-
Training
- Flow Cytometry Basic Training
-
Product-Based Training
- BD Accuri™ C6 Plus Cell Analyzer
- BD FACSAria™ Cell Sorter Cell Sorter
- BD FACSCanto™ Cell Analyzer
- BD FACSDiscover™ A8 Cell Analyzer
- BD FACSDiscover™ S8 Cell Sorter
- BD FACSDuet™ Sample Preparation System
- BD FACSLyric™ Cell Analyzer
- BD FACSMelody™ Cell Sorter
- BD FACSymphony™ Cell Analyzer
- BD LSRFortessa™ Cell Analyzer
- Advanced Training
Old Browser
This page has been recently translated and is available in French now.
Looks like you're visiting us from {countryName}.
Would you like to stay on the current location site or be switched to your location?
Stat1 (pY701) (4a)
Stat1 (pY701) A488
| Perm I | Perm II | Perm III | Perm IV (0.5x) | Perm IV (1.0x) | |
|---|---|---|---|---|---|
Control IFN-α |
|
|
|
|
|
| Perm I | Perm II | Perm III | Perm IV (0.5x) | Perm IV (1.0x) | |
|---|---|---|---|---|---|
| Control | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 |
| IFN-α | 2.37 | 7.95 | 16.27 | 5.69 | 16.21 |
Stat1 (pY701) PE
| Perm I | Perm II | Perm III | Perm IV (0.5x) | Perm IV (1.0x) | |
|---|---|---|---|---|---|
Control IFN-α |
|
|
|
|
|
| Perm I | Perm II | Perm III | Perm IV (0.5x) | Perm IV (1.0x) | |
|---|---|---|---|---|---|
| Control | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 |
| IFN-α | 2.91 | 6.5 | 10.26 | 5.88 | 9.56 |
Stat1 (pY701) PerCP-Cy5.5
| Perm I | Perm II | Perm III | Perm IV (0.5x) | Perm IV (1.0x) | |
|---|---|---|---|---|---|
Control IFN-α |
|
|
|
|
|
| Perm I | Perm II | Perm III | Perm IV (0.5x) | Perm IV (1.0x) | |
|---|---|---|---|---|---|
| Control | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 |
| IFN-α | 2.78 | 6.55 | 11.94 | 6.65 | 15.0 |
Stat1 (pY701) A647
| Perm I | Perm II | Perm III | Perm IV (0.5x) | Perm IV (1.0x) | |
|---|---|---|---|---|---|
Control IFN-α |
|
|
|
|
|
| Perm I | Perm II | Perm III | Perm IV (0.5x) | Perm IV (1.0x) | |
|---|---|---|---|---|---|
| Control | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 |
| IFN-α | 2.69 | 11.19 | 20.17 | 9.62 | 23.73 |
Lymphocytes
Perm Buffer IV 1X vs. 0.5X:
Perm Buffer IV (provided as a 10X stock solution) may be used at a 1X or 0.5X concentration. The higher (1X) concentration provides optimal resolution of certain intracellular phosphoprotein stains but might result in increased cell loss and decreased ability to stain certain cell surface markers.
For Research Use Only. Not for use in diagnostic or therapeutic procedures.
Alexa Fluor, Pacific Blue and Texas Red are trademarks of Life Technologies Corporation. Cy is a trademark of Global Life Sciences Solutions Germany GmbH or an affiliate doing business as Cytiva. AmCyan is a trademark of Takarabio Inc. BD-40149 (v1.0) 0721