Skip to main content Skip to navigation
PE Hamster Anti-Mouse CD29
PE Hamster Anti-Mouse CD29
Flow cytometric analysis of CD29 on mouse splenocytes.  Splenocytes from BALB/c mice were stained either with a PE Hamster IgG2, λ Isotype Control (Cat. No. 553965; dashed line histogram) or with the PE Hamster Anti-Mouse CD29 antibody (Cat. No. 562801; solid line histogram). Flow cytometric histograms were derived from gated events with the forward and side light-scattering characteristics of viable cells. Flow cytometry was performed on a BD™ LSR II Flow Cytometry System.
Flow cytometric analysis of CD29 on mouse splenocytes.  Splenocytes from BALB/c mice were stained either with a PE Hamster IgG2, λ Isotype Control (Cat. No. 553965; dashed line histogram) or with the PE Hamster Anti-Mouse CD29 antibody (Cat. No. 562801; solid line histogram). Flow cytometric histograms were derived from gated events with the forward and side light-scattering characteristics of viable cells. Flow cytometry was performed on a BD™ LSR II Flow Cytometry System.
Product Details
Down Arrow Up Arrow


BD Pharmingen™
Itgb1; Integrin beta-1; Fnrb; gpIIa; VLA-4 subunit beta
Mouse (QC Testing), Rat (Tested in Development)
Armenian Hamster IgG2, λ1
Purified mouse VLA-4
Flow cytometry (Routinely Tested)
0.2 mg/ml
16412
AB_2737806
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


Preparation And Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated with R-PE under optimum conditions, and unconjugated antibody and free PE were removed.

Product Notices

  1. Since applications vary, each investigator should titrate the reagent to obtain optimal results.
  2. An isotype control should be used at the same concentration as the antibody of interest.
  3. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  4. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  5. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  6. Species cross-reactivity detected in product development may not have been confirmed on every format and/or application.
  7. Although hamster immunoglobulin isotypes have not been well defined, BD Biosciences Pharmingen has grouped Armenian and Syrian hamster IgG monoclonal antibodies according to their reactivity with a panel of mouse anti-hamster IgG mAbs. A table of the hamster IgG groups, Reactivity of Mouse Anti-Hamster Ig mAbs, may be viewed at http://www.bdbiosciences.com/documents/hamster_chart_11x17.pdf.
562801 Rev. 1
Antibody Details
Down Arrow Up Arrow
HM β1-1

The HM β1-1 monoclonal antibody specifically binds to the 130-kDa integrin β1 chain (CD29). CD29 is expressed on the cell surface as a heterodimer with one of the distinct integrin-α chains. With α1 through α6 (CD49a through CD49f), it forms the VLA-1 through VLA-6 complexes, respectively, and with αv (CD51), it forms αvβ1 integrin. It also associates with the integrin α7 α8, and α9 chains in non-lymphoid tissues. As a result, CD29 has a broad tissue distribution, including lymphocytes, endothelia, smooth muscle, epithelia, and oocytes. This hamster mAb to a mouse leukocyte antigen has been observed to crossreact with similar populations of rat leukocytes. Source of the immunogen was purified mouse VLA-4 (α4β1, CD49d/CD29).

562801 Rev. 1
Format Details
Down Arrow Up Arrow
PE
R-Phycoerythrin (PE), is part of the BD family of Phycobiliprotein dyes. This fluorochrome is a multimeric fluorescent phycobiliprotein with excitation maximum (Ex Max) of 496 nm and 566 nm and an emission maximum (Em Max) at 576 nm. PE is designed to be excited by the Blue (488 nm), Green (532 nm) and Yellow-Green (561 nm) lasers and detected using an optical filter centered near 575 nm (e.g., a 575/26-nm bandpass filter). As PE is excited by multiple lasers, this can result in cross-laser excitation and fluorescence spillover on instruments with various combinations of Blue, Green, and Yellow-Green lasers. Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
altImg
PE
Yellow-Green 488 nm, 532 nm, 561 nm
496 nm, 566 nm
576 nm
562801 Rev.1
Citations & References
Down Arrow Up Arrow

Development References (6)

  1. Jacobsen K, Miyake K, Kincade PW, Osmond DG.. Highly restricted expression of a stromal cell determinant in mouse bone marrow in vivo. J Exp Med. 1992; 176(4):927-935. (Biology). View Reference
  2. Mendrick DL, Kelly DM. Temporal expression of VLA-2 and modulation of its ligand specificity by rat glomerular epithelial cells in vitro. Lab Invest. 1993; 69(6):690-702. (Clone-specific: Blocking). View Reference
  3. Noto K, Kato K, Okumura K, Yagita H. Identification and functional characterization of mouse CD29 with a mAb. Int Immunol. 1995; 7(5):835-842. (Immunogen: Blocking, Immunoprecipitation, Inhibition). View Reference
  4. Springer TA. Adhesion receptors of the immune system. Nature. 1990; 346(6283):425-434. (Biology). View Reference
  5. Wadsworth SA, Chang AC, Hong MJ, Halvorson MJ, Otto S, Coligan JE. Expression of a novel integrin beta 1 chain epitope and anti-beta 1 antibody-mediated enhancement of fibronectin binding are dependent on the stage of T cell differentiation. J Immunol. 1995; 154(5):2125-2133. (Biology). View Reference
  6. Wu X, Miyake K, Medina KL, Kincade PW, Gimble JM. Recognition of murine integrin beta 1 by a rat anti-stromal cell monoclonal antibody. Hybridoma. 1994; 13(5):409-416. (Biology). View Reference
View All (6) View Less
562801 Rev. 1

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.