Skip to main content Skip to navigation


Cross-Reactive Antibodies for Human and Non Human Primate Research

Use a single flow cytometry panel across human and non-human primate (NHP) samples with cross-reactive antibody clones

 

Identify antibody clones that deliver consistent performance across human and NHP samples, enabling the use of a common flow cytometry panel across species. This resource is especially valuable for NHP toxicology, biodistribution, mechanistic, and translational studies, helping improve data comparability and continuity from preclinical research through clinical development.

 

We offer both ready-to-order NHP antibodies and custom solutions, including alternative fluorophore conjugations, higher‑concentration formats, and tailored formulations to help you build flow cytometry panels for both human and non-human primate samples.

 

If your research spans both human and NHP studies, the cross-reactivity chart below can help you identify antibody clones that recognize targets across species, enabling greater panel continuity and data comparability. The information is based on a combination of in-house testing and data from reputable external databases.

 

Please note that Waters Biosciences has not independently verified every cross-reactivity listed below.

 

SpecificityClone NameHumanBaboonCynoRhesusChimpanzeeAfrican Green Monkey
CD2RPA-2.10++++ R
CD3SP34-2++++  
CD4L200++++  
CD4M-T477++++  
CD4RPA-T4++++  
CD7M-T701++++  
CD8OKT8++++  
CD8RPA-T8+++++ 
CD8SK1+++++ 
CD8b2ST8.5H7+ ++  
CD10HI10a++++ R
CD11aHI111++++R 
CD11bICRF44++++ R
CD11c3.9+RR++ 
CD13WM15R    R
CD14M5E2+++++R
CD14MφP9+++++ 
CD163G8++++ R
CD186.7+ ++  
CD19HIB19+  R  
CD202H7++++ R
CD20L27++++  
CD21B-ly4++++  
CD252A3+ +++ 
CD25BC96+RRR+ 
CD25M-A251+++++ 
CD27O323RRRR R
CD27L128++++  
CD27M-T271++++  
CD28CD28.2++++ R
CD28L293++++  
CD29MAR4++++  
CD31WM59++++ R
CD32 (FcγRII)FLI8.26++++  
CD34563+ +++ 
CD34581+   + 
CD35E11RRRR R
CD39A1RRRR R
CD405C3++++  
CD40HB14+RRR R
CD41aHIP8++++ R
CD44v62F10+  +  
CD45RA5H9++++  
CD49d9F10++++ R
CD49fGoH3RRRR R
CD5123C6R R  R
CD56R19-760++++  
CD57B159++++  
CD58MY31++++  
CD59NCAM16.2++++  
CD59p282 (H19)++++  
CD61VI-PL2++++ R
CD62LSK11++++  
CD62LAC1.2++++  
CD62LAK-4+ ++  
CD63H5C6++++ R
CD6410.1RRRR R
CD69FN50++++ R
CD73AD2RR   R
CD74LN2RRRR R
CD79bCB3-1RRRR R
CD81JS-81++++  
CD811D6+  +  
CD83HB15e++++ R
CD862331 (FUN-1)++++  
CD86IT2.2+RRR R
CD89A59RRRR R
CD905E10++++  
CD95 (Fas)DX2+++++R
CD97VIM3bR  R  
CD100A8RRRR R
CD107aH4A3RRRR R
CD119GIR-208RRRR R
CD152BNI3++++  
CD154 (CD40 Ligand)24-31+ RR  
CD154 (CD40 Ligand)TRAP1++++  
CD183 (CXCR3)1C6/CXCR3++++  
CD184 (CXCR4)12G5++++ R
CD195 (CCR5)3A9+ ++  
CD196 (CCR6)11A9++++  
CD161HP-3G10RRRR R
CD162KPL-1RRRR R
CD163GHI/61R RR R
CD1663A6RRRR R
CD243 (ABCB1)UIC2RR   R
CD274 (PD-L1)29E.2A3RRRR R
CD278 (ICOS)C398.4A+RR+ R
CD317Y129++++  
CD3703A4/Clec9A+ +   
Annexin VAnnexin V+ +++ 
HLA-ABCW6/32RRRR R
HLA-ABCG46-2.6++++  
HLA-DRG46-6++++  
HLA-DRL243++++ R
HLA-DRTU36++++  
HLA-DR, DP, DQTu39++++  
HU FOXP3259D/C7++++  
IFN-γ4S.B3++++  
IFN-γB27++++  
IL-2MQ1-17H12++++  
IL-48D4-8+ ++  
IL-4MP4-25D2+  +  
IL-5TRFK4++++  
IL-5TRFK5++++  
IL-6MQ2-6A3+ ++  
Integrin β7FIB504RRRR R
Ki-67B56++++  
LOX-115C4++++  
MCP-15D3-F7+ ++  
MIP-1α11A3+ ++  
RbG3-245++    
Stat34/P-STAT3+   + 
Stat5 (pY694)47/Stat5(pY694)++ +  
TCR-gamma/deltaB1RRRR R
TNFMAb1++++  
TNFMAb11++++  
TRA-1-60 AntigenTRA-1-60+  +  
TRA-1-81 AntigenTRA-1-81+  R  

 

+ = positive   - = negative   R = reported (see reference below)   blank = not tested/reported

Reference: Cell type-specific monoclonal antibody cross-reactivity screening in non-human primates and development of comparative immunophenotyping panels for CyTOF. Zachary B Bjornson-Hooper, Gabriela K Fragiadakis, Matthew H Spitzer, Deepthi Madhireddy, Kevin Hu, Kelly Lundsten, Garry P Nolan

 

When using cross‑reactive antibodies, you may observe differences in signal intensity or antigen density due to natural variation in expression profiles between species. To ensure accurate and reproducible results, we recommend a quick titration to determine the best staining concentration for each cell type and maximize resolution and specificity.

Representative flow cytometry data illustrating staining on human and rhesus whole blood for selected clones to highlight assay performance and species‑specific differences.



CD3 SP34-2
`

Rhesus

Multiparameter flow cytometric analysis of CD3 expression on Rhesus monkey peripheral blood leukocyte populations. Rhesus whole blood was stained with either BD Horizon™ RY743 Mouse IgG1, κ Isotype Control (Cat. No. 572209; Left Plot) or BD Horizon™ RY743 Mouse Anti-Human CD3 antibody (Cat. No. 572740/572800; Right Plot). The erythrocytes were lysed with BD FACS™ Lysing Solution (Cat. No. 349202). Flow cytometry and data analysis were performed using a BD FACSymphony™ A5 SE Cell Analyzer System and FlowJo™ Software.  

`

Human

Multiparameter flow cytometric analysis of CD3 expression on Human peripheral blood leukocyte populations. Human whole blood was stained with either BD Horizon™ RY743 Mouse IgG1, κ Isotype Control (Cat. No. 572209; Left Plot) or BD Horizon™ RY743 Mouse Anti-Human CD3 antibody (Cat. No. 572740/572800; Right Plot) at the same dose as the Rhesus leukocytes. The erythrocytes were lysed with BD FACS Lysing Solution (Cat. No. 349202). Flow cytometry and data analysis were performed using a BD FACSymphony™ A5 SE Cell Analyzer System and FlowJo™ Software.   

CD4 L200

Rhesus

Multiparameter flow cytometric analysis of CD4 expression on Rhesus macaque peripheral blood leukocyte populations. Rhesus macaque whole blood was stained with either BD Horizon™ RY775 Mouse IgG1, κ Isotype Control (Cat. No. 571408; Left Plot) or BD Horizon™ RY775 Mouse Anti-Human CD4 antibody (Cat. No. 571661/571739; Right Plot). The erythrocytes were lysed with BD FACS™ Lysing Solution (Cat. No. 349202). Flow cytometry and data analysis were performed using a BD LSRFortessa™ X-20 Cell Analyzer System and FlowJo™ Software.

`

Human

Multiparameter flow cytometric analysis of CD4 expression on Human peripheral blood leukocyte populations. Human whole blood was stained with either BD Horizon™ RY775 Mouse IgG1, κ Isotype Control (Cat. No. 571408; Left Plot) or BD Horizon™ RY775 Mouse Anti-Human CD4 antibody (Cat. No. 571661/571739; Right Plot). The erythrocytes were lysed with BD FACS™ Lysing Solution (Cat. No. 349202). Flow cytometry and data analysis were performed using a BD LSRFortessa™ X-20 Cell Analyzer System and FlowJo™ Software.

   

   

For Research Use Only. Not for use in diagnostic or therapeutic procedures. Not for Resale.