Skip to main content Skip to navigation
BD Horizon RealBlue™ 780 Reagents
A Bright, Clean Dye

BD Horizon RealBlue™ 780 (RB780) Reagents leverage an innovative laser-specific fluorochrome, excited primarily by the 488-nm blue laser to offer:

 

  • Minimal cross-laser excitation off the 561-nm yellow-green laser
  • A bright fluorochrome to support the detection of low-expression surface and intracellular markers
  • Reduced monocyte background compared to PE-Cy7

RB780 Reagents Can Be Used with PE-Cy7 on Appropriately Configured Conventional and Spectral Flow Cytometers

RB780 specifications

 

FormatEx MaxEm MaxSpectralConventionalRelative BrightnessSpillover* (1 = low, 4 = high)Alternative To
RB780488 nm780 nm 1PE-Cy7,
PerCP/Fire™ 780,
BB790-P
 
*Value may vary based on instrument configuration and settings. Spillover ranking is based on cross-laser excitation on five-laser spectral instruments and does not take into account spillover into adjacent detectors.
 

View Products

Performance

BD Horizon RealBlue 780 Reagents Provide Minimal Cross-laser Excitation Off the 561-nm Yellow-Green Laser and Reduced Background Compared to PE-Cy7

 
RB780 has minimal cross-laser excitation
RB780 Minimum Cross Laser Excitation

Normalized emission profiles of RB780 and PE-Cy7 fluorochromes. Human CD4 SK3 antibody acquired on a BD FACSDiscover S8 Cell Sorter.

Compared to PE-Cy7, RB780 shows lower spillover spread into detectors on the yellow-green laser
RB780 Lower Spillover

Human whole blood was stained with BD Horizon RB780 Human CD4 (SK3) Reagent, acquired and compensated on a BD FACSymphony A5 SE Cell Analyzer. The biexponential scaling was set for PE-Cy7 and applied to RB780 to highlight changes in spread into selected channels.

 

BD Horizon™ RB780 Reagents offer reduced background compared to PE-Cy7
RB780 reduced background compared to PE0Cy7

Human whole blood was stained with PE-Cy7 or BD Horizon™ RB780 conjugated to human CD3 (UCHT1) Reagent, CD4 (SK3), human CD8 (RPA-T8), or human CD19 (SJ25C1), followed by lysis with BD FACS Lysing Solution. All specificities are analyzed with the B810 detector on a BD FACSymphony A5 SE Cell Analyzer.

View Products

 

Applications

Multicolor Flow Cytometry

BD Horizon™ RB780 Reagents Resolve Well in a 12-color T Cell Inhibitory Panel Acquired on the BD FACSLyric™ Flow Cytometry System

 

Gating scheme of T cell subsets
RB780 Resolution- n-BD FACSLyric 12-Color Panel

Healthy PBMC were stained with a 12-color inhibitory T cell panel and acquired on the BD FACSLyric Flow Cytometry System. Labels on top of each plot show the parental gate from which plots are derived; numbers in each quadrant represent the frequency of cell population; T cell subsets are identified as N, naïve; CM, central memory; EM, effector memory; EMRA, effector memory RA+; and SCM, stem cell like memory.

RB780 Reagents and PE-Cy7 Can Be Used Together in Spectral Flow Cytometry

 

RB780 reagents and PE-Cy7 are used together in a multicolor panel to identify rare cell populations

RB780-PE-Cy7-Multicolor-Flow-Usage

BD Horizon RB780 Reagents and PE-Cy7 can be used together in a multicolor panel to identify rare cell populations. CD123 BD Horizon RB780 Reagent and CD303 PE-Cy7 co-expresses on a sub-population of human plasmacytoid dendritic cells (pDC). Flow plots show clear distinction of the pDC population marked as CD123+ CD303+ cells derived from lineage negative CD14-CD16-, HLA-DR+ CD11c- cell populations in healthy PBMC samples. Samples were stained with the panel reagents along with Human BD Fc Block Reagent and analyzed on a BD FACSymphony A5 SE Flow Cytometer. FlowJov10.8 Software was used for spectral unmixing and analysis.

 

View Products

Buffer Compatibility

BD Horizon RealBlue RB780 Reagents Are Compatible with a Broad Range of Fixation and Permeabilization Systems

 

BuffersResults
BD FACS™ Lysing Solution and BD Pharm Lyse™ Lysing BufferCompatible
CellBlox™ Blocking BufferCompatible
BD Cytofix™ Fixation BufferStable at least 24 hours
1% PFAStable at least 24 hours
BD Cytofix/Cytoperm™ Fixation and Permeabilization SolutionCompatible with antibody staining before and after fixation
BD FACS™ Permeabilizing Solution 2Compatible with antibody staining before and after fixation
BD Phosflow™ Perm Buffer IIICompatible with antibody staining before and after fixation
EDTA and HeparinCompatible
BD Horizon™ Brilliant Stain Buffer (BSB)Compatible
 

   

   

BD flow cytometers are Class 1 Laser Products. For Research Use Only. Not for use in diagnostic or therapeutic procedures.

The BD FACSLyric™ Flow Cytometer is for Research Use Only with BD FACSuite™ Application for up to 12 colors. Not for use in diagnostic or therapeutic procedures.

CF is a trademark of Biotium, Inc. Cy is a trademark of Global Life Sciences Solutions Germany GmbH or an affiliate doing business as Cytiva. CellBlox is a trademark of Thermo Fisher Scientific.