Congratulations! We’ve made it to the end of the Fluorochrome Faceoff games. Throughout this competition, we have highlighted some key fluorochrome characteristics that should be considered when selecting fluorochromes for flow cytometry panels.

 

As you can see, not all fluorochromes are created equal. Some are bright, some are dim; some are excited by many lasers, some are excited by only one or two; some work well for intracellular staining, some do not; and so on. For example, the StarBright Dyes are generally bright with unique spectral profiles but are not available on intracellular markers. The NovaFluor Dyes generally have clean spillover profiles but tend to be dimmer and have nonspecific background staining. PE and PerCP tandem dyes have cross laser excitation that limits their utility in higher parameter flow cytometry panels. In comparison, the BD Horizon RealYellow and BD Horizon RealBlue Dyes generally perform well across all categories measured in this competition. In the chart below, we have summarized the overall performance of the various families of dyes that competed in this Fluorochrome Faceoff.

 

 

Fluorochrome Family Summary

 

To view the games, click on the links in the first row of the table below

 

Dye FamilySpilloverResolution Buffer Compatibility Intracellular Staining Photostability Monocyte Background
What Good Looks Like:1–2 Peak/s3–4 Relative BrightnessPerm III; >50% MFI Compared to Control after TreatmentCatalog Availability<25% MFI Loss vs Time 0No Nonspecific Binding
BD Horizon RealYellow™ and RealBlue™ Reagents      
StarBright™ Blue and Yellow Reagents      
NovaFluor™ Blue and Yellow Reagents      
BD Horizon Brilliant™ Blue Reagents      
PE and PE Tandems      
PerCP and PerCP Tandems      

 

 Most dyes pass
 Some dyes pass
 Most dyes fail
 No clones available for testing
Note: Additional data supporting the generation of this chart are not shown as part of the Fluorochrome Faceoff games.

 

 

Try the Winning Fluorochromes


 

 

*Required fields

To Explore the Games, Click on the Icons Below

 

 

Competitors

 

RB780   |   PerCP/Fire™ 780 
PE-Cy7   |   cFBYG781

 

Competitors

 

RB705   |   PerCP-Cy5.5 
SBB700   |   PerCP-eFluor™ 710
BB700   |   NFB690

 

Competitors

 

RY703   |   SBY720 
NFY700

 

Competitors

 

RB613   |   PE-CF594 
PE/Dazzle™ 594

 

Competitors

 

RY610   |   PE-CF594   |   SBY605 
NF610   |   PE-eFluor™ 610

 

Competitors

 

RY775   |   PE-Cy7   |   SBY800 
PE/Fire™ 810