BUV395 Mouse Anti-Human CD40L (CD154)
Product Details
Down Arrow Up Arrow


BD OptiBuild™
CD40 ligand; CD40-L; CD40LG; T-BAM; TNFSF5; TRAP; gp39; hCD40L
Human (Tested in Development)
Mouse BALB/c IgG1, κ
Human gp39 Protein
Flow cytometry (Qualified)
0.2 mg/ml
Aqueous buffered solution containing ≤0.09% sodium azide.
RUO


Preparation And Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated to the dye under optimum conditions that minimize unconjugated dye and antibody.

Recommended Assay Procedures

BD™ CompBeads can be used as surrogates to assess fluorescence spillover (Compensation).  When fluorochrome conjugated antibodies are bound to CompBeads, they have spectral properties very similar to cells.   However, for some fluorochromes there can be small differences in spectral emissions compared to cells, resulting in spillover values that differ when compared to biological controls.  It is strongly recommended that when using a reagent for the first time, users compare the spillover on cells and CompBead to ensure that BD Comp beads are appropriate for your specific cellular application.

For optimal and reproducible results, BD Horizon Brilliant Stain Buffer should be used anytime two or more BD Horizon Brilliant dyes are used in the same experiment.  Fluorescent dye interactions may cause staining artifacts which may affect data interpretation.  The BD Horizon Brilliant Stain Buffer was designed to minimize these interactions.  More information can be found in the Technical Data Sheet of the BD Horizon Brilliant Stain Buffer (Cat. No. 563794/566349) or the BD Horizon Brilliant Stain Buffer Plus (Cat. No. 566385).

Product Notices

  1. The production process underwent stringent testing and validation to assure that it generates a high-quality conjugate with consistent performance and specific binding activity. However, verification testing has not been performed on all conjugate lots.
  2. Researchers should determine the optimal concentration of this reagent for their individual applications.
  3. An isotype control should be used at the same concentration as the antibody of interest.
  4. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  5. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  6. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  7. BD Horizon Brilliant Stain Buffer is covered by one or more of the following US patents: 8,110,673; 8,158,444; 8,575,303; 8,354,239.
  8. Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
  9. BD Horizon Brilliant Ultraviolet 395 is covered by one or more of the following US patents: 8,158,444; 8,575,303; 8,354,239.
752852 Rev. 1
Antibody Details
Down Arrow Up Arrow
24-31

The 24-31 monoclonal antibody specifically binds to CD40 Ligand (CD40L) which is also known as CD154, gp39, T-B cell-activating molecule (T-BAM), Tumor necrosis factor ligand superfamily member 5 (TNFSF5), and TNF-related activation protein (TRAP). CD40L (CD154) is an ~39 kDa type II membrane glycoprotein that is encoded by CD40LG. It is expressed on a variety of cell types including activated CD4+ T cells and some CD8+ T cells, NK cells, mast cells and basophils. CD40L (CD154) serves as a ligand for CD40 that is expressed on B cells, macrophages, and dendritic cells.  The expression of CD40L (CD154) by activated T-helper cells costimulates B-cell activation and proliferation through binding to CD40 expressed on B cells. In response to T-dependent antigens, the CD40L (CD154) and CD40 interaction is required for B-lymphocyte differentiation, including immunoglobulin production and isotype switching and memory B cell generation. The 24-31 antibody can reportedly block T cell-B cell interaction and inhibit the subsequent proliferation, differentiation, and memory formation of B cells. It has been reported that patients with X-linked hyper-IgM syndrome have defective expression of functional CD40L (CD154) due to mutations in the CD40LG gene.

The antibody was conjugated to BD Horizon BUV395 which is part of the BD Horizon Brilliant™ Ultraviolet family of dyes. With an Ex Max near 348 nm and an Em Max near 395 nm, BD Horizon BUV395 can be excited by the ultraviolet laser (355 nm) laser and detected with a 379/28 filter. This dye has been exclusively developed by BD Biosciences as an optimal dye for use on instruments equipped with the ultraviolet laser and has virtually no spillover into any other detector.

752852 Rev. 1
Format Details
Down Arrow Up Arrow
BUV395
The BD Horizon Brilliant™ Ultraviolet 395 (BUV395) Dye is part of the BD Horizon Brilliant™ Ultraviolet family of dyes. This base dye is a polymer fluorochrome with an excitation maximum (Ex Max) of 348-nm and an emission maximum (Em Max) at 395-nm. Driven by BD innovation, BUV395 is designed to be excited by the ultraviolet laser (355-nm) and detected using an optical filter centered near 380-nm (e.g., 379/28-nm bandpass filter). BUV395 is the ideal dye when using only one detector on the ultraviolet laser as it spills into no other detectors and no other fluors spill into it. Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
altImg
BUV395
Ultraviolet 355 nm
348 nm
395 nm
752852 Rev.1
Citations & References
Down Arrow Up Arrow
View product citations for antibody "752852" on CiteAb
No Citations Found

No Citations are available for this Product

752852 Rev. 1

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.