RB780 Mouse Anti-Human uPA (PLAU)

BD OptiBuild™ RB780 Mouse Anti-Human uPA (PLAU)

Clone UK98/6 (also known as UK 98/6; 98/6)

(RUO)
Product Details
Down Arrow Up Arrow


BD OptiBuild™
ATF; PLAU; U-plasminogen activator; UPA; u-PA; urokinase-type plasminogen activator
Human (Tested in Development)
Mouse BALB/c IgG1, κ
Purified Human Urokinase-type Plasminogen Activator
Flow cytometry (Qualified)
0.2 mg/ml
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


Preparation And Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated to the dye under optimum conditions that minimize unconjugated dye and antibody.

Recommended Assay Procedures

BD® CompBeads can be used as surrogates to assess fluorescence spillover (compensation). When fluorochrome conjugated antibodies are bound to BD® CompBeads, they have spectral properties very similar to cells. However, for some fluorochromes there can be small differences in spectral emissions compared to cells, resulting in spillover values that differ when compared to biological controls. It is strongly recommended that when using a reagent for the first time, users compare the spillover on cells and BD® CompBeads to ensure that BD® CompBeads are appropriate for your specific cellular application.

Product Notices

  1. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  2. Please observe the following precautions: Absorption of visible light can significantly alter the energy transfer occurring in any tandem fluorochrome conjugate; therefore, we recommend that special precautions be taken (such as wrapping vials, tubes, or racks in aluminum foil) to prevent exposure of conjugated reagents, including cells stained with those reagents, to room illumination.
  3. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  4. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  5. An isotype control should be used at the same concentration as the antibody of interest.
  6. Since applications vary, each investigator should titrate the reagent to obtain optimal results.
  7. Human donor specific background has been observed in relation to the presence of anti-polyethylene glycol (PEG) antibodies, developed as a result of certain vaccines containing PEG, including some COVID-19 vaccines. We recommend use of BD Horizon Brilliant™ Stain Buffer in your experiments to help mitigate potential background. For more information visit https://www.bdbiosciences.com/en-us/support/product-notices.
  8. Researchers should determine the optimal concentration of this reagent for their individual applications.
  9. The production process underwent stringent testing and validation to assure that it generates a high-quality conjugate with consistent performance and specific binding activity. However, verification testing has not been performed on all conjugate lots.
756735 Rev. 1
Antibody Details
Down Arrow Up Arrow
UK98/6

The UK98/6 monoclonal antibody specifically recognizes Urokinase-type Plasminogen Activator (uPA) that is encoded by PLAU (Plasminogen Activator Urokinase). uPA (PLAU) is secreted as an inactive single-chain precursor protein (Pro-urokinase or Pro-uPA) by various cells including vascular endothelial cells, renal epithelial cells, fibroblasts, monocytes, macrophages, smooth muscle cells and tumor cells of different origin. Following proteolytic cleavage, two resulting chains are disulfide bonded together with an amino-terminal A-chain (ATF) with EGF-like growth factor and Kringle domains bound to a catalytically active peptidase, the C-terminal B-chain. uPA (PLAU) binds to cell-surface CD87 (also known as, Urokinase Plasminogen Activator Receptor or uPA-R) by its growth factor-like domain. CD87 is widely expressed by monocytes, neutrophils, dendritic cells, activated T cells, NK cells, fibroblasts, endothelial cells, keratinocytes, and some tumor cells. The cell-associated form of uPA (PLAU) efficiently acts upon the plasminogen proenzyme to generate active plasmin which degrades blood plasma proteins and dissolves fibrin blood clots. uPA (PLAU) also activates collagenases that are involved in the breakdown of the extracellular matrix as well as some mediators of the complement system. It may play a role in tumor cell proliferation, migration, and metastases. A specific polymorphism of uPA (PLAU) is associated with late-onset Alzheimer's disease. The UK98-6 antibody can reportedly suppress the biological activity of uPA (PLAU).

756735 Rev. 1
Format Details
Down Arrow Up Arrow
RB780
The BD Horizon RealBlue™ 780 (RB780) Dye is part of the BD family of blue dyes. It is a tandem fluorochrome with an excitation maximum (Ex Max) at 498-nm and an emission maximum (Em Max) at 781-nm. Driven by BD innovation, RB780 can be used on both spectral and conventional cytometers and is designed to be excited by the Blue laser (488-nm) with minimal excitation by the 561-nm Yellow-Green laser. For conventional instruments equipped with a Blue laser (488-nm), RB780 can be used as an alternative to PE-Cy7 and we recommend using an optical filter centered near 780-nm (eg, a 780/60-nm bandpass filter). For spectral instruments equipped with a Blue laser (488-nm), it can be used in conjunction with PE-Cy7. RB780 is on average brighter than PE-Cy7 and has minimal spillover into Yellow-Green detectors.
altImg
RB780
Blue 488 nm
498 nm
781 nm
756735 Rev.1
Citations & References
Down Arrow Up Arrow
View product citations for antibody "756735" on CiteAb

Development References (6)

  1. Danø K, Andreasen PA, Grøndahl-Hansen J, Kristensen P, Nielsen LS, Skriver L. Plasminogen activators, tissue degradation, and cancer.. Adv Cancer Res. 1985; 44:139-266. (Biology). View Reference
  2. Finckh U, van Hadeln K, Müller-Thomsen T, et al. Association of late-onset Alzheimer disease with a genotype of PLAU, the gene encoding urokinase-type plasminogen activator on chromosome 10q22.2.. Neurogenetics. 2003; 4(4):213-7. (Biology). View Reference
  3. Heidtmann HH, Hofmann M, Jacob E, Erbil C, Havemann K, Schwartz-Albiez R. Synthesis and secretion of plasminogen activators and plasminogen activator inhibitors in cell lines of different groups of human lung tumors.. Cancer Res. 1989; 49(24 Pt 1):6960-5. (Biology: Flow cytometry). View Reference
  4. Meissauer A, Kramer MD, Hofmann M, et al. Urokinase-type and tissue-type plasminogen activators are essential for in vitro invasion of human melanoma cells.. Exp Cell Res. 1991; 192(2):453-9. (Clone-specific: Blocking, ELISA, Functional assay). View Reference
  5. Meissauer A, Kramer MD, Schirrmacher V, Brunner G. Generation of cell surface-bound plasmin by cell-associated urokinase-type or secreted tissue-type plasminogen activator: a key event in melanoma cell invasiveness in vitro.. Exp Cell Res. 1992; 199(2):179-90. (Clone-specific: Blocking, ELISA, Functional assay). View Reference
  6. Schwartz-Albiez R, Heidtmann HH, Wolf D, Schirrmacher V, Moldenhauer G. Three types of human lung tumour cell lines can be distinguished according to surface expression of endogenous urokinase and their capacity to bind exogenous urokinase.. Br J Cancer. 1992; 65(1):51-7. (Immunogen: ELISA, Radioimmunoassay, Western blot). View Reference
View All (6) View Less
756735 Rev. 1

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.

Refer to manufacturer's instructions for use and related User Manuals and Technical Data Sheets before using this product as described.

Comparisons, where applicable, are made against older BD technology, manual methods or are general performance claims. Comparisons are not made against non-BD technologies, unless otherwise noted.