-
Instruments
-
Flow Cytometers
- BD FACSDiscover™ Spectral Platforms
-
BD FACSLyric™ Clinical Cell Analyzer
-
BD FACSMelody™ Cell Sorter
-
BD Accuri™ C6 Plus
- BD FACSymphony™ Cell Analyzers & Sorters Platform
- BD FACSAria™ Cell Sorter Platform
-
BD FACSCelesta™ Cell Analyzer
- BD LSRFortessa™ Flow Cytometer Platform
-
BD FACSCanto™ Clinical Flow Cytometry System
- Clinical Sample Prep Systems
- Single-Cell Multiomics Systems
-
Flow Cytometers
-
Reagents
-
Flow Cytometry Reagents
-
Clinical Diagnostics
- ASR Single Color Antibodies
- Buffers and Supporting Reagents (IVD, CE-IVD)
- Process and Quality Controls
- Single Color Antibodies ASR IVD CE IVD
- Multicolor Cocktails and Kits IVD CE IVDs
- OneFlow
- Stem Cell Enumeration Kit Reagents
- Leucocount ™ Kit | BD Biosciences
- BD Multitest™ 6-Color TBNK Kit | BD Biosciences
- Clinical Discovery
-
Research Reagents
- Quality and Reproducibility
- Single Color Antibodies RUO
- Panels Multicolor Cocktails RUO
- Flow Cytometry Controls and Lysates
- buffers and Supporting Reagents RUO
- Cell Function Analysis Stains Dyes
- Single Color Antibodies
- Compensation Beads
- BD Horizon™ Human T Cell Backbone Panel
- BD Pharmingen™ MonoBlock™ Leukocyte Staining Buffer
- BV605 Transition
- BD Horizon Brilliant™ Dyes
- Single-Color Antibodies for Flow Cytometry (RUO)
-
BD Horizon™ Real Dyes for Flow Cytometry
- BD Horizon RealYellow™ 610
- BD Horizon RealRed™ 688 Reagents
- BD Horizon RealYellow™ 703
- BD Horizon RealBlue™ 670 for Flow Cytometry
- BD Horizon RealYellow™ 743
- BD Horizon RealBlue™ 780 for Flow Cytometry
- BD Horizon RealBlue™ 575 for Flow Cytometry | BD Real Dyes
- BD Horizon RealYellow™ 586
- BD Horizon RealBlue™ 824 for Flow Cytometry
- BD Horizon RealViolet™ 828 for Flow Cytometry
- BD Horizon RealViolet™ 544 for Flow Cytometry | BD Real Dyes
- BD Horizon RealViolet™ 544 for Flow Cytometry | BD Real Dyes
-
Clinical Diagnostics
-
Western Blotting and Molecular Reagents
- Immunoassay Reagents
-
Single-Cell Multiomics Reagents
-
BD OMICS-Guard™ CRYO Preservation Buffer
-
BD OMICS-Guard™ Sample Preservation Buffer
-
BD OMICS-One™ Protein Panels
- BD® OMICS-One Tumor Protein Panel
- BD® OMICS-One T-Cell Protein Panel
- BD® OMICS-One B-Cell Protein Panel
- BD® OMICS-One Adaptive Protein Panel
- BD® OMICS-One Immune Profiler Protein Panel
- BD® OMICS-One Immuno-Oncology Protein Panel
- BD® OMICS-One NK-Cell Protein Panel
- BD® OMICS-One APC/Myeloid-Cell Protein Panel
- BD® OMICS-One Innate Protein Panel
- BD® OMICS-One Innate Immuno-Oncology Protein Panel
- BD® OMICS-One Comprehensive Immuno-Oncology Protein Panel
- BD® AbSeq Assay
- BD® Single-Cell Multiplexing Kit
-
BD OMICS-One™ WTA Next Assay
-
BD Rhapsody™ ATAC-Seq Assays
-
BD Rhapsody™ TCR/BCR Next Multiomic Assays
-
BD Rhapsody™ Targeted mRNA Kits
-
BD Rhapsody™ Accessory Kits
-
BD OMICS-Guard™ CRYO Preservation Buffer
- Functional Assays
-
Microscopy and Imaging Reagents
-
Cell Preparation and Separation Reagents
-
Dehydrated Culture Media
-
Flow Cytometry Reagents
-
BD Biosciences Training Program
- Flow Cytometry Basic Training
-
Product-Based Training
- BD Accuri™ C6 Plus Cell Analyzer
- BD FACSAria™ Cell Sorter Cell Sorter
- BD FACSCanto™ Cell Analyzer
- BD FACSDiscover™ A8 Cell Analyzer
- BD FACSDiscover™ S8 Cell Sorter
- BD FACSDuet™ Sample Preparation System
- BD FACSLyric™ Cell Analyzer
- BD FACSMelody™ Cell Sorter
- BD FACSymphony™ Cell Analyzer
- BD LSRFortessa™ Cell Analyzer
- Advanced Training
-
-
-
-
- ASR Single Color Antibodies
- Buffers and Supporting Reagents (IVD, CE-IVD)
- Process and Quality Controls
- Single Color Antibodies ASR IVD CE IVD
- Multicolor Cocktails and Kits IVD CE IVDs
- OneFlow
- Stem Cell Enumeration Kit Reagents
- Leucocount ™ Kit | BD Biosciences
- BD Multitest™ 6-Color TBNK Kit | BD Biosciences
-
- Quality and Reproducibility
- Single Color Antibodies RUO
- Panels Multicolor Cocktails RUO
- Flow Cytometry Controls and Lysates
- buffers and Supporting Reagents RUO
- Cell Function Analysis Stains Dyes
- Single Color Antibodies
- Compensation Beads
- BD Horizon™ Human T Cell Backbone Panel
- BD Pharmingen™ MonoBlock™ Leukocyte Staining Buffer
- BV605 Transition
- BD Horizon Brilliant™ Dyes
- Single-Color Antibodies for Flow Cytometry (RUO)
-
- BD Horizon RealYellow™ 610
- BD Horizon RealRed™ 688 Reagents
- BD Horizon RealYellow™ 703
- BD Horizon RealBlue™ 670 for Flow Cytometry
- BD Horizon RealYellow™ 743
- BD Horizon RealBlue™ 780 for Flow Cytometry
- BD Horizon RealBlue™ 575 for Flow Cytometry | BD Real Dyes
- BD Horizon RealYellow™ 586
- BD Horizon RealBlue™ 824 for Flow Cytometry
- BD Horizon RealViolet™ 828 for Flow Cytometry
- BD Horizon RealViolet™ 544 for Flow Cytometry | BD Real Dyes
- BD Horizon RealViolet™ 544 for Flow Cytometry | BD Real Dyes
-
-
-
-
- BD® OMICS-One Tumor Protein Panel
- BD® OMICS-One T-Cell Protein Panel
- BD® OMICS-One B-Cell Protein Panel
- BD® OMICS-One Adaptive Protein Panel
- BD® OMICS-One Immune Profiler Protein Panel
- BD® OMICS-One Immuno-Oncology Protein Panel
- BD® OMICS-One NK-Cell Protein Panel
- BD® OMICS-One APC/Myeloid-Cell Protein Panel
- BD® OMICS-One Innate Protein Panel
- BD® OMICS-One Innate Immuno-Oncology Protein Panel
- BD® OMICS-One Comprehensive Immuno-Oncology Protein Panel
-
-
-
- United States (English)
-
Change location/language
Old Browser
This page has been recently translated and is available in French now.
Looks like you're visiting us from {countryName}.
Would you like to stay on the current location site or be switched to your location?
BD Pharmingen™ PE Rat IgG1, κ Isotype Control
Clone R3-34 (RUO)
Regulatory Status Legend
Any use of products other than the permitted use without the express written authorization of Becton, Dickinson and Company is strictly prohibited.
Preparation And Storage
Recommended Assay Procedures
Immunofluorescent Staining for Intracellular Cytokines: The PE-R3-34 immunoglobulin is a suitable rat IgG1 isotype control for assessing the level of background staining on paraformaldehyde-fixed/saponin-permeabilized mouse or human cells for flow cytometric analysis. This 100 Test Size formulation of the PE-conjugated R3-34 antibody has been pre-titrated to assure effective results as an Ig isotype control for our Test Sized PE-conjugated Rat IgG1 antibodies using 20µl/1 x 10^6 cells. The intracellular cytokine staining techinque and use of blocking controls are described in detail by C. Prussin and D. Metcalfe. For specific methodology, please visit the protocols section or chapter on intracellular staining in the Immune Function Handbook, both of which are posted on our web site, www.bdbiosciences.com.
Important Note: This pre-titered antibody solution does not contain a cell permeabilization agent. It is necessary to include a cell permeabilization agent when using the pre-titered antibody solution to stain fixed and permeabilized cells. BD Perm/Wash™ Buffer (Cat. No. 554723) contains the permeabilization agent saponin and is useful for this purpose as described in the Usage section below.
Usage
1. Resuspend 1 x 10^6 fixed and permeabilized cells in 20 µl of the pre-titered antibody solution and 30 µl of 1 x BD Perm/Wash™ Buffer (Cat. No. 554723).
2. Incubate the cell suspension for 15 minutes (at RT or 4°C).
3. Wash twice in 100 µl of 1 x BD Perm/Wash Buffer (Cat. No. 554723).
Bead-based compensation or unmixing controls, such as BD® CompBeads or BD™ SpectraComp™, can be used as surrogates to assess fluorescence spillover when bound to fluorochrome-conjugated antibodies. Although these beads have spectral properties similar to cells, variations in spectral emission may occur, resulting in differing spillover values compared to biological controls. Therefore, it is considered best practice to compare the spillover obtained from cells and bead-based controls when using BD® CompBeads or BD™ SpectraComp™ for the first time, to ensure they are appropriate for the intended application.
Product Notices
- Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
- Source of all serum proteins is from USDA inspected abattoirs located in the United States.
- Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
- This reagent has been pre-diluted for use at the recommended Volume per Test. We typically use 1 × 10^6 cells in a 100-µl experimental sample (a test).
- For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
- An isotype control should be used at the same concentration as the antibody of interest.
- Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
- For U.S. patents that may apply, see bd.com/patents.
Companion Products
Following immunization of a rat with mouse immunoglobulin (Ig), the Ig from the R3-34 hybridoma was identified as a non-reactive clone. The R3-34 immunoglobulin was selected as an Ig isotype control following screening for low background staining on a variety of mouse and human cells and tissues.
Development References (1)
-
Prussin C, Metcalfe DD. Detection of intracytoplasmic cytokine using flow cytometry and directly conjugated anti-cytokine antibodies. J Immunol Methods. 1995; 188(1):117-128. (Methodology). View Reference
Please refer to Support Documents for Quality Certificates
Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described
Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims. Comparisons are not made against non-BD technologies, unless otherwise noted.
For Research Use Only. Not for use in diagnostic or therapeutic procedures.