biology).
  10. Kricka LJ. Diamandis EP, Christopoulos TK, ed. Immunoassay. Academic Press; 1996:389-404.
  11. Lund-Johansen F, Davis K, Bishop J, de Waal Malefyt R. Flow cytometric analysis of immunoprecipitates: high-throughput analysis of protein phosphorylation and protein-protein interactions. Cytometry. 2000; 39(4):250-259. (Biology). 참조 보기
  12. Oliver KG, Kettman JR, Fulton RJ. Multiplexed analysis of human cytokines by use of the FlowMetrix system. Clin Chem. 1998; 44:2057-2060. (Biology).
  13. Stall, A, Q Sun, et al. A single tube flow cytometric multibead assay for isotyping mouse monoclonal antibodies, Abstract LB77. Experimental Biology Meeting. 1998. (Biology).
모두 보기 (13) 간단히 보기
552364 Rev. 1

Please refer to Support Documents for Quality Certificates

Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described

Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.