Skip to main content Skip to navigation
RY 586 and RB 780 Banner

Superior Alternative to PerCP-Cy5.5 and BD Horizon Brilliant™ Blue 700 (BB700) Reagents

 

BD Horizon RealBlue 705 (RB705) Reagents leverage an innovative laser-specific fluorochrome, excited primarily by the 488-nm blue laser to offer:

  • Minimal cross-laser excitation off the 561-nm yellow-green laser
  • A bright fluorochrome to support the detection of low-expression surface and intracellular markers
  • Reduced background compared to BB700 with no additional wash recommended
 
RB705 vials
performance1

RB705 Reagents Can Be Used Instead of PerCP-Cy5.5 or BB700 on Conventional Flow Cytometers or with PerCP-Cy5.5 or BB700 on Spectral Flow Cytometers

RB705 specifications

 

FormatEx MaxEm MaxSpectralConventionalRelative BrightnessSpillover* (1 = low, 4 = high)Alternative To
RB705498 nm707 nm 2PerCP-Cy5.5,
BB700,
StarBright Blue 700,
NovaFluor Blue 690,
cFluor™ B690
 
*Value may vary based on instrument configuration and settings. Spillover ranking is based on cross-laser excitation on five-laser spectral instruments and does not take into account spillover into adjacent detectors.
 

View Products

Performance

BD Horizon RealBlue 705 Reagents Provide Minimal Cross-laser Excitation Off the 561-nm Yellow-green Laser


RB705 has reduced cross-laser excitation

 

RB705 Minimum Cross Laser Excitation

Normalized emission profiles of RB705, BB700 and PerCP-Cy5.5 fluorochromes. Human CD4 SK3 antibody acquired on a BD FACSDiscoverS8 Cell Sorter. 

Compared to PerCP-Cy5.5 and BB700, RB705 is a brighter fluorochrome and has lower spillover spread into the corresponding yellow-green detector
RB705 Spillover Comparison Data

Human whole blood was stained with BD Horizon BB700 Reagent, PerCP-Cy5.5 or RB705 Human CD4 (clone SK3), acquired on a BD FACSymphony™ A5 SE Cell Analyzer and compensated with FlowJo Software. Note that spillover spread is a function of reagent brightness and antigen density, similar spillover spreading observed at higher brightness indicates lower spillover spread.

 

View Products

Applications

Multicolor Flow Cytometry

BD Horizon RB705 Reagents Resolve Well in a 12-color T Cell Inhibitory Panel Acquired on the BD FACSLyric Cell Analyzer

 

Gating scheme of T cell subsets
12-Color-Tcell-Inhibitory-Panel-Gating

Healthy PBMC were stained with a 12-color inhibitory T cell panel and acquired on the BD FACSLyric Flow Cytometry System. Labels on top of each plot show the parental gate from which plots are derived; numbers in each quadrant represent the frequency of cell population; T cell subsets are identified as N, naïve; CM, central memory; EM, effector memory; EMRA, effector memory RA+; and SCM, stem cell like memory.

BD Horizon™ RB705 Reagents resolve low expression surface markers
CD8 T cell Subsets Inhibitory Marker Expression

Histogram overlays depict expression pattern of inhibitory receptors TIM-3, CTLA-4, TIGIT, BTLA, LAG-3 and PD-1 on CD8+ T naïve, stem cell memory, central memory, effector memory and effector memory RA cell subsets.

T cell subsets after activation
T cell subsets after activation

Bivariate plots show CD4/CD8 T cell population derived from activated T cells on Day 3 following immunostaining by a 12-color RB705 panel. Control T cells are from the same donor subjected to similar culture conditions but without activation. Samples were acquired on a 3-laser BD FACSLyric™ Flow Cytometry System.

T cell inhibitory markers are upregulated upon activation
T cell inhibitory markers are upregulated upon activation

Histogram overlays show expression of T cell inhibitory markers derived from CD4+ resting T cells (deep gray shade) or CD4 activated T cells (deep colored), CD8+ resting T cells (light gray) CD8+ activated T cells (light colored) stained with a 12-color RB705 panel.

BD Horizon RB705 Reagents Have Excellent Resolution as Demonstrated in a 17-color Spectral Flow Cytometry Panel Acquired on the BD FACSymphony A5 SE Cell Analyzer

 

Gating strategy for detection of T cell subsets in activated T cells
T cell subset detection

Peripheral blood mononuclear cells were isolated and loaded with Violet Proliferation Dye 450 before stimulation with or without staphylococcal enterotoxin B (SEB, 1 µg/mL) and CD28 (1 µg/mL) for 3 days. PMA (10 ng/mL) and ionomycin (1 µg/mL) were added to the Stimulated + Boost group 4 hours before collecting cells for staining. Cells were then stained with Fixable Viability Stain 620 and antibodies against cell surface markers prior to fixing and permeabilizing with BD Cytofix/CytopermFixation/Permeabilization Buffer. Fixed and permeabilized cells were then stained with intracellular antibodies. Stained cells were analyzed on a BD FACSymphony A5 SE Cell Analyzer. Gating strategy for detection of T cell subsets after exclusion of doublets, dead cells and lineage-positive cells. CD3+ T cells were selected and divided into CD4+ or CD8+ cells. CD8+ T cells were further evaluated for activation stage based on their expression of CD25 and CD69. Samples were acquired on a BD FACSymphonyA5 SE Cell Analyzer and analyzed with FlowJo Software.

Expression of inhibitory receptors at different activation levels of CD8+ T cells
Expression of inhibitory receptors at different activation levels of CD8+ T cells

Histogram overlays showing expression of inhibitory receptors on CD8+ T cell subsets from the Stimulated group. Total CD8+ T cells from the unstimulated group (top, dark green).

Cytokines expression at different activation stages of CD8+ T cells
Cytokines expression at different activation stages of CD8+ T cells

Histogram overlays showing expression of cytokines on CD8+ T cell subsets from the Stimulated + Boost group. Total CD8+ T cells from the unstimulated group (top, dark green).

Fluorochrome marker assignment for a 17-color spectral flow cytometry panel

 

 SpecificityCloneFluorochrome
UV
355 nm

CD25

M-A251

BUV395

CD56

NCAM16.2

BUV496

CD20

L27

BUV496

CD19

SJ25C1

BUV496

CD16

3G8

BUV496

CD14

M5E2

BUV496

AutoF

N/A

N/A

TIM-3

7D3

BUV615

CD4

SK3

BUV805

Violet
405 nm

TNF

MAb11

BV421

VPD450

N/A

N/A

CD3

UCHT1

BV510

CD134

ACT35

BV786

Blue
488 nm

IFNγ

B27

FITC

CD69

FN50

RB545

FVS620

N/A

N/A

LAG-3

T47-530

RB705

PD-1

EH12.1

RB744

II-2

MQ1-17H12

RB780

Yellow-Green
561 nm

CTLA-4

BNI3

RY586

Red
640 nm

GranzB

GB11

AF647

CD8

SK1

APC-H7


Fluorochrome marker assignment for a 17-color spectral flow cytometry panel acquired on the BD FACSymphonyA5 SE Cell Analyzer.


View Products

Buffer Compatibility

BD Horizon RealBlue™ 705 Reagents Are Compatible with a Broad Range of Fixation and Permeabilization Systems

 

BuffersResults
BD FACS™ Lysing Solution and BD Pharm Lyse™ Lysing BufferCompatible
CellBox™ Blocking BufferCompatible
BD Cytofix™ Fixation BufferStable at least 24 hours
1% PFAStable at least 24 hours
BD Cytofix/Cytoperm™ Fixation and Permeabilization SolutionCompatible with antibody staining before and after fixation
BD FACS™ Permeabilizing Solution 2Compatible with antibody staining before and after fixation
BD Phosflow™ Perm Buffer IIICompatible with antibody staining before and after fixation
EDTA and HeparinCompatible
BD Horizon™ Brilliant Stain Buffer (BSB)Compatible
 

   

    

BD flow cytometers are Class 1 Laser Products. For Research Use Only. Not for use in diagnostic or therapeutic procedures.

The BD FACSLyric™ Flow Cytometer is for Research Use Only with BD FACSuite™ Application for up to 12 colors. Not for use in diagnostic or therapeutic procedures.

CF is a trademark of Biotium, Inc. Cy is a trademark of Global Life Sciences Solutions Germany GmbH or an affiliate doing business as Cytiva. CellBlox is a trademark of Thermo Fisher Scientific.