Skip to main content Skip to navigation

BD FACSLyric™ Clinical Flow Cytometry System

Discover how this flow cytometer can transform your clinical lab with outstanding performance, automation and standardization

 

 

For Professionals in Clinical Diagnostics

 

Discover the BD FACSLyric™ Flow Cytometry System difference

  • Witness clinical performance results you have never seen before through high sensitivity and improved resolution
  • Streamline your lab workflow through flexibility and automation, enabling efficiency and productivity
  • Achieve automated standardization through highly reproducible results and enable collaboration through assay portability
  • See how the BD FACSLyric™ System can transform your lab

 

Get more information from the BD FACSLyric™ Flow Cytometry System Brochure

 
performance1

Features

Discover the BD FACSLyric™ Flow Cytometry System—A Next-Generation Flow Cytometer

Built on a foundation of excellence, experience and expertise, the BD FACSLyric™ Flow Cytometry System is our next generation diagnostic standard for clinical cell analysis, transforming the way your lab does flow cytometry. As with all BD instruments, the BD FACSLyric™ Flow Cytometry System is backed by 40 years of BD expert training, service and support—so there’s no limit to your potential.

The Power of the BD FACSLyric™ Flow Cytometer

 

  • 4-, 6-, 8-, 10- and 12-color configurations. Onsite upgradeable to adapt to your lab's changing needs
  • Up to 3 lasers—blue, red and violet—12 fluorescence channels and 14 parameters
  • 35,000 events per second maximum acquisition rate; no limit on number of events acquired
  • Automated single-tube QC with BD® CS&T Beads
  • Fluorescence compensation required only every 60 days, improving efficiency and productivity
  • 21 different loading options: plates or tubes; built-in flexibility with BD FACS™ Universal Loader
  • Powered by BD FACSuite™ Clinical Software for Acquisition and Analysis, supports U.S, FDA 21 CFR Part 11 compliance offering password protection, audit trail, electronic signatures and IQ/OQ procedures
  • BD FACSLink™ Laboratory Information System (LIS) Interface and BD Assurity Linc™ Remote Systems Management Software streamline your workflow and help improve productivity through seamless integration.

 

See how you can simplify your workflow using the automated instrument setup and compensation on the BD FACSLyric™ System.

 
performance1

Performance

A new diagnostic standard delivering outstanding performance and standardization within and between instruments

The BD FACSLyric™ Flow Cytometry System is a high-performance, highly sensitive flow cytometer that demonstrates exceptional resolution and improved separation to make dim and rare cell populations easier to resolve.

 

 

 

Highly reproducible results between instruments drive standardization

 

BD FACSLyric™ System Variance (CVs)
15 BD FACSLyric™ Systems: Lyse/Wash settings and BD FC® Beads
Blue Laser %CV
FITC 4.2
PE 4.4
PE-Cy7 4.8
PerCP 10.2
PerCP-Cy5.5 7.9
Red Laser %CV
APC 5.3
APC-Cy7 4.1
APC-H7 3.9
APC-R700 4.2
   
Violet Laser %CV
BD Horizon™ V450 11.1
BD Horizon™ V500 11
BD Horizon™ BV605 13.6
BD Horizon™ BV711 7.5
BD Horizon™ BV786 15.3

 

Between-instrument reproducibility of target MFI values on the BD FACSLyric™ System

Lyse/wash assay settings were imported across 15 instruments to show effects of standardization on beads. The CVs of the fluorescence intensity across all channels varies by less than 15.3%. Daily QC with one lot of BD® Cytometer Setup & Tracking Beads was run on fifteen BD FACSLyric™ Flow Cytometers. For each instrument, the PMTV gains were automatically adjusted to meet the target values. BD® FC Beads acquired on each BD FACSLyric™ Instrument. The MFI of positive populations was measured for all parameters across all instruments. The %CV is shown. The data for this internal study were acquired using BD® FC Beads across 15 BD FACSLyric™ Instruments. Greater between-instrument variability could be observed when running biological samples, when using non BD reagents or when comparing fewer instruments. 

Applications

A Powerful Solution for CD4 Counts and Other Immunological Assessment

With the BD FACSLyric™ Flow Cytometer, clinical laboratories can obtain repeatable and reliable results for immunological assessment of patients having or suspected of having an immune deficiency such as HIV.

BD FACSLyric™ Clinical Flow Cytometry System

Discover how this flow cytometer can transform your clinical lab with outstanding performance, automation and standardization 

Request Quote
performance1
Journal Publication

Omana-Zapata I, Mutschmann C, Schmitz J, et al. Accurate and reproducible enumeration of T-, B- and NK lymphocytes using the BD FACSLyric 10-Color System: a multisite clinical evaluation. PLoS One. 2019;14(1):e0211207. doi: 10.1371/journal.pone.0211207. 

performance1

Class 1 Laser Product  Cy™ is a trademark of GE Healthcare.

Cy™ dyes are subject to proprietary rights of GE Healthcare and Carnegie Mellon University, and are made and sold under license from GE Healthcare only for research and in vitro diagnostic use.

Any other use requires a commercial sublicense from GE Healthcare, 800 Centennial Avenue, Piscataway, NJ 08855-1327, USA. The BD FACSLyric™ Flow Cytometer is for In Vitro Diagnostic Use with BD FACSuite™ Clinical Application for up to 6 colors. 7 to 12 colors are for Research Use Only.

BD FACSuite™ Clinical Application is for In Vitro Diagnostic Use. BD FACSuite™ Application is for some IVD, ASR and RUO products only.

Refer to manufacturer's instructions for use and related User Manuals and Technical Data Sheets before using this product as described.

Comparisons, where applicable, are made against older BD technology, manual methods or are general performance claims. Comparisons are not made against non-BD technologies, unless otherwise noted.