Skip to main content Skip to navigation

CD11b V450

Live Perm I Perm II Perm III Perm IV (0.5x) Perm IV (1.0x)
1x
1/4x

No Data Available

1/16x

No Data Available

Ratio between the MFI of stimulated vs control
Live Perm I Perm II Perm III Perm IV (0.5x) Perm IV (1.0x)
1x 5.94 3.05 2.24 2.39 1.69 1.44
1/4x - 3.11 2.79 3.1 2.17 1.69
1/16x - 2.76 2.78 3.37 2.01 1.46
Jump to Gating Hierarchy

CD11b A488

Live Perm I Perm II Perm III Perm IV (0.5x) Perm IV (1.0x)
1x
1/4x

No Data Available

1/16x

No Data Available

Ratio between the MFI of stimulated vs control
Live Perm I Perm II Perm III Perm IV (0.5x) Perm IV (1.0x)
1x 6.01 3.42 2.85 3.33 1.83 1.28
1/4x - 3.19 2.61 2.97 1.59 1.35
1/16x - 2.7 2.1 2.31 1.48 1.46
Jump to Gating Hierarchy

CD11b PE

Live Perm I Perm II Perm III Perm IV (0.5x) Perm IV (1.0x)
1x
1/4x

No Data Available

1/16x

No Data Available

Ratio between the MFI of stimulated vs control
Live Perm I Perm II Perm III Perm IV (0.5x) Perm IV (1.0x)
1x 7.28 2.75 2.17 2.83 1.13 1.13
1/4x - 3.42 2.94 3.49 1.52 1.2
1/16x - 3.3 2.82 3.03 1.5 1.41
Jump to Gating Hierarchy

CD11b PE-Cy7

Live Perm I Perm II Perm III Perm IV (0.5x) Perm IV (1.0x)
1x

No Data Available

1/4x

No Data Available

No Data Available

1/16x

No Data Available

No Data Available

No Data Available

Ratio between the MFI of stimulated vs control
Live Perm I Perm II Perm III Perm IV (0.5x) Perm IV (1.0x)
1x 8.17 - 1.54 2.27 1.77 1.29
1/4x - - 1.9 2.85 1.66 1.32
1/16x - - - 2.96 1.71 1.33
Jump to Gating Hierarchy

CD11b APC

Live Perm I Perm II Perm III Perm IV (0.5x) Perm IV (1.0x)
1x
1/4x

No Data Available

1/16x

No Data Available

Ratio between the MFI of stimulated vs control
Live Perm I Perm II Perm III Perm IV (0.5x) Perm IV (1.0x)
1x 6.49 2.78 2.04 2.68 1.17 1.02
1/4x - 3.3 2.41 2.6 1.43 1.38
1/16x - 2.57 1.77 1.83 1.36 1.44
Jump to Gating Hierarchy
Gating Hierarchy
Leukocytes
Leukocytes Leukocytes
Protocol & Other Details
Some permeabilization conditions that are unacceptable for resolution of CD11b staining within the lymphocyte population still allow detection of CD11b expression on granulocytes.
Notes
Human Surface Marker Antibody Concentrations:
Antibody titration is critical for successful post-permeabilization staining of CD markers and other cell surface antigens. The 1X concentration represents cells stained with the recommended test size for live cell stains (see product Technical Data Sheets for test size information). The 1/4X or 1/16X concentrations represent cells stained with 1/4 or 1/16 the antibody recommended for live cell stains.
Mouse Surface Marker Antibody Concentrations:
Antibody titration is critical for successful post-permeabilization staining of CD markers and other cell surface antigens. The 1X concentration represents cells stained with the recommended test size for live cell stains. The 1/4X or 1/16X concentrations represent cells stained with 1/4 or 1/16 the antibody recommended for live cell stains.
YG PE, YG PE-Cy7, and YG PE-Cy5:
PE, PE-Cy5, and PE-Cy7 fluorochromes may be excited by either a 488-nm blue laser or a 561-nm yellow-green laser. Since excitation by the yellow-green laser improves PE detection sensitivity, data collected from the 561-nm laser detection array (YG PE, YG PE-Cy5, and YG PE-Cy7) are provided along with data from the 488-nm laser detection array (PE, PE-Cy5, and PE-Cy7) when available.
Fold-Change Statistic:
Fold-change of a channel (e.g. pStat5-PE) is calculated as the ratio between the median fluorescence intensity of the stimulated sample (e.g. IL-2) and the median fluorescence intensity of the unstimulated sample (e.g. Control).
Percentile Distance Statistic:
Percentile distance is a measure of the spread between the 95th percentile and the 5th percentile of the fluorescence intensity of a channel (e.g. CD3-FITC). The distance is calculated as the ratio between the 95th percentile of a channel and the 5th percentile of a channel in its transformed space (log, linear, arcsinh or biexponential).
Permeabilization Buffers
BD Phosflow™ Perm/Wash Buffer I (557885) BD Phosflow™ Perm Buffer II (558052) BD Phosflow™ Perm Buffer III (558050) BD Phosflow™ Perm Buffer IV (560746)

Perm Buffer IV 1X vs. 0.5X:

 

Perm Buffer IV (provided as a 10X stock solution) may be used at a 1X or 0.5X concentration. The higher (1X) concentration provides optimal resolution of certain intracellular phosphoprotein stains but might result in increased cell loss and decreased ability to stain certain cell surface markers.

Entrez/About
About this Protein/NCBI Entrez Information: 3684
Keywords: 17-0118, 3684 ITGAM, CD11B, CR3A, MAC-1, MAC1A, MGC117044, MO1A cd 11b,mac,cd11b,mac-1,mac1,cd 11,cd-11b,cr3,cd-11 b,cd-11-b,cd 11 b,cd 11-b,cd-11,cd11 b,cd11,cd11-b

For Research Use Only. Not for use in diagnostic or therapeutic procedures.

23-23343-00

Refer to manufacturer's instructions for use and related User Manuals and Technical Data Sheets before using this product as described.

Comparisons, where applicable, are made against older BD technology, manual methods or are general performance claims. Comparisons are not made against non-BD technologies, unless otherwise noted.