Skip to main content Skip to navigation
BV605 Mouse Anti-Human CD15
BV605 Mouse Anti-Human CD15
Multiparameter flow cytometric analysis of CD15 expression on Human peripheral blood leukocyte populations. Human whole blood was stained with either BD Horizon™ BV605 Mouse IgG1, κ Isotype Control (Cat No. 562652; Left Plot) or BD Horizon™ BV605 Mouse Anti-Human CD15 antibody (Cat No. 567962/567963; Right Plot). The erythrocytes were lysed with BD FACS™ Lysing Solution (Cat. No. 349202). A bivariate pseudocolor density plot showing the correlated expression of CD15 (or Ig Isotype control staining) versus side light-scatter signals (SSC-A) was derived from gated events with the forward and side light-scatter characteristics of intact leukocytes. Flow cytometry and data analysis were performed using a BD LSRFortessa™ X-20 Cell Analyzer System and FlowJo™ Software.
Multiparameter flow cytometric analysis of CD15 expression on Human peripheral blood leukocyte populations. Human whole blood was stained with either BD Horizon™ BV605 Mouse IgG1, κ Isotype Control (Cat No. 562652; Left Plot) or BD Horizon™ BV605 Mouse Anti-Human CD15 antibody (Cat No. 567962/567963; Right Plot). The erythrocytes were lysed with BD FACS™ Lysing Solution (Cat. No. 349202). A bivariate pseudocolor density plot showing the correlated expression of CD15 (or Ig Isotype control staining) versus side light-scatter signals (SSC-A) was derived from gated events with the forward and side light-scatter characteristics of intact leukocytes. Flow cytometry and data analysis were performed using a BD LSRFortessa™ X-20 Cell Analyzer System and FlowJo™ Software.
Product Details
Down Arrow Up Arrow


BD Horizon™
LeX; Lewis X; SSEA-1
Human (QC Testing)
Mouse BALB/c IgG1, κ
Human Polymorphonuclear Leucocytes
Flow cytometry (Routinely Tested)
5 µl
V MA088
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


Preparation And Storage

The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated to the dye under optimum conditions and unconjugated antibody and free dye were removed. Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze.

Recommended Assay Procedures

   BD® CompBeads can be used as surrogates to assess fluorescence spillover (Compensation). When fluorochrome conjugated antibodies are bound to CompBeads, they have spectral properties very similar to cells.  However, for some fluorochromes there can be small differences in spectral emissions compared to cells, resulting in spillover values that differ when compared to biological controls. It is strongly recommended that when using a reagent for the first time, users compare the spillover on cells and CompBead to ensure that BD® CompBeads are appropriate for your specific cellular application.

   For optimal and reproducible results, BD Horizon Brilliant™ Stain Buffer should be used anytime BD Horizon Brilliant™ dyes are used in a multicolor flow cytometry panel. Fluorescent dye interactions may cause staining artifacts which may affect data interpretation. The BD Horizon Brilliant™ Stain Buffer was designed to minimize these interactions. When BD Horizon Brilliant™ Stain Buffer is used in in the multicolor panel, it should also be used in the corresponding compensation controls for all dyes to achieve the most accurate compensation. For the most accurate compensation, compensation controls created with either cells or beads should be exposed to BD Horizon Brilliant™ Stain Buffer for the same length of time as the corresponding multicolor panel. More information can be found in the Technical Data Sheet of the BD Horizon Brilliant™ Stain Buffer (Cat. No. 563794/566349) or the BD Horizon Brilliant™ Stain Buffer Plus (Cat. No. 566385).

.

Product Notices

  1. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  2. This reagent has been pre-diluted for use at the recommended Volume per Test. We typically use 1 × 10^6 cells in a 100-µl experimental sample (a test).
  3. An isotype control should be used at the same concentration as the antibody of interest.
  4. Please observe the following precautions: We recommend that special precautions be taken (such as wrapping vials, tubes, or racks in aluminum foil) to protect exposure of conjugated reagents, including cells stained with those reagents, to any room illumination. Absorption of visible light can significantly affect the emission spectra and quantum yield of tandem fluorochrome conjugates.
  5. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  6. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  7. Although every effort is made to minimize the lot-to-lot variation in the efficiency of the fluorochrome energy transfer, differences in the residual emission from BD Horizon™ BV421 may be observed. Therefore, we recommend that individual compensation controls be performed for every BD Horizon™ BV605 conjugate.
  8. Human donor specific background has been observed in relation to the presence of anti-polyethylene glycol (PEG) antibodies, developed as a result of certain vaccines containing PEG, including some COVID-19 vaccines. We recommend use of BD Horizon Brilliant™ Stain Buffer in your experiments to help mitigate potential background. For more information visit https://www.bdbiosciences.com/en-us/support/product-notices.
  9. Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
  10. CF™ is a trademark of Biotium, Inc.
  11. For U.S. patents that may apply, see bd.com/patents.
567963 Rev. 2
Antibody Details
Down Arrow Up Arrow
7C3.rMAb

The 7C3.rMAb is a recombinant monoclonal antibody that specifically recognizes human CD15 which is a terminal carbohydrate epitope, 3-fucosyl-N-acetyllactosamine (3-FAL), on cell surface glycoproteins or glycolipids. CD15 is also known as Lewis X (LeX), X-Hapten, or Stage-Specific Embryonic Antigen-1 (SSEA-1). The 7C3.rMAb was derived from the 7C3 (also known as, PMN7C3) hybridoma. The 7C3 antibody was validated at HLDA V (Workshop Number MA88). The 7C3.rMAb has the same IgV-region heavy chain domain and Ig, κ light chain as the original mouse 7C3 IgG3, κ antibody. The remaining Ig constant heavy chain of 7C3.rMAb is derived from the mouse IgG1 heavy chain. CD15 is expressed on a variety of cell types including neutrophils, eosinophils, monocytes, macrophages, mast cells, and Langerhans cells. CD15 is also expressed on some epithelial cells, activated lymphocytes as well as tumor cells. CD15 is not expressed by platelets or erythrocytes. CD15 plays various roles in mediating cellular adhesion, activation, migration, and phagocytosis.

567963 Rev. 2
Format Details
Down Arrow Up Arrow
BV605
The BD Horizon Brilliant Violet™ 605 (BV605) dye is part of the BD Horizon Brilliant Violet™ family of dyes. This tandem fluorochrome is comprised of a BV421 donor with an excitation maximum (Ex Max) of 407-nm and an acceptor dye with an emission maximum (Em Max) at 605-nm. BV605, driven by BD innovation, is designed to be excited by the violet laser (405-nm) and detected using an optical filter centered near 610-nm (e.g., a 610/20-nm bandpass filter). The acceptor dye can be excited by the yellow-green (561-nm) laser resulting in cross-laser excitation and fluorescence spillover. Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
altImg
BV605
Violet 405 nm
407 nm
605 nm
567963 Rev.2
Citations & References
Down Arrow Up Arrow

Development References (7)

  1. Ball ED, Persichetti J, Roscoe R, Nimgaonkar M, Winkelstein A. Expression of CD15 on CD34+ cells of the bone marrow, peripheral blood, and umbilical cord blood. In: Schlossman SF. Stuart F. Schlossman .. et al., ed. Leucocyte typing V : white cell differentiation antigens : proceedings of the fifth international workshop and conference held in Boston, USA, 3-7 November, 1993. Oxford: Oxford University Press; 1995:795-798.
  2. Ball ED. CD15 cluster workshop report. In: Schlossman SF. Stuart F. Schlossman .. et al., ed. Leucocyte typing V : white cell differentiation antigens : proceedings of the fifth international workshop and conference held in Boston, USA, 3-7 November, 1993. Oxford: Oxford University Press; 1995:790-794.
  3. Larsen GR, Sako D, Ahern TJ, et al. P-selectin and E-selectin. Distinct but overlapping leukocyte ligand specificities.. J Biol Chem. 1992; 267(16):11104-10. (Clone-specific: Cell separation). View Reference
  4. Masat T, Feliu E, Villamor N, et al. Immunophenotypic and ultrastructural study in peripheral blood neutrophil granulocytes following bone marrow transplantation.. Br J Haematol. 1997; 98(2):299-307. (Clone-specific: Flow cytometry). View Reference
  5. Nauseef WM, Root RK, Newman SL, Malech HL. Inhibition of zymosan activation of human neutrophil oxidative metabolism by a mouse monoclonal antibody.. Blood. 1983; 62(3):635-44. (Immunogen: Functional assay, Inhibition). View Reference
  6. Phillips ML, Schwartz BR, Etzioni A, et al. Neutrophil adhesion in leukocyte adhesion deficiency syndrome type 2.. J Clin Invest. 1995; 96(6):2898-906. (Clone-specific: Flow cytometry). View Reference
  7. Sedlak J, Chorvath B, Hunakova L, Bizik J, Karpatova M, Duraj J. CD15 (Lewisx) antigen: expression on non-hemopoietic cell lines and modulation on retinois-acid-induced HL-60 cells (analysedwith CD15 Panel mAb). In: Schlossman SF. Stuart F. Schlossman .. et al., ed. Leucocyte typing V : white cell differentiation antigens : proceedings of the fifth international workshop and conference held in Boston, USA, 3-7 November, 1993. Oxford: Oxford University Press; 1995:798-800.
View All (7) View Less
567963 Rev. 2

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.