Skip to main content Skip to navigation
For Professionals in Research

Overview

The BD® OMICS-Guard Sample Preservation Buffer is developed and optimised to address the need for high-quality biological sample preservation over an extended period of time when samples cannot be processed at the same time or location.

 

  • Provides a stress-free, one-step preservation protocol with minimum hands-on time
  • Optimised to preserve cells for a variety of downstream transcriptomic, proteomic and multiomic applications, including RNA-seq, CITE-seq, flow cytometry and qPCR​
  • Protects cell viability and preserves different cell populations in your samples for up to 72 hours at 4 °C
  • Developed and tested across multiple sample types: PBMCs and tissue samples
  • Available in two, easy-to-use formats: 50 mL bottle or 12 x 1 mL vials

 

Download our datasheet to learn more about the BD® OMICS-Guard Sample Preservation Buffer.

 
BD OMICS Guard Sample Preservation Buffer
performance1

One-Step Sample Preservation Workflow

 

 

Single-cell suspension

Tissue

Whole blood

Recommended usage

10,000 to 10 million cells per 1 mL BD® OMICS-Guard SPB

30 to 50 mg of tissue per 20 mL BD® OMICS-Guard SPB

1:1 Ratio of whole blood (with EDTA) and BD® OMICS-Guard SPB

Storage temperature

4 °C 

Storage duration

Up to 72 hours

Buffer handling

BD® OMICS-Guard SPB should be used with aseptic techniques to prevent contamination of the stock buffer. We recommend working under a laminar flow hood

Sample preservation protocol

  1. Collect single cells/dissociated single cells in suspension and spin at 400 x g for 5 min.
  2. Discard supernatant and resuspend the cells in BD® OMICS-Guard SPB as recommended above.
  3. Place cells at 4 °C for up to 72 h.
  4. After storage, spin cells at 800 x g for 5 min and discard the supernatant to remove the BD® OMICS-Guard SPB. No further washing is required.
  5. Resuspend the cells in desired buffer for downstream applications.
  1. Cut tissue into 30–50 mg pieces  and immediately place them into the BD® OMICS-Guard SPB.
  2. Place the preserved tissue at 4 °C for up to 72 h.
  3. After storage, dissociate the tissue by the desired method for your single-cell application.
  4. Resuspend the cells in desired buffer for downstream applications.
  1. Collect whole blood using EDTA as an anti-coagulant and mix with the same volume of BD® OMICS-Guard SPB by inverting 10 times.

    Note:
    It may be possible to use other anti-coagulants, though they have not been tested.

  2. Place the whole blood and BD® OMICS-Guard SPB mixture at 4 °C for up to 72 h.
  3. After storage, isolate desired cells.
    • Leukocytes: use a magnetic red blood cell depletion kit to remove the red blood cells and isolate PBMCs and granulocytes.
    • PBMCs: use density gradient separation methods (e.g., STEMCELL SepMate™ PBMC Isolation Tubes).
  4. Spin the isolated cells at 200 x g for 7 min to remove platelets.
  5. Resuspend cells in desired buffer for downstream applications.

Modifications to single-cell capture on the BD Rhapsody Single-Cell Analysis System

For cells/tissues/whole blood preserved in BD® OMICS-Guard SPB, ensure that the lysis time in the single-cell capture workflow is at least 5 min (can be longer per the specific assay instruction).

Improve Ab-Oligo Signal with the BD® AbSeq Enhancer Kit for BD® OMICS-Guard Buffer-Preserved Samples in CITE-seq

 

If staining with BD® AbSeq Antibody-Oligos after BD® OMICS-Guard Buffer preservation, use the BD® AbSeq Enhancer Kit to reduce nonspecific binding events and enhance the AbSeq signal.

 

Improve Ab-Oligo Signal with the BD AbSeq-Enhancer Kit
apps1

Heatmaps of AbSeq performance with and without the addition of the BD® AbSeq Enhancer Kit. Heatmaps of AbSeq median molecules per cell expression for different cell types are shown when the BD® AbSeq Enhancer Kit is either not added to the protocol (top) or added to the protocol (bottom) when using preserved cells. Nonspecific background signal (top) is eliminated, leading to better signal/noise, with the use of the BD® AbSeq Enhancer Kit (bottom), which closely matches that of the control data (bottom, left plot).

 

Download the BD® OMICS-Guard Sample Preservation Buffer product information sheet to access BD® AbSeq Enhancer Kit staining protocols

Applications

  

   

For Research Use Only. Not for use in diagnostic or therapeutic procedures. Refer to Manufacturer's instructions for use and related user manuals and technical sheets before using this product as described. Comparisons, where applicable, are made against older BD technology, manual methods or are general performance claims. Comparison are not made against non-BD technologies, unless otherwise noted.

Alexa Fluor is a trademark of Life Technologies Corporation. CF is a trademark of Biotium, Inc. Cy is a trademark of Global Life Sciences Solutions Germany GmbH or an affiliate doing business as Cytiva.