Skip to main content Skip to navigation

BD Horizon RealViolet™ 544 Reagents

View Products

A Moderately Bright Fluorochrome with Narrow Emission off the Violet Laser

 

BD Horizon RealViolet™ 544 (RV544) Reagents leverage an innovative laser-specific fluorochrome, excited primarily by the 405-nm violet laser to offer:

 

  • Narrow emission off the violet laser
  • Moderate brightness to support the detection of medium- to high-expression surface and intracellular markers
  • Compatibility with neighboring BD Horizon Brilliant Violet™ Fluorochromes, enabling use in high parameter spectral panels
 
RV544 vials
performance1

RV544 Reagents Can Be Used with Moderate- to High-Density Antigens on Spectral Flow Cytometers

RV544 specifications

 

FormatEx MaxEm MaxSpectralConventionalRelative BrightnessSpillover* (1 = low, 4 = high)Alternative To
RV544412 nm546 nm✓- 2Spark™ V538, StarBright™ Violet 535,
Pacific Orange, Amethyst Orange,
cFluor™  V547, Krome Orange
*Value may vary based on instrument configuration and settings. Spillover ranking is based on cross-laser excitation on five-laser spectral instruments and does not take into account spillover into adjacent detectors.

 

View Products

 

 

Performance

BD Horizon RealViolet™ 544 Reagents Provide Narrow Emission Off the 405-nm Violet Laser and Reduced Cross-laser Excitation Off the 355-nm UV Laser

 
RV544 has narrow emission off the violet laser and reduced UV-cross-laser excitation
RV544 narrow emission off the violet laser

Normalized emission profiles of RV544, Spark Violet™ 538 (Spark V538) and Pacific Orange. PBMCs stained with human CD4 SK3 antibody (RV544 and Spark V538) or human CD4 RPA-T4 (Pacific Orange) and acquired on a BD FACSDiscover™ S8 Cell Sorter.

RV544 works well with neighboring BD Horizon Brilliant Violet™ Fluorochromes  
RV544 works well with neighboring BD Horizon Brilliant Violet™ Fluorochromes

Spectral signature heat map of RV544 (pink) with all BD Horizon Brilliant™ Violet Fluorochromes and BD Horizon RealViolet™ 828 (RV828) Fluorochrome. PBMCs stained with human CD4 SK3 antibody and acquired on a BD FACSDiscover™ S8 Cell Sorter.

 

View Products

Applications

Multicolor Flow Cytometry

BD Horizon™ RV544 works well for spectral flow cytometry panels 

 

RV544 works well with neighboring fluorochromes on a spectral cell sorter 
RV544 works well with neighboring Fluorochromes

Similarity index values from the BD FACSDiscover™ S8 Cell Sorter. RV544 is compatible with existing neighboring and cross-laser dyes.

RV544 works well in a 31-color spectral human immunophenotyping BD FACSDiscover™ A8 Cell Analyzer panel

RV544 31-Color Human Immunophenotyping Panel

Human peripheral blood mononuclear cells were stained with a viability dye and antibodies against cell surface markers. BD Horizon™ Brilliant Stain Buffer Plus was used to mitigate dye-dye interactions. Cells were analyzed on a BD FACSDiscover™ A8 Cell Analyzer and data were analyzed with FlowJo™ Software v10.10. A gating strategy for immunophenotyping, including detection of dendritic cells, monocytes, B cells, NK cell subsets and T cell subsets, after exclusion of dead cells and doublets, is shown.​

Fluorochrome marker assignment for a 31-color human immune monitoring panel

 

 SpecificityCloneFluorochrome
UV 349 nmCD45RAHI100BUV395
CD8RPA-T8BUV496
CD38HIT2BUV615
CD19HIB19BUV661
TCR γδ11F2BUV737
CD185 (CXCR5)RF8B2BUV805
Violet
405 nm

CD45

HI30

V450

CD197 (CCR7)

2-L1-A

BV421

CD14

M5E2

BV480

CD3

UCHT1

RV544

Viability

N/A

FVS575V
CD24ML4BV786
CD11cB-Ly6RV828
Blue
488 nm

CD57

NK-1

FITC

CD20

2H7

RB545

CD16

3G8

RB575

CD25

2A3

RB613
CX3CR12A9-1RB670
CD279 (PD-1)EH12.1RB705
CD127 (IL-7Rα)HIL-7R-M21RB744
CD28CD28.2RB780
CD4SK3RB824
Yellow-Green
561 nm

KLRG1

Z7-205.rMAb

RY586

CD56

B159

RY610

CD95 (Fas)

DX2

RY655
CD366 (TIM-3)7D3RY703
CD272 (BTLA)J168-540RY743
CD27M-T271RY775
Red 637 nmCD161DX12RR688
TIGITTgMab-2R718
HLA-DRG46-6APC-H7
 

View Products

 

Buffer Compatibility

BD Horizon™ RV544 Reagents Are Compatible with a Broad Range of Fixation and Permeabilization Systems

 

BuffersResults
BD FACS™ Lysing Solution and BD Pharm Lyse™ Lysing BufferCompatible
CellBlox™ Blocking BufferCompatible
BD Cytofix™ Fixation BufferStable at least 24 hours
1% PFAStable at least 24 hours
BD Cytofix/Cytoperm™ Fixation and Permeabilization SolutionCompatible with antibody staining before and after fixation
BD FACS™ Permeabilizing Solution 2Compatible with antibody staining before and after fixation
BD Phosflow™ Perm Buffer IIICompatible with antibody staining before and after fixation
EDTA and HeparinCompatible
BD Horizon™ Brilliant Stain Buffer (BSB)Compatible
 

  

BD flow cytometers are Class 1 Laser Products.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.

CF is a trademark of Biotium, Inc. Cy is a trademark of Global Life Sciences Solutions Germany GmbH or an affiliate doing business as Cytiva. CellBlox is a trademark of Thermo Fisher Scientific.