Skip to main content Skip to navigation
Immune surveillance and Immune Deficiencies

The immune system provides surveillance and protection from pathogenic invaders and prevents detrimental responses against the self that could lead to autoimmunity. Alterations or dysregulations of components of the immune system, be it in the immune cells or their signaling pathways, can cause either low- (immune deficiency) or hyper-activity (autoimmunity) of the immune system.

 

Complete blood count (CBC) test, which is often part of routine/annual checkup, does not provide granular information at the lymphocyte level. Flow cytometry is widely used to gain deeper insights into immune cell populations through immunophenotyping for disease-specific assessments.

 
Average frequency of Leukocytes and lymphocyte subpopulations in a complete blood count
performance1

We offer a range of reagents, such as BD Multitestreagents with optional BD Trucount Tubes, that are intended for use in the immunological assessment of normal individuals and patients having, or suspected of having, immune deficiency. Together with instrumentation and software, they provide a complete IVD solution for immunological assessment.

IVD Immune Assessment Portfolio
Immune Deficiencies

Lymphocyte Subset Testing- Available Reagent Combinations

All BD Multitest™ Reagents integrate seamlessly with our BD FACSLyric™ Flow Cytometer and FACSDuet™ Sample Preparation System that streamlines your lab workflow through flexibility and automation, boosting efficiency and productivity. BD FACSuite™ Multitest assay modules provide predefined instrument settings and premade templates with gating algorithms for acquisition and analysis that simplifies the overall workflow.

The FACSLyric™ Flow Cytometer  with  FACSDuet™ Sample Preparation System provides a complete IVD walkaway sample-to-answer solution, eliminating hands-on time for preparation. The system is designed to complement and physically integrate with the BD FACSLyric™ Flow Cytometer to drive productivity and accuracy in your results through its automation protocol, minimizing manual intervention. The BD FACSLyric™ Flow Cytometer comes with the BD FACSuite™ and BD FACSuite™ Clinical Applications for sample acquisition and data analysis. Both applications include password protection, audit trail, electronic signatures and IQ/OQ procedures, assisting in supporting 21 CFR Part 11 compliance and electronic record integrity.

 

SKUProductTotal T CellsT Helper CellsT Cytotoxic CellsNK CellsB CellsAbsolute Counts
662967BD Multitest™ 6-Color
TBNK Reagents
XXXXX 
662995BD Multitest™ 6-Color
TBNK Reagents with
BD Trucount™ Tubes
XXXXXX
662965BD Multitest™ IMK KitXXXXX 
662966BD Multitest™ IMK Kit
with BD Trucount™ Tubes
XXXXXX
340499BD Multitest™
CD3/CD8/CD45/CD4
XXX   
340500BD Multitest™ CD3/CD16+
/CD56/CD45/CD19
X  XX 
340334BD Trucount™ Troucount
Absolute Counting Tubes IVD
     X

 

Human immunodeficiency virus (HIV) infection results in the  depletion of  CD4+ T-cell population through various mechanisms.1 Viral load monitoring and CD4 T-cell count are routinely used for HIV monitoring. CD4 T-cell count measurements are critical for gaining insights into HIV disease progression.1

Flow cytometry is a standard technique used for determining CD4 counts as it provides accuracy, precision and reproducibility. Both percentage CD4+ T-lymphocytes among lymphocytes and absolute lymphocyte counts can be determined using flow cytometry. 2

We offer various clinical CD4 testing solutions, including a fully automated clinical  flow cytometer, sample preparation reagents and software.

The FACSLyric™ Flow Cytometer streamlines your lab workflow through flexibility and automation, enabling efficiency and productivity.

The BD FACSuite™ Clinical Application  with predefined templates for 4-color BD Multitest™ Reagent and 6-color TBNK analysis, provides reproducible and consistent results.

It works with the FACSLyric™ Flow Cytometer for acquisition and analysis, supporting many functions and options relevant to U.S. FDA 21 CFR Part 11 compliance, including password protection, audit trail, electronic signatures and IQ/OQ procedures.

Universal setup is an automated system that establishes and maintains instrument MFI target values on a single instrument using the BD FACSuite™ Clinical Application, BD® CS&T Beads and BD® FC Beads, allowing for reproducible and consistent results within and between BD FACSLyric™ instruments over time. These settings can be easily transferred from instrument-to-instrument via the BD FACSuite™ Clinical Application assay export and transfer feature automating standardization and enabling collaboration across sites.

 

Automation Streamlines your daily workflow, improving efficiency and productivity

 


The BD FACSLyric™ Flow Cytometer Integrated with the BD FACSDuet™ Sample Preparation System provides a complete walkaway sample-to-answer solution. The system is designed to complement and physically integrate with the BD FACSLyric™ Flow Cytometer and drives productivity and accuracy in your results through its automation protocol, minimizing manual intervention. It supports ISO 15189-accredited labs with compliance with complete workflow traceability. BD Multitest™ Reagents, when used with BD Trucount™ Tubes, provide absolute counting capability. Each reagent includes a cocktail of multiple fluorescently labeled monoclonal antibodies, premixed at the appropriate titer to ensure quality staining.

Lymphocyte Subset Testing- Available Reagent Combinations

All BD Multitest™ Reagents integrate seamlessly with our BD FACSLyric™ Flow Cytometer and FACSDuet™ Sample Preparation System that streamlines your lab workflow through flexibility and automation, boosting efficiency and productivity. BD FACSuite™ Multitest assay modules provide predefined instrument settings and premade templates with gating algorithms for acquisition and analysis that simplifies the overall workflow.

The FACSLyric™ Flow Cytometer  with  FACSDuet™ Sample Preparation System provides a complete IVD walkaway sample-to-answer solution, eliminating hands-on time for preparation. The system is designed to complement and physically integrate with the BD FACSLyric™ Flow Cytometer to drive productivity and accuracy in your results through its automation protocol, minimizing manual intervention. The BD FACSLyric™ Flow Cytometer comes with the BD FACSuite™ and BD FACSuite™ Clinical Applications for sample acquisition and data analysis. Both applications include password protection, audit trail, electronic signatures and IQ/OQ procedures, assisting in supporting 21 CFR Part 11 compliance and electronic record integrity.

 

SKUProductTotal T CellsT Helper CellsT Cytotoxic CellsNK CellsB CellsAbsolute Counts
662967BD Multitest™ 6-Color
TBNK Reagents
XXXXX 
662995BD Multitest™ 6-Color
TBNK Reagents with
BD Trucount™ Tubes
XXXXXX
662965BD Multitest™ IMK KitXXXXX 
662966BD Multitest™ IMK Kit
with BD Trucount™ Tubes
XXXXXX
340499BD Multitest™
CD3/CD8/CD45/CD4
XXX   
340500BD Multitest™ CD3/CD16+
/CD56/CD45/CD19
X  XX 
340334BD Trucount™ Troucount
Absolute Counting Tubes IVD
     X

 

Human immunodeficiency virus (HIV) infection results in the  depletion of  CD4+ T-cell population through various mechanisms.1 Viral load monitoring and CD4 T-cell count are routinely used for HIV monitoring. CD4 T-cell count measurements are critical for gaining insights into HIV disease progression.1

Flow cytometry is a standard technique used for determining CD4 counts as it provides accuracy, precision and reproducibility. Both percentage CD4+ T-lymphocytes among lymphocytes and absolute lymphocyte counts can be determined using flow cytometry. 2

We offer various clinical CD4 testing solutions, including a fully automated clinical  flow cytometer, sample preparation reagents and software.

The FACSLyric™ Flow Cytometer streamlines your lab workflow through flexibility and automation, enabling efficiency and productivity.

The BD FACSuite™ Clinical Application  with predefined templates for 4-color BD Multitest™ Reagent and 6-color TBNK analysis, provides reproducible and consistent results.

It works with the FACSLyric™ Flow Cytometer for acquisition and analysis, supporting many functions and options relevant to U.S. FDA 21 CFR Part 11 compliance, including password protection, audit trail, electronic signatures and IQ/OQ procedures.

Universal setup is an automated system that establishes and maintains instrument MFI target values on a single instrument using the BD FACSuite™ Clinical Application, BD® CS&T Beads and BD® FC Beads, allowing for reproducible and consistent results within and between BD FACSLyric™ instruments over time. These settings can be easily transferred from instrument-to-instrument via the BD FACSuite™ Clinical Application assay export and transfer feature automating standardization and enabling collaboration across sites.

 

Automation Streamlines your daily workflow, improving efficiency and productivity

 


The BD FACSLyric™ Flow Cytometer Integrated with the BD FACSDuet™ Sample Preparation System provides a complete walkaway sample-to-answer solution. The system is designed to complement and physically integrate with the BD FACSLyric™ Flow Cytometer and drives productivity and accuracy in your results through its automation protocol, minimizing manual intervention. It supports ISO 15189-accredited labs with compliance with complete workflow traceability. BD Multitest™ Reagents, when used with BD Trucount™ Tubes, provide absolute counting capability. Each reagent includes a cocktail of multiple fluorescently labeled monoclonal antibodies, premixed at the appropriate titer to ensure quality staining.

Performance

Why BD?

  • Portfolio of BD Multitest Reagents to choose from to suit your clinical needs
  • Single platform absolute counts with BD Trucount Tubes, which require no additional instrument and/or pipetting steps, for accurate, precise and reproducible results
  • Together with the BD FACSLyric Flow Cytometer and BD FACSuite Clinical Application, the BD FACS™  Universal Loader option and the BD FACSDuet™ Sample Preparation System, the BD Multitest reagents & IMK kit provide a fully automated, standardized and efficient workflow for lymphocyte enumeration to best suit your routine immunophenotyping needs.
  • A streamlined methodology for immunological assessment using the BD FACSLyric™ Flow Cytometry System
performance1

References

  1. Cowley S. The biology of HIV infection. Lepr Rev. (2001);72(2):212-220. doi: 10.5935/0305-7518.20010028

  2. Flynn J and Gorry P. Flow Cytometry Analysis to Identify Human CD4+ T Cell Subsets. Methods Mol Biol. (2019); 2048:15-25. doi: 10.1007/978-1-4939-9728-2_2.