Skip to main content Skip to navigation

Overview

The BD OneFlow™ B-CLPD T1 is part of the innovative BD OneFlow™ Solution, a comprehensive set of reagents, setup beads, protocols and assay templates to reproducibly set up the flow cytometer and stain, acquire and analyze patient specimens for immunophenotyping of normal and aberrant cell populations. It is built on the research and validation work of the EuroFlow™ Consortium on the characterization of hematological malignancies for improved accurate diagnosis.1*

 

The BD OneFlow™ B-CLPD T1 is intended for flow cytometric immunophenotyping of B cells in peripheral blood and bone marrow.

 

Other reagents belonging to the BD OneFlow™ Solution are BD OneFlow™ LSTBD OneFlow™ ALOTBD OneFlow™ PCST, and BD OneFlow™ PCD.

performance1

FEATURES

The BD OneFlow™ B-CLPD T1 reagent composition

 

AntibodyFluorochromeCloneTarget Populations
CD23FITCEBVCS-5Contributes to the classification of CLL or other B-cell chronic lymphoproliferative diseases

CD10

PEMEM-78Contributes to the classification of CLL or other B-cell chronic lymphoproliferative diseases
CD79bPerCP-Cy 5.5SN8Contributes to the classification of CLL or other B-cell chronic lymphoproliferative diseases
CD19PE-CY 7 SJ25-C1Backbone marker. In common with BD OneFlow™ LST
CD200APCMRC 0X-104Contributes to the classification of CLL or other B-cell chronic lymphoproliferative diseases
CD43APC-H71G10Contributes to the classification of CLL or other B-cell chronic lymphoproliferative diseases
CD20BD Horizon™ V450L27Backbone marker. In common with BD OneFlow™ LST
CD45BD Horizon™ V500-C2D1Backbone marker. In common with BD OneFlow™ LST

 

The EuroFlow antibody panel article1* has a full description of the utility of the antibodies chosen for the BD OneFlow™ B-CLPD T1.

 

 

APPLICATIONS

References

  1. van Dongen JJM, Lhermitte L, Böttcher S, et al. on behalf of the EuroFlow Consortium (EU-FP6, LSHB-CT-2006-018708). EuroFlow antibody panels for standardized n-dimensional flow cytometric immunophenotyping of normal, reactive and malignant leukocytes. Leukemia. 2012;26(9): 1908-1975. doi: 10.1038/leu.2012.120

  2. Moloney E, Watson H, Barge D, et al. Efficiency and health economic evaluations of BD OneFlow™ Flow Cytometry Reagents for diagnosing chronic lymphoid leukemia. Cytometry B Clin Cytom. 2019;96(6):514-520. doi: 10.1002/cyto.b.21779

  3. Kalina T, Flores-Montero J, van der Velden VHJ, et al. EuroFlow standardization of flow cytometer instrument settings and immunophenotyping protocols. Leukemia. 2012;26(9):1986-2010. doi: 10.1038/leu.2012.122
For Research Use Only. Not for use in diagnostic or therapeutic procedures.