-
Your selected country is
Brazil
- Change country/language
Old Browser
Looks like you're visiting us from {countryName}.
Would you like to stay on the current country site or be switched to your country?
BD™ Cytometric Bead Array (CBA) Human Inflammatory Cytokine Cytometric Bead Array (CBA) - I Kit
(RUO)Resolution of the individual bead populations in the BD CBA Human Inflammatory Cytokine Kit. Each population corresponds to an individual analyte.
BD™ Cytometric Bead Array (CBA) Human Inflammatory Cytokine Cytometric Bead Array (CBA) - I Kit
Human Inflammatory Cytokine Cytometric Bead Array (CBA) - I Kit
Regulatory Status Legend
Any use of products other than the permitted use without the express written authorization of Becton, Dickinson and Company is strictly prohibited.
Description | Quantity/Size | Part Number | EntrezGene ID |
---|---|---|---|
Human IL-8 Capture Beads | 1 Each (1 ea) | 51-9005819 | N/A |
Human IL-1β Capture Beads | 1 Each (1 ea) | 51-9005821 | N/A |
Human IL-6 Capture Beads | 80 Tests (1 ea) | 51-9005738 | N/A |
Human IL-10 Capture Beads | 80 Tests (1 ea) | 51-9005740 | N/A |
Human TNF Capture Beads | 1 Each (1 ea) | 51-9005724 | N/A |
Human IL-12p70 Capture Beads | 1 Each (1 ea) | 51-9005823 | N/A |
B Human Inflammation PE* Detection Reagent | N/A | 51-9004400 | N/A |
C Human Inflammatory Cytokine Standards | N/A | 51-2553KC | N/A |
D Cytometer Setup Beads | 1 Each (1 ea) | 51-9005731 | N/A |
E1 PE Positive Control Detector | 1 Each (1 ea) | 51-9005732 | N/A |
E2 FITC Positive Control Detector | 1 Each (1 ea) | 51-9005734 | N/A |
F Wash Buffer | N/A | 51-9004398 | N/A |
G Assay Diluent | 1 Each (1 ea) | 51-2432KC | N/A |
H Serum Enhancement Buffer | N/A | 51-9002150 | N/A |
Development References (13)
-
Bishop JE, Davis KA. A flow cytometric immunoassay for β2-microglobulin in whole blood. J Immunol Methods. 1997; 210:79–87. (Biology).
-
Camilla C, Defoort JP, Delaage M, et al. A new flow cytometry-based multi-assay system 1, Application to cytokine immunoassays. Cytometry Suppl. 1998; 8:132. (Biology).
-
Carson R, Vignali D. Simultaneous quantitation of 15 cytokines using a multiplexed flow cytometric assay. J Immunol Methods. 1999; 227:41–52. (Biology).
-
Chen, R, L Lowe, et al. Simultaneous quantification of six human cytokines in a single sample using microparticle-based flow cytometric technology. Clin Chem. 1999; 9:1693-1694. (Biology).
-
Collins DP, Luebering BJ, Shaut DM. T-lymphocyte functionality assessed by analysis of cytokine receptor expression, intracellular cytokine expression, and femtomolar detection of cytokine secretion by quantitative flow cytometry. Cytometry. 1998; 33:249-255. (Biology).
-
Cook, EB, JL Stahl, et al. Simultaneous measurement of six cytokines in a single sample of human tears using microparticle-based flow cytometry: allergics vs non-allergics. J Immunol Methods. 2001; 254:109-118. (Biology).
-
Dotti, G, B Salvodo, et al. Adenovector-induced expression of human-CD40-ligand (hCD40L) by multiple myeloma cells: A model for immunotherapy. Exp Hematol. 2001; 29:952-961. (Biology).
-
Fulton RJ, McDade RL, Smith PL, Kienker LJ, Kettman JR Jr. Advanced multiplexed analysis with the FlowMetrix system. Clin Chem. 1997; 43:1749-1756. (Biology).
-
Fulwyler M, McHugh TM. Flow microsphere immunoassay for the quantitative and simultaneous detection of multiple soluble analytes. Methods Cell Biol. 1994; 33:613-629. (Biology).
-
Kricka LJ. Diamandis EP, Christopoulos TK, ed. Immunoassay. Academic Press; 1996:389-404.
-
Lund-Johansen F, Davis K, Bishop J, de Waal Malefyt R. Flow cytometric analysis of immunoprecipitates: high-throughput analysis of protein phosphorylation and protein-protein interactions. Cytometry. 2000; 39(4):250-259. (Biology). View Reference
-
Oliver KG, Kettman JR, Fulton RJ. Multiplexed analysis of human cytokines by use of the FlowMetrix system. Clin Chem. 1998; 44:2057-2060. (Biology).
-
Stall, A, Q Sun, et al. A single tube flow cytometric multibead assay for isotyping mouse monoclonal antibodies, Abstract LB77. Experimental Biology Meeting. 1998. (Biology).
Please refer to Support Documents for Quality Certificates
Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described
Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims. Comparisons are not made against non-BD technologies, unless otherwise noted.
For Research Use Only. Not for use in diagnostic or therapeutic procedures.