Skip to main content Skip to navigation
PE-CF594 Mouse Anti-Human HLA-E
PE-CF594 Mouse Anti-Human HLA-E
Multiparameter flow cytometric analysis of HLA-E expression on human peripheral blood leucocyte populations. Human whole blood was stained with either BD Horizon™ PE-CF594 Mouse IgG1, κ Isotype Control (Cat No. 562292; Left Plot) or BD Horizon™ PE-CF594 Mouse Anti-Human HLA-E antibody (Cat No. 567432/567433; Right Plot). Erythrocytes were lysed with BD FACS Lysing Solution (Cat. No. 349202). A bivariate pseudocolor density plot showing the correlated expression of HLA-E (or Ig Isotype control staining) versus side light-scatter signals was derived from gated events with the forward and side light-scatter characteristics of intact human leucocyte populations. Flow cytometry and data analysis were performed using a BD LSRFortessa™ Cell Analyzer System and FlowJo™ software.
Multiparameter flow cytometric analysis of HLA-E expression on human peripheral blood leucocyte populations. Human whole blood was stained with either BD Horizon™ PE-CF594 Mouse IgG1, κ Isotype Control (Cat No. 562292; Left Plot) or BD Horizon™ PE-CF594 Mouse Anti-Human HLA-E antibody (Cat No. 567432/567433; Right Plot). Erythrocytes were lysed with BD FACS Lysing Solution (Cat. No. 349202). A bivariate pseudocolor density plot showing the correlated expression of HLA-E (or Ig Isotype control staining) versus side light-scatter signals was derived from gated events with the forward and side light-scatter characteristics of intact human leucocyte populations. Flow cytometry and data analysis were performed using a BD LSRFortessa™ Cell Analyzer System and FlowJo™ software.
Product Details
Down Arrow Up Arrow


BD Horizon™
HLA class I histocompatibility antigen, alpha chain E; HLAE; MHC Class I Antigen E
Human (QC Testing)
Mouse BALB/c IgG1, κ
Human HLA-E Recombinant Protein
Flow cytometry (Routinely Tested)
5 µl
Aqueous buffered solution containing BSA and ≤0.09% sodium azide.
RUO


Preparation And Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze. The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography. The antibody was conjugated to the dye under optimum conditions and unconjugated antibody and free dye were removed.

Recommended Assay Procedures

BD® CompBeads can be used as surrogates to assess fluorescence spillover (Compensation). When fluorochrome conjugated antibodies are bound to BD® CompBeads, they have spectral properties very similar to cells.  However, for some fluorochromes there can be small differences in spectral emissions compared to cells, resulting in spillover values that differ when compared to biological controls. It is strongly recommended that when using a reagent for the first time, users compare the spillover on cells and BD® CompBeads to ensure that BD® CompBeads are appropriate for your specific cellular application.

Product Notices

  1. Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
  2. Please observe the following precautions: Absorption of visible light can significantly alter the energy transfer occurring in any tandem fluorochrome conjugate; therefore, we recommend that special precautions be taken (such as wrapping vials, tubes, or racks in aluminum foil) to prevent exposure of conjugated reagents, including cells stained with those reagents, to room illumination.
  3. Source of all serum proteins is from USDA inspected abattoirs located in the United States.
  4. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  5. This reagent has been pre-diluted for use at the recommended Volume per Test. We typically use 1 × 10^6 cells in a 100-µl experimental sample (a test).
  6. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  7. An isotype control should be used at the same concentration as the antibody of interest.
  8. Texas Red is a registered trademark of Molecular Probes, Inc., Eugene, OR.
  9. CF™ is a trademark of Biotium, Inc.
  10. When excited by the yellow-green (561-nm) laser, the fluorescence may be brighter than when excited by the blue (488-nm) laser.
  11. This product is provided under an Agreement between BIOTIUM and BD Biosciences. The manufacture, use, sale, offer for sale, or import of this product is subject to one or more patents or pending applications owned or licensed by Biotium, Inc. This product, and only in the amount purchased by buyer, may be used solely for buyer’s own internal research, in a manner consistent with the accompanying product literature. No other right to use, sell or otherwise transfer (a) this product, or (b) its components is hereby granted expressly, by implication or by estoppel. This product is for research use only. Diagnostic uses require a separate license from Biotium, Inc. For information on purchasing a license to this product including for purposes other than research, contact Biotium, Inc., 3159 Corporate Place, Hayward, CA 94545, Tel: (510) 265-1027. Fax: (510) 265-1352. Email: btinfo@biotium.com.
  12. Because of the broad absorption spectrum of the tandem fluorochrome, extra care must be taken when using multi-laser cytometers, which may directly excite both PE and CF™594.
  13. Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
567432 Rev. 1
Antibody Details
Down Arrow Up Arrow
3D12

The 3D12 monoclonal antibody specifically recognizes Human Leukocyte Antigen E (HLA-E) that is widely expressed on leucocytes and some other cell types. Cell surface HLA-E is normally expressed as a noncovalent complex comprised of the ~45 kDa type I transmembrane, HLA-E heavy-chain glycoprotein, the ~12 kDa invariant β2-microglobulin (β2m) light chain, and a short bound peptide. Human HLA-E represents a nonclassical Major Histocompatibility Complex class I (MHC class Ib) molecule that is homologous to mouse H-2 Qa-1. Although structurally related to the classical, highly polymorphic MHC class Ia antigens (HLA-A, -B, -C), HLA-E shows limited polymorphism. HLA-E functions in the regulation or self-nonself discrimination of innate and adaptive immune responses. In addition to binding self peptides, the HLA-E complex can selectively bind and present peptides derived from bacterial or viral pathogen-infected cells, stressed cells, or tumor cells to elicit antigen-specific, HLA-E-restricted CD8+ T cell responses. The cell surface HLA-E complex likewise serves as a ligand for heterodimeric CD94:NKG2A inhibitory and CD94:NKG2C activating receptors that are differentially expressed on NK cells and some T cells. These ligand:receptor interactions can either suppress or promote NK or T cell-mediated responses. The 3D12 antibody reportedly binds to both free or complexed HLA-E heavy chain and can block HLA-E-dependent function.

This antibody is conjugated to BD Horizon PE-CF594, which has been developed exclusively by BD Biosciences as a better alternative to PE-Texas Red®. PE-CF594 excites and emits at similar wavelengths to PE-Texas Red® yet exhibits improved brightness and spectral characteristics. Due to PE having maximal absorption peaks at 496 nm and 564 nm, PE-CF594 can be excited by the blue (488-nm), green (532-nm) and yellow-green (561-nm) lasers and can be detected with the same filter set as PE-Texas Red® (eg, 610/20-nm filter).

567432 Rev. 1
Format Details
Down Arrow Up Arrow
PE-CF594
BD Horizon™ PE-CF594 dye is a part of the BD PE family of dyes. This tandem fluorochrome is comprised of a R-Phycoerythrin (PE) donor that has excitation maxima (Ex Max) of 496-nm and 566-nm and an acceptor dye with an emission maximum (Em Max) at 615-nm. PE-CF594, driven by BD innovation, is designed to be excited by the blue (488-nm), Green (532-nm) and yellow-green (561-nm) lasers and detected using an optical filter centered near 615 nm (e.g., a 610/20-nm bandpass filter). The donor dye can be excited by the Blue (488-nm), Green (532-nm) and yellow-green (561-nm) lasers and the acceptor dye can be excited by the green (532-nm) laser resulting in cross-laser excitation and fluorescence spillover. Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
altImg
PE-CF594
Yellow-Green 488 nm, 532 nm, 561 nm
496 nm, 566 nm
615 nm
567432 Rev.1
Citations & References
Down Arrow Up Arrow
View product citations for antibody "567432" on CiteAb

Development References (6)

  1. Joosten SA, Sullivan LC, Ottenhoff TH. Characteristics of HLA-E Restricted T-Cell Responses and Their Role in Infectious Diseases. J Immunol Res. 2016; 2016:1-11. (Biology). View Reference
  2. Joosten SA, van Meijgaarden KE, van Weeren PC, et al. Mycobacterium tuberculosis peptides presented by HLA-E molecules are targets for human CD8 T-cells with cytotoxic as well as regulatory activity.. PLoS Pathog. 2010; 6(2):e1000782. (Clone-specific: Flow cytometry). View Reference
  3. Lee N, Goodlett DR, Ishitani A, Marquardt H, Geraghty DE. HLA-E surface expression depends on binding of TAP-dependent peptides derived from certain HLA class I signal sequences.. J Immunol. 1998; 160(10):4951-60. (Immunogen: Flow cytometry, Immunoprecipitation, Western blot). View Reference
  4. Lee N, Llano M, Carretero M, et al. HLA-E is a major ligand for the natural killer inhibitory receptor CD94/NKG2A.. Proc Natl Acad Sci USA. 1998; 95(9):5199-204. (Clone-specific: Functional assay, Immunoprecipitation, Western blot). View Reference
  5. Llano M, Lee N, Navarro F, et al. HLA-E-bound peptides influence recognition by inhibitory and triggering CD94/NKG2 receptors: preferential response to an HLA-G-derived nonamer.. Eur J Immunol. 1998; 28(9):2854-63. (Clone-specific: Flow cytometry, Functional assay). View Reference
  6. Ogg G, Cerundolo V, McMichael AJ. Capturing the antigen landscape: HLA-E, CD1 and MR1.. Curr Opin Immunol. 2019; 59:121-129. (Biology). View Reference
View All (6) View Less
567432 Rev. 1

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures.