Skip to main content Skip to navigation

BD FACSLyric™ Flow Cytometry System

Discover how this flow cytometry system can transform your lab with outstanding performance, automation and standardization.

Discover the BD FACSLyric™ Flow Cytometer difference.

  • Witness results you have never seen before through high sensitivity and improved resolution
  • Streamline your lab workflow through flexibility and automation, enabling efficiency and productivity
  • Achieve automated standardization through highly reproducible results and enable collaboration through assay portability

 

See how the BD FACSLyric™ System can transform your lab.

 

 
performance1

Features

Discover the BD FACSLyric™ Flow Cytometry System—A Next-Generation Flow Cytometer

Built on a foundation of excellence, experience and expertise, the BD FACSLyric™ Flow Cytometry System is a new standard for cell analysis, transforming the way your lab does flow cytometry. As with all BD instruments, the BD FACSLyric™ Flow Cytometry System is backed by 40 years of BD expert training, service and support—so there’s no limit to your potential.

 

The Power of the BD FACSLyric Flow Cytometer

 

  • 4-, 6-, 8-, 10- and 12-color configurations. Onsite upgradeable to adapt to your lab's changing needs
  • Up to 3 lasers—blue, red and violet—12 fluorescence channels and 14 parameters
  • 35,000 events per second maximum acquisition rate; no limit on number of events acquired
  • Automated single-tube QC with BD® CS&T Beads
  • Fluorescence compensation required only every 60 days, improving efficiency and productivity
  • 21 different loading options: plates or tubes; built-in flexibility with BD FACS Universal Loader
  • Powered by the BD FACSuite™ Acquisition and Analysis Application, whose password protection, audit trail, electronic signatures and IQ/OQ procedures assist in supporting U.S, FDA 21 CFR Part 11 compliance
  • BD FACSLink Laboratory Information System (LIS) Interface and BD Assurity Linc Remote Systems Management Software streamline your workflow and help improve productivity through seamless integration
Video Player is loading.
Current Time 0:00
Duration 0:00
Loaded: 0%
Stream Type LIVE
Remaining Time 0:00
 
1x
    • Chapters
    • descriptions off, selected
    • captions off, selected

      Watch the video about simple assay transfer on the BD FACSLyric Cell Analyzer.

      Performance

      A new standard delivering outstanding performance and standardization within and between instruments

      The BD FACSLyric™ Flow Cytometry System is a high-performance, highly sensitive flow cytometer that demonstrates exceptional resolution and improved separation to make dim and rare cell populations easier to resolve.

       

       

       

      Highly reproducible results between instruments drive standardization.

       

      BD FACSLyric™ System Variance (CVs)
      15 BD FACSLyric™ Systems: Lyse/Wash settings and BD FC® Beads
      Blue Laser %CV
      FITC 4.2
      PE 4.4
      PE-Cy7 4.8
      PerCP 10.2
      PerCP-Cy5.5 7.9
      Red Laser %CV
      APC 5.3
      APC-Cy7 4.1
      APC-H7 3.9
      APC-R700 4.2
         
      Violet Laser %CV
      BD Horizon™ V450 11.1
      BD Horizon™ V500 11
      BD Horizon™ BV605 13.6
      BD Horizon™ BV711 7.5
      BD Horizon™ BV786 15.3

       

      Between-instrument reproducibility of target MFI values on the BD FACSLyric™ System

      Lyse/wash assay settings were imported across 15 instruments to show effects of standardization on beads. The CVs of the fluorescence intensity across all channels varies by less than 15.3%. Daily QC with one lot of BD® Cytometer Setup & Tracking Beads was run on fifteen BD FACSLyric™ Flow Cytometers. For each instrument, the PMTV gains were automatically adjusted to meet the target values. BD® FC Beads acquired on each BD FACSLyric™ Instrument. The MFI of positive populations was measured for all parameters across all instruments. The %CV is shown. The data for this internal study were acquired using BD® FC Beads across 15 BD FACSLyric™ Instruments. Greater between-instrument variability could be observed when running biological samples, when using non BD reagents or when comparing fewer instruments. 

      prev
      next

      "BD is positioned with BD® CS&T and BD® FC Bead technology to enable instrument standardization simply from day to day, instrument to instrument, and lab to lab."

       

      "BD is positioned with BD® CS&T and BD® FC Bead technology to enable instrument standardization simply from day to day, instrument to instrument, and lab to lab."

       

      Dr. Lili Wang
      NIST
      Gaithersburg, MD
      prev
      next

      BD FACSLyric™ Flow Cytometers are Class 1 Laser Products.

      The BD FACSLyric™ Flow Cytometer is For Research Use Only. Not for use in diagnostic or therapeutic procedures. Cy is a trademark of Global Life Sciences Solutions Germany GmbH or an affiliate doing business as Cytiva.