BD Horizon RealBlue™ 780 Reagents
A Bright, Clean Dye

BD Horizon RealBlue™ 780 (RB780) Reagents leverage an innovative laser-specific fluorochrome, excited primarily by the 488-nm blue laser to offer:

 

  • Minimal cross-laser excitation off the 561-nm yellow-green laser
  • A bright fluorochrome to support the detection of low-expression surface and intracellular markers
  • Reduced monocyte background compared to PE-Cy7

RB780 Reagents Can Be Used with PE-Cy7 on Appropriately Configured Conventional and Spectral Flow Cytometers

RB780 specifications

 

FormatEx MaxEm MaxSpectralConventionalRelative BrightnessSpillover* (1 = low, 4 = high)Alternative To
RB780488 nm780 nm 1PE-Cy7,
PerCP/Fire™ 780,
BB790-P
 
*Value may vary based on instrument configuration and settings. Spillover ranking is based on cross-laser excitation on five-laser spectral instruments and does not take into account spillover into adjacent detectors.
 

View Products

Performance

BD Horizon RealBlue 780 Reagents Provide Minimal Cross-laser Excitation Off the 561-nm Yellow-Green Laser and Reduced Background Compared to PE-Cy7

 
RB780 has minimal cross-laser excitation
RB780 Minimum Cross Laser Excitation

Normalized emission profiles of RB780 and PE-Cy7 fluorochromes. Human CD4 SK3 antibody acquired on a BD FACSDiscover S8 Cell Sorter.

Compared to PE-Cy7, RB780 shows lower spillover spread into detectors on the yellow-green laser
RB780 Lower Spillover

Human whole blood was stained with BD Horizon RB780 Human CD4 (SK3) Reagent, acquired and compensated on a BD FACSymphony A5 SE Cell Analyzer. The biexponential scaling was set for PE-Cy7 and applied to RB780 to highlight changes in spread into selected channels.

 

BD Horizon™ RB780 Reagents offer reduced background compared to PE-Cy7
RB780 reduced background compared to PE0Cy7

Human whole blood was stained with PE-Cy7 or BD Horizon™ RB780 conjugated to human CD3 (UCHT1) Reagent, CD4 (SK3), human CD8 (RPA-T8), or human CD19 (SJ25C1), followed by lysis with BD FACS Lysing Solution. All specificities are analyzed with the B810 detector on a BD FACSymphony A5 SE Cell Analyzer.

View Products

 

Applications

Multicolor Flow Cytometry

BD Horizon™ RB780 Reagents Resolve Well in a 12-color T Cell Inhibitory Panel Acquired on the BD FACSLyric™ Flow Cytometry System

 

Gating scheme of T cell subsets
RB780 Resolution- n-BD FACSLyric 12-Color Panel

Healthy PBMC were stained with a 12-color inhibitory T cell panel and acquired on the BD FACSLyric Flow Cytometry System. Labels on top of each plot show the parental gate from which plots are derived; numbers in each quadrant represent the frequency of cell population; T cell subsets are identified as N, naïve; CM, central memory; EM, effector memory; EMRA, effector memory RA+; and SCM, stem cell like memory.

RB780 Reagents and PE-Cy7 Can Be Used Together in Spectral Flow Cytometry

 

RB780 reagents and PE-Cy7 are used together in a multicolor panel to identify rare cell populations

RB780-PE-Cy7-Multicolor-Flow-Usage

BD Horizon RB780 Reagents and PE-Cy7 can be used together in a multicolor panel to identify rare cell populations. CD123 BD Horizon RB780 Reagent and CD303 PE-Cy7 co-expresses on a sub-population of human plasmacytoid dendritic cells (pDC). Flow plots show clear distinction of the pDC population marked as CD123+ CD303+ cells derived from lineage negative CD14-CD16-, HLA-DR+ CD11c- cell populations in healthy PBMC samples. Samples were stained with the panel reagents along with Human BD Fc Block Reagent and analyzed on a BD FACSymphony A5 SE Flow Cytometer. FlowJov10.8 Software was used for spectral unmixing and analysis.

 

View Products

Buffer Compatibility

BD Horizon RealBlue RB780 Reagents Are Compatible with a Broad Range of Fixation and Permeabilization Systems

 

BuffersResults
BD FACS™ Lysing Solution and BD Pharm Lyse™ Lysing BufferCompatible
CellBlox™ Blocking BufferCompatible
BD Cytofix™ Fixation BufferStable at least 24 hours
1% PFAStable at least 24 hours
BD Cytofix/Cytoperm™ Fixation and Permeabilization SolutionCompatible with antibody staining before and after fixation
BD FACS™ Permeabilizing Solution 2Compatible with antibody staining before and after fixation
BD Phosflow™ Perm Buffer IIICompatible with antibody staining before and after fixation
EDTA and HeparinCompatible
BD Horizon™ Brilliant Stain Buffer (BSB)Compatible
 
prev
next

“The RB780 fluorochrome fits very well into the spectral gap of dyes primarily excited by the blue laser and can be separated beautifully from PE-Cy7 on instruments with blue and yellow-green lasers.”

 

“The RB780 fluorochrome fits very well into the spectral gap of dyes primarily excited by the blue laser and can be separated beautifully from PE-Cy7 on instruments with blue and yellow-green lasers.”

 

Dr. Florian Ebner
Distinguished Lab Scientist
Cancer Pharmacology and Disease Positioning

“I’m really excited about the BD Horizon RealBlue 780 Dye. The staining we have done so far with Ki-67 and Granzyme B can be seen very clearly, even with high dilutions.”

Testimonial image 1

“I’m really excited about the BD Horizon RealBlue 780 Dye. The staining we have done so far with Ki-67 and Granzyme B can be seen very clearly, even with high dilutions.”

Johannes Brandi
Researcher
Bernhard Nocht Institute for Tropical Medicine
prev
next

   

   

BD flow cytometers are Class 1 Laser Products. For Research Use Only. Not for use in diagnostic or therapeutic procedures.

The BD FACSLyric™ Flow Cytometer is for Research Use Only with BD FACSuite™ Application for up to 12 colors. Not for use in diagnostic or therapeutic procedures.

CF is a trademark of Biotium, Inc. Cy is a trademark of Global Life Sciences Solutions Germany GmbH or an affiliate doing business as Cytiva. CellBlox is a trademark of Thermo Fisher Scientific.