
-
Reagents
- Flow Cytometry Reagents
-
Western Blotting and Molecular Reagents
- Immunoassay Reagents
-
Single-Cell Multiomics Reagents
- BD® OMICS-Guard Sample Preservation Buffer
- BD® OMICS-One Protein Panels
- BD® AbSeq Assay
- BD® Single-Cell Multiplexing Kit
- BD Rhapsody™ ATAC-Seq Assays
- BD Rhapsody™ Whole Transcriptome Analysis (WTA) Amplification Kit
- BD Rhapsody™ TCR/BCR Next Multiomic Assays
- BD Rhapsody™ Targeted mRNA Kits
- BD Rhapsody™ Accessory Kits
-
Functional Assays
-
Microscopy and Imaging Reagents
-
Cell Preparation and Separation Reagents
-
Promotions
-
Spectral Sorter Promotion
-
BD Primer Program
-
New Lab Promotion
-
BD FACSLyric™ Flow Cytometers 50th Anniversary Promo
-
BD FACSAria™ Customer Loyalty Promotion
-
FlowJo™ Software Promotion
-
BD® Research Cloud Promotion
-
30% off + Free Shipping on BD Horizon Brilliant™ Violet and Ultraviolet Reagents!
-
30% off BD Horizon RealYellow ™ & BD Horizon RealBlue™ Reagents!
-
Spectral Sorter Promotion
-
Training
- Flow Cytometry Basic Training
-
Product-Based Training
- BD Accuri™ C6 Plus Cell Analyzer
- BD FACSAria™ Cell Sorter Cell Sorter
- BD FACSDiscover™ A8 Cell Analyzer Product Training
- BD FACSCanto™ Cell Analyzer
- BD FACSDiscover™ S8 Cell Sorter
- BD FACSDuet™ Sample Preparation System
- BD FACSLyric™ Cell Analyzer
- BD FACSMelody™ Cell Sorter
- BD FACSymphony™ Cell Analyzer
- BD LSRFortessa™ Cell Analyzer
- Advanced Training
-
- BD® OMICS-Guard Sample Preservation Buffer
- BD® OMICS-One Protein Panels
- BD® AbSeq Assay
- BD® Single-Cell Multiplexing Kit
- BD Rhapsody™ ATAC-Seq Assays
- BD Rhapsody™ Whole Transcriptome Analysis (WTA) Amplification Kit
- BD Rhapsody™ TCR/BCR Next Multiomic Assays
- BD Rhapsody™ Targeted mRNA Kits
- BD Rhapsody™ Accessory Kits
-
- BD Accuri™ C6 Plus Cell Analyzer
- BD FACSAria™ Cell Sorter Cell Sorter
- BD FACSDiscover™ A8 Cell Analyzer Product Training
- BD FACSCanto™ Cell Analyzer
- BD FACSDiscover™ S8 Cell Sorter
- BD FACSDuet™ Sample Preparation System
- BD FACSLyric™ Cell Analyzer
- BD FACSMelody™ Cell Sorter
- BD FACSymphony™ Cell Analyzer
- BD LSRFortessa™ Cell Analyzer
- United States (English)
-
Change country/language
Old Browser
This page has been recently translated and is available in French now.
Looks like you're visiting us from {countryName}.
Would you like to stay on the current country site or be switched to your country?
Expand your T cell research with confidence
The BD Horizon™ Human T Cell Backbone Panel consists of an optimized configuration of core markers specifically designed to expand your research with recommended fluorochrome drop-ins and enable flexibility in panel design without compromising resolution.
Fluorochromes were strategically selected so that up to five recommended drop-ins can be added with minimal impact to the backbone resolution and minimal panel design effort, allowing you to focus on marker selection.
Learn more from the BD Horizon™ Human T cell backbone panel brochure.


- Chapters
- descriptions off, selected
- captions settings, opens captions settings dialog
- captions off, selected
This is a modal window.
Beginning of dialog window. Escape will cancel and close the window.
End of dialog window.
This is a modal window. This modal can be closed by pressing the Escape key or activating the close button.
This is a modal window. This modal can be closed by pressing the Escape key or activating the close button.
Watch the webinar describing the use of the BD Horizon™ T Cell Backbone Panel for expanding your T cell research.
The BD Horizon™ Human T Cell Backbone Panel contains a set of markers that can be combined with up to five additional fluorochromes without impacting resolution
Marker | Clone | Fluorochrome |
---|---|---|
CD3 | UCHT1 | BV510 |
CD4 | SK3 | BV786 |
CD8 | RPA-T8 | R718 |
CD45RA | HI100 | PE-Cy7 |
CD197 (CCR7) | 2-L1-A | BV711 |
BD Horizon™ Brilliant Stain Buffer is included to provide optimal reagent performance.
Examples of recommended drop-in fluorochromes
Laser | Drop-in |
---|---|
Violet 405 nm | BV421/V450/Pacific Blue™ |
Blue 488 nm | FITC/BB515/Alexa Fluor™ 488/PE |
Yellow-Green 561 nm | PE/RY586 |
Red 640 nm | APC/Alexa Fluor™ 647 |
UV 355 nm | BUV395 |
Drop-in reagents not included in backbone kit.
AF: Alexa Fluor™ Reagent
BB: BD Horizon Brilliant™ Blue Reagent, BUV: BD Horizon Brilliant™ Ultraviolet Reagent
BV: BD Horizon Brilliant™ Violet Reagent, R: BD Horizon™ Red Reagent
RY: BD Horizon RealYellow™ Reagent
The BD Horizon RealYellow™ (RY) 586 Fluorochrome can be used as an alternative to PE when excited off the yellow-green laser. Simultaneous use of PE off the blue laser and RY586 off the yellow-green laser is not recommended.
The BD Horizon™ Human T Cell Backbone Panel offers increased flexibility and fewer design challenges
High Performance
- Strategically designed to be complemented with up to five drop-in markers with no resolution impact to the backbone or the selected drop-ins
- Verified protocols to ensure optimal performance
- Consistent performance across instruments with different optical configurations


Performance
Performance of BD HorizonTM Human T Cell Backbone Panel including drop-in configurations


Applications
Identification of FoxP3+ Treg subsets

B) Clear resolution of all the subsets of interest was observed on fixed and permeabilized PMBCs from N = 3 healthy donors. Samples were acquired on a 4-laser BD FACSymphony™ A1 Cell Analyzer and analyzed with FlowJo™ Software v10.8.1.
Upregulation of inhibitory receptors



BD Horizon™ Human T Cell Backbone Panel Kit
Order Your Kit Today
BD flow cytometers are Class 1 Laser Products.
For Research Use Only. Not for use in diagnostic or therapeutic procedures.
Alexa Fluor and Pacific Blue are trademarks of Thermo Fisher Scientific. Cy is a trademark of Global Life Sciences Solutions Germany GmbH or an affiliate doing business as Cytiva.