-
Reagents
- Flow Cytometry Reagents
-
Western Blotting and Molecular Reagents
- Immunoassay Reagents
-
Single-Cell Multiomics Reagents
- BD OMICS-Guard™ Sample Preservation Buffer
- BD® AbSeq Assay
- BD® Single-Cell Multiplexing Kit
- BD Rhapsody™ ATAC-Seq Assays
- BD Rhapsody™ Whole Transcriptome Analysis (WTA) Amplification Kit
- BD Rhapsody™ TCR/BCR Next Multiomic Assays
- BD Rhapsody™ Targeted mRNA Kits
- BD Rhapsody™ Accessory Kits
- BD® OMICS-One Protein Panels
-
Functional Assays
-
Microscopy and Imaging Reagents
-
Cell Preparation and Separation Reagents
Old Browser
Looks like you're visiting us from {countryName}.
Would you like to stay on the current location site or be switched to your location?
For Professionals in Research
BD Horizon RealViolet™, RealBlue™, RealYellow™ and RealRed™ Fluorochromes are engineered to help you push the boundaries of multicolor flow cytometry. These advanced fluorochromes minimize cross-laser spillover and enhance panel resolution, enabling high-quality data and more flexible panel design across both conventional and spectral cytometers. Whether you're expanding existing panels or building new ones, BD Horizon™ Real Dyes give you the clarity and control you need to accelerate discovery.
BD Horizon™ Real Fluorochromes offer:
-
Reduced spillover: Lower cross-laser excitation allows for cleaner emission profiles, which simplifies panel design and unlocks greater flexibility—giving you high-quality panels.
-
Excellent resolution of diverse antigen densities: These dyes range from moderate to very bright, giving you the ability to assign fluorochromes where they fit best.
-
Robust intracellular performance: BD Horizon™ Real Fluorochromes enable analysis of intracellular proteins like cytokines, transcription factors and phosphorylated signaling molecules—providing flexibility in various protocols.
-
Lot-to-lot consistency and stability: These fluorochromes provide lot-to-lot consistency across made-to-stock and BD OptiBuild™ Reagents, with proven photostability under typical lab lighting—so your results stay accurate and reproducible.
Dye Summary Table
Switch to Cleaner BD Horizon™ Real Dyes
| Format | Spectral | Conventional | Relative Brightness | Spillover (1-low, 4-high) | Alternative To | Products |
|---|---|---|---|---|---|---|
| Violet Laser | ||||||
| RV544 | ✓ | ‒ | 2 | Spark™ V538, StarBright™ Violet 535, Pacific Orange, Amethyst Orange, cFluor™ V547, Krome Orange | View | |
| RV828 | ✓ | ‒ | 1 | Qdot™ 800, NovaFluor™ V800 | View | |
| Blue Laser | ||||||
| RB545 | ✓ | ‒ | 1 | (Unique position) | View | |
| RB575 | ✓ | ✓ | 1 | PE, StarBright™ Blue 580 | View | |
| RB613 | ✓ | ✓ | 2 | PE-CF594, PE-Dazzle™ 594, BB630-P2, StarBright™ Blue 615 | View | |
| RB670 | ✓ | ✓ | 2 | PE-Cy5, BB660-P2, StarBright™ Blue 675 | View | |
| RB705 | ✓ | ✓ | 2 | PerCP-Cy5.5, BB700, StarBright™ Blue 700 | View | |
| RB744 | ✓ | ✓ | 1 | BB755-P | View | |
| RB780 | ✓ | ✓ | 1 | PE-Cy7, BB790-P | View | |
| RB824 | ✓ | ✓ | 1 | PerCP/Fire™ 806, StarBright™ Blue 810 | View | |
| Yellow-Green Laser | ||||||
| RY586 | ✓ | ✓ | 1 | PE | View | |
| RY610 | ✓ | ✓ | 1 | PE-CF594, PE-Dazzle™ 594 | View | |
| RY655 | ✓ | ✓ | 3 | PE-Cy5, StarBright Yellow 665 | View | |
| RY703 | ✓ | ✓ | 2 | PE-Cy5.5, StarBright™ Yellow 720 | View | |
| RY743 | ✓ | ✓ | 2 | PE/Fire™ 744 | View | |
| RY775 | ✓ | ✓ | 2 | PE-Cy7, StarBright™ Yellow 800 | View | |
| Red Laser | ||||||
| RR688 | ✓ | ‒ | 1 | Alexa Fluor™ 660, Spark NIR™ 685, NovaFluor™ R685, cFluor™ R685 | View | |
Chart contains representative fluorochromes compatible with a 5-laser spectral flow cytometer. Table may differ based on instrument configuration and settings. Spillover ranking is based on cross-laser excitation and does not take into account spillover into adjacent or residual detectors. PE and PE tandem dyes are excited by both the blue and yellow-green lasers. Be sure to check your instrument configuration.
Frequently Asked Questions
- What are the sizes of BD Horizon™ Real Fluorochromes?
The new fluorochromes in this family released to date are all less than 45 kDa.
- Are BD Horizon RealViolet™, RealBlue™, RealYellow™ and RealRed™ Reagents compatible with viability dyes?
Yes, this family of reagents is compatible with all viability dyes.
- Are these fluorochromes based on polymer technology?
These new fluorochromes leverage next-generation proprietary dye technology that is separate from Sirigen™ polymer technology.
- Do Real Reagents need special buffers or handling to prevent dye-to-dye interactions?
No. However, for human whole blood specimens, we recommend using BD Horizon™ Brilliant Stain Buffer (BSB) to minimize possible background that may be caused by anti-PEG antibodies.
- What advantages do BD Horizon RealYellow™ and BD Horizon RealBlue™ Reagent matched pairs provide?
Use BD Horizon RealYellow™ and BD Horizon RealBlue™ Reagent pairs together on appropriately equipped instruments with both blue and yellow-green lasers to build larger panels and for added flexibility when designing panels on both conventional and spectral flow cytometers.
- Do BD Horizon RealViolet™, BD Horizon RealBlue™, RealYellow™ and RealRed™ Reagents work on conventional flow cytometers?
Yes, most of the new BD Horizon™ Real dyes work well with existing cytometer configurations. Please ensure you have the appropriate configuration for any new reagent.
-
Brochures
-
BD Horizon RealYellow™ and RealBlue™ Reagents Brochure
-
Fluorochrome Faceoff Brochure
-
BD Horizon RealBlue™ 545 Reagents
-
BD Horizon RealBlue™ 613 and BD Horizon RealYellow ™ 610
-
BD Horizon RealBlue™ 705 Reagents
-
BD Horizon RealBlue™ 744 Reagents
-
BD Horizon RealBlue™ 780 Reagents
-
BD Horizon RealYellow™ 586 Reagents
-
BD Horizon RealYellow™ 775 Reagents
-
BD Horizon RealYellow™ 703 Reagents
-
Flyer and Posters
-
Performance Guide and Chart
For Research Use Only. Not for use in diagnostic or therapeutic procedures. Refer to Manufacturer's instructions for use and related user manuals and technical sheets before using this product as described. Comparisons, where applicable, are made against older BD technology, manual methods or are general performance claims. Comparison are not made against non-BD technologies, unless otherwise noted.