Skip to main content Skip to navigation
BD Horizon™ Real Fluorochromes

 

 

Minimize Cross-laser Spillover. Optimize Panel Resolution.

FormatSpectralConventionalRelative BrightnessSpillover
(1-low, 4-high)
Alternative To
Violet Laser
RV828 1Qdot 800, NovaFluor V800
Blue Laser
RB545 1(Unique position)
RB613 2PE-CF594, PE-Dazzle 594, BB630-P2, StarBright Blue 615
RB670 2PE-Cy5, BB660-P2, StarBright Blue 675
RB705 2PerCP-Cy5.5, BB700, StarBright Blue 700
RB744 1BB755-P
RB780 1PE-Cy7, BB790-P
RB824 1PerCP/Fire™ 806, StarBrightBlue 810
Yellow-Green Laser
RY586 1PE
RY610 1PE-CF594, PE-Dazzle 594
RY655 3PE-Cy5, StarBright Yellow 665
RY703 2PE-Cy5.5, StarBright Yellow 720
RY743 2PE/Fire 744
RY775 2PE-Cy7, StarBright Yellow 800
Red Laser
RR688 1Alexa Fluor 660, Spark NIR™ 685, NovaFluor R685, cFluor R685

 

 

prev
next

“The RB780 fluorochrome fits very well into the spectral gap of dyes primarily excited by the blue laser and can be separated beautifully from PE-Cy7 on instruments with blue and yellow-green lasers.”

 

“The RB780 fluorochrome fits very well into the spectral gap of dyes primarily excited by the blue laser and can be separated beautifully from PE-Cy7 on instruments with blue and yellow-green lasers.”

 

Dr. Florian Ebner
Distinguished Lab Scientist
Cancer Pharmacology and Disease Positioning

“I’m really excited about the BD Horizon RealBlue 780 Dye. The staining we have done so far with Ki-67 and Granzyme B can be seen very clearly, even with high dilutions.”

Testimonial image 1

“I’m really excited about the BD Horizon RealBlue 780 Dye. The staining we have done so far with Ki-67 and Granzyme B can be seen very clearly, even with high dilutions.”

Johannes Brandi
Researcher
Bernhard Nocht Institute for Tropical Medicine

"BD Horizon RealYellow™ 586 (RY586) Reagents look like the best alternative for PE and will simplify panel design on conventional flow cytometers. They can also be an additional dye for spectral panel design.”

"BD Horizon RealYellow™ 586 (RY586) Reagents look like the best alternative for PE and will simplify panel design on conventional flow cytometers. They can also be an additional dye for spectral panel design.”

Gert Van Isterdael, PhD
VIB Ghent University, Belgium