Skip to main content Skip to navigation
BB515 Rat Anti-Mouse TER-119/Erythroid Cells
BB515 Rat Anti-Mouse TER-119/Erythroid Cells
Two-color flow cytometric analysis of TER-119/Erythroid Cells expressed on mouse bone marrow cells - Staining comparisons between BD Horizon™ BB515- and FITC-conjugated antibodies. Mouse bone marrow cells were preincubated with Purified Rat Anti-Mouse CD16/CD32 (Mouse BD Fc Block™) antibody (Cat. No. 553141/553142). The cells were then stained with PE Rat Anti-Mouse CD45 antibody (Cat. No. 553081/561087) and either BD Horizon™ BB515 Rat IgG2b, κ Isotype Control (Cat. No. 564421; Left Panel), BD Horizon BB515 Rat Anti-Mouse TER-119/Erythroid Cells antibody (Cat. No. 564760; Middle Panel), or FITC Rat Anti-Mouse TER-119/Erythroid Cells antibody (Cat. No. 557915/561032; Right Panel). Two-color flow cytometric dot plots showing the correlated expression of CD45 versus TER-119/Erythroid Cells (or Ig Isotype control staining) were derived from gated events with the light scattering characteristics of viable bone marrow cells. Flow cytometric analysis was performed using a BD™ LSR II Flow Cytometry System.
Two-color flow cytometric analysis of TER-119/Erythroid Cells expressed on mouse bone marrow cells - Staining comparisons between BD Horizon™ BB515- and FITC-conjugated antibodies. Mouse bone marrow cells were preincubated with Purified Rat Anti-Mouse CD16/CD32 (Mouse BD Fc Block™) antibody (Cat. No. 553141/553142). The cells were then stained with PE Rat Anti-Mouse CD45 antibody (Cat. No. 553081/561087) and either BD Horizon™ BB515 Rat IgG2b, κ Isotype Control (Cat. No. 564421; Left Panel), BD Horizon BB515 Rat Anti-Mouse TER-119/Erythroid Cells antibody (Cat. No. 564760; Middle Panel), or FITC Rat Anti-Mouse TER-119/Erythroid Cells antibody (Cat. No. 557915/561032; Right Panel). Two-color flow cytometric dot plots showing the correlated expression of CD45 versus TER-119/Erythroid Cells (or Ig Isotype control staining) were derived from gated events with the light scattering characteristics of viable bone marrow cells. Flow cytometric analysis was performed using a BD™ LSR II Flow Cytometry System.
Product Details
Down Arrow Up Arrow


BD Horizon™
Lymphocyte antigen 76; Ly76; Ly-76; TER-119; Ter119
Mouse (QC Testing)
Rat WI, also known as Wistar (outbred) IgG2b, κ
Mouse Fetal Liver
Flow cytometry (Routinely Tested)
0.2 mg/ml
104231
AB_2738934
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


Preparation And Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated with BD Horizon™ BB515 under optimum conditions and unconjugated antibody was removed.

Recommended Assay Procedures

BD™ CompBeads can be used as surrogates to assess fluorescence spillover (Compensation).  When fluorochrome conjugated antibodies are bound to CompBeads, they have spectral properties very similar to cells.   However, for some fluorochromes there can be small differences in spectral emissions compared to cells, resulting in spillover values that differ when compared to biological controls.  It is strongly recommended that when using a reagent for the first time, users compare the spillover on cells and CompBead to ensure that BD Comp beads are appropriate for your specific cellular application.

For optimal and reproducible results, BD Horizon Brilliant Stain Buffer should be used anytime two or more BD Horizon Brilliant dyes are used in the same experiment.  Fluorescent dye interactions may cause staining artifacts which may affect data interpretation.  The BD Horizon Brilliant Stain Buffer was designed to minimize these interactions.  More information can be found in the Technical Data Sheet of the BD Horizon Brilliant Stain Buffer (Cat. No. 563794/566349) or the BD Horizon Brilliant Stain Buffer Plus (Cat. No. 566385).

For optimal results, it is recommended to perform 2 washes after staining with antibodies. Cells may be prepared, stained with antibodies and washed twice with wash buffer per established protocols for immunofluorescence staining, prior to acquisition on a flow cytometer. Performing fewer than the recommended wash steps may lead to increased spread of the negative population.

Product Notices

  1. Since applications vary, each investigator should titrate the reagent to obtain optimal results.
  2. An isotype control should be used at the same concentration as the antibody of interest.
  3. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  4. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  5. Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
  6. BD Horizon Brilliant Stain Buffer is covered by one or more of the following US patents: 8,110,673; 8,158,444; 8,575,303; 8,354,239.
  7. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
564760 Rev. 2
Antibody Details
Down Arrow Up Arrow
TER-119

The TER-119 antibody specifically binds to a 52 kDa molecule associated with glycophorin A on cells of the erythroid lineage in embryonic yolk sac, fetal liver, newborn liver, adult bone marrow, adult peripheral blood, and adult lymphoid organs. The TER-119 antigen is expressed on erythroid cells from pro-erythroblast through mature erythrocyte stages, but not on cells with BFU-E or CFU-E activities. The TER-119 epitope is not detected on hematopoietic stem cells, lymphoid cells, myeloid cells, or erythroleukemia lines. The TER-119 mAb is a component of the "lineage cocktail" used in studies of hematopoietic progenitors to detect, or deplete cells committed to the hematopoietic lineages.

The antibody was conjugated to BD Horizon BB515 which is part of the BD Horizon Brilliant™ Blue family of dyes. With an Ex Max near 490 nm and an Em Max near 515 nm, BD Horizon BB515 can be excited by the blue laser (488 nm) laser and detected with a 530/30 nm filter. This dye has been exclusively developed by BD Biosciences and is up to seven times brighter than FITC with less spillover into the PE channel. Due to similar excitation and emission properties, BB515, FITC, and Alexa Fluor® 488 cannot be used simultaneously. It is not recommended to use BB515 in cocktails that include Streptavidin conjugates as it may cause high background.

564760 Rev. 2
Format Details
Down Arrow Up Arrow
BB515
The BD Horizon Brilliant™ Blue 515 (BB515) dye is part of the BD Horizon Brilliant™ Blue family of dyes. This dye is a polymer fluorochrome with an excitation maximum (Ex Max) at 490-nm and an emission maximum (Em Max) of 515-nm. Driven by BD innovation, BB515 is designed to be excited by the blue laser (488-nm) and detected using an optical filter centered near 520-nm (e.g., 530/30-nm). BB515 reagents are significantly brighter than equivalent FITC or Alexa Fluor™ 488 reagents with less spillover into the PE detector. Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
altImg
BB515
Blue 488 nm
490 nm
515 nm
564760 Rev.2
Citations & References
Down Arrow Up Arrow

Development References (5)

  1. Ikuta K, Kina T, MacNeil I, et al. A developmental switch in thymic lymphocyte maturation potential occurs at the level of hematopoietic stem cells. Cell. 1990; 62(5):863-874. (Clone-specific). View Reference
  2. Kina T, Ikuta K, Takayama E, et al. The monoclonal antibody TER-119 recognizes a molecule associated with glycophorin A and specifically marks the late stages of murine erythroid lineage. Br J Haematol. 2000; 109(2):280-287. (Immunogen: Immunoprecipitation, Western blot). View Reference
  3. Kitajima K, Kojima M, Nakajima K, et al. Definitive but not primitive hematopoiesis is impaired in jumonji mutant mice. Blood. 1999; 93(1):87-95. (Clone-specific: Flow cytometry, Immunohistochemistry). View Reference
  4. Maraskovsky E, Brasel K, Teepe M, et al. Dramatic increase in the numbers of functionally mature dendritic cells in Flt3 ligand-treated mice: multiple dendritic cell subpopulations identified. J Exp Med. 1996; 184(5):1953-1962. (Clone-specific: Cell separation, Cytotoxicity, Depletion, Flow cytometry). View Reference
  5. Osawa M, Tokumoto Y, Nakauchi H. Hematopoietic stem cells. In: Herzenberg LA, Weir DM, Blackwell C, ed. Weir's Handbook of Experimental Immunology, 5th Edition. Cambridge: Blackwell Science; 1996:66.1-66.5.
View All (5) View Less
564760 Rev. 2

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.