Skip to main content Skip to navigation
PE Goat Anti-Human Ig κ Light Chain

BD Pharmingen™ PE Goat Anti-Human Ig κ Light Chain

Clone Polyclonal

(RUO)
PE Goat Anti-Human Ig κ Light Chain
Flow cytometric analysis of Ig κ Light Chain expression on human peripheral blood lymphocytes. Peripheral blood mononuclear cells (PBMC) were incubated in complete tissue culture medium overnight in order to minimize the amount of endogenous cytophilic antibody remaining bound to the leucocytes. The cells were harvested and stained with BD Pharmingen™ APC Mouse Anti-Human CD19 antibody (Cat. No. 555415 or 561742) and either PE Goat F(ab')2 IgG Isotype Control (Cat. No. 567016; Left Panel) or PE Goat Anti-Human Ig κ Light Chain antibody (Cat. No. 567015; Right Panel). Bivariate pseudocolor density plots showing the correlated expression of Ig κ Light Chain, including residual cytophilic antibodies, (or Ig Isotype control staining) versus CD19 were derived from events with the forward and side light-scatter characteristics of viable lymphocytes. Flow cytometry and data analysis were performed using a BD™ FACSCelesta Flow Cytometer System and FloJo™ software.
Flow cytometric analysis of Ig κ Light Chain expression on human peripheral blood lymphocytes. Peripheral blood mononuclear cells (PBMC) were incubated in complete tissue culture medium overnight in order to minimize the amount of endogenous cytophilic antibody remaining bound to the leucocytes. The cells were harvested and stained with BD Pharmingen™ APC Mouse Anti-Human CD19 antibody (Cat. No. 555415 or 561742) and either PE Goat F(ab')2 IgG Isotype Control (Cat. No. 567016; Left Panel) or PE Goat Anti-Human Ig κ Light Chain antibody (Cat. No. 567015; Right Panel). Bivariate pseudocolor density plots showing the correlated expression of Ig κ Light Chain, including residual cytophilic antibodies, (or Ig Isotype control staining) versus CD19 were derived from events with the forward and side light-scatter characteristics of viable lymphocytes. Flow cytometry and data analysis were performed using a BD™ FACSCelesta Flow Cytometer System and FloJo™ software.
제품 세부 정보
Down Arrow Up Arrow


BD Pharmingen™
Hu Kpa Lgt Chn PE POLY/HIGK 100Tst
Human (QC Testing)
Goat IgG, F(ab')2
Human Ig κ Light Chains
Flow cytometry (Routinely Tested)
5 µl
AB_2870005
Aqueous buffered solution containing BSA and ≤0.09% sodium azide.
RUO


준비 및 보관

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The antibody was conjugated with R-PE under optimum conditions, and unconjugated antibody and free PE were removed. The polyclonal antibody was purified from antiserum by negative adsorption and affinity chromatography.

권장 분석 절차

Some B lymphocytes and non-B leucocytes express Fc Receptors that can selectively bind various immunoglobulins from the plasma. As a result, these "cytophilic antibodies" can be detected on the cell surface using anti-Ig antibodies. Overnight incubation of peripheral blood mononuclear cells (PBMC) at 37ºC in complete tissue culture medium reportedly reduces the amount of these cytophilic antibodies observed on the PBMC. Costaining the PBMC with anti-CD20 or anti-CD19 and gating on the B lymphocytes eliminates detection of the cytophilic antibodies on the non-B cell populations, but a small proportion of the gated B lymphocytes may still express cytophilic antibodies.

BD™ CompBeads can be used as surrogates to assess fluorescence spillover (Compensation).  When fluorochrome conjugated antibodies are bound to CompBeads, they have spectral properties very similar to cells.   However, for some fluorochromes there can be small differences in spectral emissions compared to cells, resulting in spillover values that differ when compared to biological controls.  It is strongly recommended that when using a reagent for the first time, users compare the spillover on cell and CompBead to ensure that BD Comp beads are appropriate for your specific cellular application.

제품 고시

  1. This reagent has been pre-diluted for use at the recommended Volume per Test. We typically use 1 × 10^6 cells in a 100-µl experimental sample (a test).
  2. An isotype control should be used at the same concentration as the antibody of interest.
  3. Source of all serum proteins is from USDA inspected abattoirs located in the United States.
  4. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  5. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  6. Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
  7. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
567014 Rev. 1
항체 세부 정보
Down Arrow Up Arrow
poly/hIgK

The Goat Anti-Human Ig κ Light Chain polyclonal antibody specifically recognizes human immunoglobulin kappa light chains (Igκ). Immunoglobulins are expressed on the surface of B lymphocytes and plasma cells, and they also circulate in the serum. The two light chains in an immunoglobulin are of the same type, either Igκ or lambda (Igλ). Immunoglobulins bearing Igκ are expressed on a majority of normal B lymphocytes and on neoplastic cells of some leukemias, lymphomas, and plasmacytomas. In ELISA, the Goat Anti-Human Ig κ Light Chain polyclonal antibody binds to human immunoglobulins bearing Igκ and not to immunoglobulins bearing Igλ. Cross-reactivity to Igκ of other species is possible.

The polyclonal antibody is derived from pooled antisera obtained from hyperimmunized goats, is purified by affinity chromatography on human Igκ, and is cross-adsorbed against human Igλ. It is provided as F(ab')2 fragments.

567014 Rev. 1
형광 세부 정보
Down Arrow Up Arrow
PE
R-Phycoerythrin (PE), is part of the BD family of Phycobiliprotein dyes. This fluorochrome is a multimeric fluorescent phycobiliprotein with excitation maximum (Ex Max) of 496 nm and 566 nm and an emission maximum (Em Max) at 576 nm. PE is designed to be excited by the Blue (488 nm), Green (532 nm) and Yellow-Green (561 nm) lasers and detected using an optical filter centered near 575 nm (e.g., a 575/26-nm bandpass filter). As PE is excited by multiple lasers, this can result in cross-laser excitation and fluorescence spillover on instruments with various combinations of Blue, Green, and Yellow-Green lasers. Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
altImg
PE
Yellow-Green 488 nm, 532 nm, 561 nm
496 nm, 566 nm
576 nm
567014 Rev.1
인용 및 참고 문헌
Down Arrow Up Arrow

개발 참고 자료 (4)

  1. Fukushima PI, Nguyen PK, O'Grady P, Stetler-Stevenson M. Flow cytometric analysis of kappa and lambda light chain expression in evaluation of specimens for B-cell neoplasia.. Cytometry. 1996; 26(4):243-52. (Methodology: Flow cytometry, Immunofluorescence). 참조 보기
  2. Kubagawa H, Gathings WE, Levitt D, Kearney JF, Cooper MD. Immunoglobulin isotype expression of normal pre-B cells as determined by immunofluorescence.. J Clin Immunol. 1982; 2(4):264-9. (Biology: Immunofluorescence). 참조 보기
  3. Picker LJ, Weiss LM, Medeiros LJ, Wood GS, Warnke RA. Immunophenotypic criteria for the diagnosis of non-Hodgkin's lymphoma.. Am J Pathol. 1987; 128(1):181-201. (Biology: Immunohistochemistry). 참조 보기
  4. Smith BR, Weinberg DS, Robert NJ, et al. Circulating monoclonal B lymphocytes in non-Hodgkin's lymphoma.. N Engl J Med. 1984; 311(23):1476-81. (Biology: Flow cytometry). 참조 보기
모두 보기 (4) 간단히 보기
567014 Rev. 1

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.