Training
- Flow Cytometry Basic Training
-
Product-Based Training
- BD Accuri™ C6 Plus Cell Analyzer
- BD FACSAria™ Cell Sorter Cell Sorter
- BD FACSCanto™ Cell Analyzer
- BD FACSDiscover™ A8 Cell Analyzer
- BD FACSDiscover™ S8 Cell Sorter
- BD FACSDuet™ Sample Preparation System
- BD FACSLyric™ Cell Analyzer
- BD FACSMelody™ Cell Sorter
- BD FACSymphony™ Cell Analyzer
- BD LSRFortessa™ Cell Analyzer
- Advanced Training
-
- BD Accuri™ C6 Plus Cell Analyzer
- BD FACSAria™ Cell Sorter Cell Sorter
- BD FACSCanto™ Cell Analyzer
- BD FACSDiscover™ A8 Cell Analyzer
- BD FACSDiscover™ S8 Cell Sorter
- BD FACSDuet™ Sample Preparation System
- BD FACSLyric™ Cell Analyzer
- BD FACSMelody™ Cell Sorter
- BD FACSymphony™ Cell Analyzer
- BD LSRFortessa™ Cell Analyzer
- United States (English)
-
Change location/language
Old Browser
This page has been recently translated and is available in French now.
Looks like you're visiting us from {countryName}.
Would you like to stay on the current location site or be switched to your location?
Minimize Cross-laser Spillover. Optimize Panel Resolution.
| Format | Spectral | Conventional | Relative Brightness | Spillover (1-low, 4-high) | Alternative To |
|---|---|---|---|---|---|
| Violet Laser | |||||
| RV828 | ✓ | ‒ | 1 | Qdot™ 800, NovaFluor™ V800 | |
| Blue Laser | |||||
| RB545 | ✓ | ‒ | 1 | (Unique position) | |
| RB613 | ✓ | ✓ | 2 | PE-CF594, PE-Dazzle™ 594, BB630-P2, StarBright™ Blue 615 | |
| RB670 | ✓ | ✓ | 2 | PE-Cy5, BB660-P2, StarBright™ Blue 675 | |
| RB705 | ✓ | ✓ | 2 | PerCP-Cy5.5, BB700, StarBright™ Blue 700 | |
| RB744 | ✓ | ✓ | 1 | BB755-P | |
| RB780 | ✓ | ✓ | 1 | PE-Cy7, BB790-P | |
| RB824 | ✓ | ✓ | 1 | PerCP/Fire™ 806, StarBright™ Blue 810 | |
| Yellow-Green Laser | |||||
| RY586 | ✓ | ✓ | 1 | PE | |
| RY610 | ✓ | ✓ | 1 | PE-CF594, PE-Dazzle™ 594 | |
| RY655 | ✓ | ✓ | 3 | PE-Cy5, StarBright Yellow 665 | |
| RY703 | ✓ | ✓ | 2 | PE-Cy5.5, StarBright™ Yellow 720 | |
| RY743 | ✓ | ✓ | 2 | PE/Fire™ 744 | |
| RY775 | ✓ | ✓ | 2 | PE-Cy7, StarBright™ Yellow 800 | |
| Red Laser | |||||
| RR688 | ✓ | ‒ | 1 | Alexa Fluor™ 660, Spark NIR™ 685, NovaFluor™ R685, cFluor™ R685 | |
“The RB780 fluorochrome fits very well into the spectral gap of dyes primarily excited by the blue laser and can be separated beautifully from PE-Cy7 on instruments with blue and yellow-green lasers.”
“The RB780 fluorochrome fits very well into the spectral gap of dyes primarily excited by the blue laser and can be separated beautifully from PE-Cy7 on instruments with blue and yellow-green lasers.”
“I’m really excited about the BD Horizon RealBlue™ 780 Dye. The staining we have done so far with Ki-67 and Granzyme B can be seen very clearly, even with high dilutions.”
“I’m really excited about the BD Horizon RealBlue™ 780 Dye. The staining we have done so far with Ki-67 and Granzyme B can be seen very clearly, even with high dilutions.”
"BD Horizon RealYellow™ 586 (RY586) Reagents look like the best alternative for PE and will simplify panel design on conventional flow cytometers. They can also be an additional dye for spectral panel design.”
"BD Horizon RealYellow™ 586 (RY586) Reagents look like the best alternative for PE and will simplify panel design on conventional flow cytometers. They can also be an additional dye for spectral panel design.”
-
Brochures
-
BD Horizon RealBlue™ 545 Reagents
-
BD Horizon RealBlue™ 613 and BD Horizon RealYellow ™ 610
-
BD Horizon RealBlue™ 705 Reagents
-
BD Horizon RealBlue™ 744 Reagents
-
BD Horizon RealBlue™ 780 Reagents
-
BD Horizon RealYellow™ 586 Reagents
-
BD Horizon RealYellow™ 775 Reagents
-
BD Horizon RealYellow™ 703 Reagents
-
Performance Guide
BD flow cytometers are Class 1 Laser Products. For Research Use Only. Not for use in diagnostic or therapeutic procedures.
CF is a trademark of Biotium, Inc. Cy is a trademark of Global Life Sciences Solutions Germany GmbH or an affiliate doing business as Cytiva.