Skip to main content Skip to navigation
PE Mouse Anti-Human CD20
PE Mouse Anti-Human CD20
Flow cytometric analysis of CD20 (cytoplasmic domain) expressed by human peripheral blood lymphocytes. Human whole blood was treated with BD Phosflow™ Lyse/Fix Buffer (Cat. No. 558049) for 10 min at 37°C to lyse erythrocytes and fix the leukocytes in one step. The leukocytes were permeabilized with BD Phosflow™ Perm Buffer I (Cat. No. 557885) for 20 minutes. The cells were then stained with either PE Mouse IgG2a, κ Isotype Control MOPC-173 (Cat. No. 558595; dashed line histogram) or PE Mouse anti-human CD20 (cytoplasmic) antibody (Cat. No. 561174; solid line histogram). The fluorescence histograms were derived from gated events with the forward and side light-scatter characteristics of lymphocytes. Flow cytometry was performed using a BD™ LSR II Flow Cytometer System.
Flow cytometric analysis of CD20 (cytoplasmic domain) expressed by human peripheral blood lymphocytes. Human whole blood was treated with BD Phosflow™ Lyse/Fix Buffer (Cat. No. 558049) for 10 min at 37°C to lyse erythrocytes and fix the leukocytes in one step. The leukocytes were permeabilized with BD Phosflow™ Perm Buffer I (Cat. No. 557885) for 20 minutes. The cells were then stained with either PE Mouse IgG2a, κ Isotype Control MOPC-173 (Cat. No. 558595; dashed line histogram) or PE Mouse anti-human CD20 (cytoplasmic) antibody (Cat. No. 561174; solid line histogram). The fluorescence histograms were derived from gated events with the forward and side light-scatter characteristics of lymphocytes. Flow cytometry was performed using a BD™ LSR II Flow Cytometer System.
Product Details
Down Arrow Up Arrow


BD Phosflow™
MS4A1; membrane-spanning 4-domains subfamily A member 1; B1; Bp35; LEU-16
Human (QC Testing)
Mouse BALB/c IgG2a, κ
Human B lymphoma cell line
Intracellular staining (flow cytometry) (Routinely Tested)
5 µl
V cB010
AB_10563904
Aqueous buffered solution containing BSA and ≤0.09% sodium azide.
RUO


Preparation And Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated with R-PE under optimum conditions, and unconjugated antibody and free PE were removed.

Product Notices

  1. This reagent has been pre-diluted for use at the recommended Volume per Test. We typically use 1 × 10^6 cells in a 100-µl experimental sample (a test).
  2. An isotype control should be used at the same concentration as the antibody of interest.
  3. Source of all serum proteins is from USDA inspected abattoirs located in the United States.
  4. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  5. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  6. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
561174 Rev. 2
Antibody Details
Down Arrow Up Arrow
H1

The H1 (FB1) antibody specificially binds to a cytoplasmic domain of CD20. CD20 is a 33-37-kDa four transmembrane phosphoprotein that is expressed by B lymphocytes from the pre-B stage and most malignant B cells and is lost during plasma cell differentiation.  Low level CD20 expression is observed on a subset of normal circulating T lymphocytes, and CD20-positive T-cell lymphomas have been reported.  The CD20 molecule is associated with membrane lipid raft domains, acts as a channel for calcium ions, and is involved in the regulation of B cell activation and survival.  The cytoplasmic domain regions are serine and threonine rich and contain multiple phosphorylation consensus sequences.

561174 Rev. 2
Format Details
Down Arrow Up Arrow
PE
R-Phycoerythrin (PE), is part of the BD family of Phycobiliprotein dyes. This fluorochrome is a multimeric fluorescent phycobiliprotein with excitation maximum (Ex Max) of 496 nm and 566 nm and an emission maximum (Em Max) at 576 nm. PE is designed to be excited by the Blue (488 nm), Green (532 nm) and Yellow-Green (561 nm) lasers and detected using an optical filter centered near 575 nm (e.g., a 575/26-nm bandpass filter). As PE is excited by multiple lasers, this can result in cross-laser excitation and fluorescence spillover on instruments with various combinations of Blue, Green, and Yellow-Green lasers. Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
altImg
PE
Yellow-Green 488 nm, 532 nm, 561 nm
496 nm, 566 nm
576 nm
561174 Rev.2
Citations & References
Down Arrow Up Arrow
View product citations for antibody "561174" on CiteAb

Development References (4)

  1. Cragg MS, Walshe CA, Ivanov AO, Glennie MJ. The biology of CD20 and its potential as a target for mAb therapy. Curr Dir Autoimmun. 2005; 8:140-174. (Biology). View Reference
  2. Kitamura A, Yamashita Y, Mori N. CD20-positive cytotoxic T cell lymphoma: report of two cases and review of the literature. J Clin Exp Hematop. 2005; 45(1):45-50. (Biology).
  3. Nozawa Y, Abe M, Ohno H, Fukuhara S, Wakasa H. Production of two monoclonal antibodies (FB1 and FB21) useful for the identification of human B lymphocytes in formalin-fixed, paraffin-embedded tissues. J Pathol. 1994; 173:347-354. (Immunogen). View Reference
  4. Nozawa Y, Abe M, Wakasa H. Three mAb, FUN-1, FB1, and FB21, that recognize B-cell antigens in frozen or paraffin-embedded tissue sections. In: Schlossman SF. Stuart F. Schlossman .. et al., ed. Leucocyte typing V : white cell differentiation antigens : proceedings of the fifth international workshop and conference held in Boston, USA, 3-7 November, 1993. Oxford: Oxford University Press; 1995:705-706.
View All (4) View Less
561174 Rev. 2

 

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.