Skip to main content Skip to navigation
APC-H7 Mouse Anti-Human CD49d
Product Details
Down Arrow Up Arrow


BD™
Integrin α4 chain; Integrin alpha 4; ITGA4; IA4; alpha 4 subunit of VLA-4
Human
Mouse IgG1, κ
Flow cytometry
25 µg/mL
5 μL
V S215
3676
RUO (GMP)


658332 Rev. 1
Antibody Details
Down Arrow Up Arrow
9F10

The CD49d antibody, clone 9F10, is derived from the hybridization of mouse myeloma cells with spleen cells isolated from immunized mice.

The CD49d antibody recognizes the 150-kilodalton (kDa) type I transmembrane glycoprotein, integrin α. The CD49d antigen associates with one of two β integrin subunits, β(CD29) or β, to form the integrins αβ(VLA-4) or αβ, respectively.

658332 Rev. 1
Format Details
Down Arrow Up Arrow
APC-H7
The BD Horizon™ APC-H7 dye is a part of the BD APC red family of dyes. This tandem fluorochrome is comprised of a Allophycocyanin (APC) donor that has excitation maxima (Ex Max) of 659 nm and an acceptor dye, H7, with an emission maximum (Em Max) at 782 nm. APC-H7, driven by BD innovation, is designed to be excited by the Red (627-640 nm) laser and detected using an optical filter centered near 780 nm (e.g., a 760/60 nm bandpass filter). Please ensure that your instrument’s configurations (lasers and optical filters) are appropriate for this dye.
altImg
APC-H7
Red 627-640 nm
659 nm
782 nm
658332 Rev.1
Citations & References
Down Arrow Up Arrow

Development References (14)

  1. Albelda SM, Buck CA. Integrins and other cell adhesion molecules.. FASEB J. 1990; 4(11):2868-80. (Biology). View Reference
  2. Barclay AN, Brown MH, Law SKA, McKnight AJ, Tomlinson MG, van der Merwe PA. The Leucocyte Antigen FactsBook 2nd ed. San Diego: Academic Press; 1997.
  3. Centers for Disease Control. Update: universal precautions for prevention of transmission of human immunodeficiency virus, hepatitis B virus, and other bloodborne pathogens in healthcare settings. MMWR. 1988; 37:377-388. (Biology).
  4. Clinical and Laboratory Standards Institute. 2005. (Biology).
  5. Dittel BN, McCarthy JB, Wayner EA, LeBien TW. Regulation of human B-cell precursor adhesion to bone marrow stromal cells by cytokines that exert opposing effects on the expression of vascular cell adhesion molecule-1 (VCAM-1).. Blood. 1993; 81(9):2272-82. (Biology). View Reference
  6. Elices MJ, Osborn L, Takada Y, et al. VCAM-1 on activated endothelium interacts with the leukocyte integrin VLA-4 at a site distinct from the VLA-4/fibronectin binding site.. Cell. 1990; 60(4):577-84. (Biology). View Reference
  7. Hemler ME, Kassner P, Bodorova J. Schlossman SF, Boumsell L, Gilks W, et al, ed. Leucocyte Typing V: White Cell Differentiation Antigens. New York, NY: Oxford University Press; 1995:1617-1618.
  8. Lobb RR, Hemler ME. The pathophysiologic role of α 4 integrins in vivo. J Clin Invest. 1994; 94:1722-1728. (Biology).
  9. Nojima Y, Humphries MJ, Mould AP, et al. VLA-4 mediates CD3-dependent CD4+ T cell activation via the CS1 alternatively spliced domain of fibronectin.. J Exp Med. 1990; 172(4):1185-92. (Biology). View Reference
  10. Shimizu Y, Newman W, Gopal TV, et al. Four molecular pathways of T cell adhesion to endothelial cells: roles of LFA-1, VCAM-1, and ELAM-1 and changes in pathway hierarchy under different activation conditions.. J Cell Biol. 1991; 113(5):1203-12. (Biology). View Reference
  11. Shimizu Y, van Seventer GA, Horgan KJ, Shaw S. Costimulation of proliferative responses of resting CD4+ T cells by the interaction of VLA-4 and VLA-5 with fibronectin or VLA-6 with laminin.. J Immunol. 1990; 145(1):59-67. (Biology). View Reference
  12. Springer TA. Adhesion receptors of the immune system. Nature. 1990; 346(6283):425-434. (Biology). View Reference
  13. Zola H, Swart B, Nicholson I, Voss E. Leukocyte and Stromal Cell Molecules: The CD Markers. 2007. (Biology).
  14. van Dongen JJ, Lhermitte L, Böttcher S, et al. EuroFlow antibody panels for standardized n-dimensional flow cytometric immunophenotyping of normal, reactive and malignant leukocytes. Leukemia. 2012; 26(9):1908-1975. (Biology). View Reference
View All (14) View Less
658332 Rev. 1

Please refer to Support Documents for Quality Certificates


Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described


Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims.  Comparisons are not made against non-BD technologies, unless otherwise noted.

For Research Use Only. Not for use in diagnostic or therapeutic procedures. 

 

Although not required, these products are manufactured in accordance with Good Manufacturing Practices.