-
Your selected country is
Singapore
- Change country/language
-
Reagents
- Flow Cytometry Reagents
-
Western Blotting and Molecular Reagents
- Immunoassay Reagents
-
Single-Cell Multiomics Reagents
- BD® AbSeq Assay
- BD Rhapsody™ Accessory Kits
- BD® Single-Cell Multiplexing Kit
- BD Rhapsody™ Targeted mRNA Kits
- BD Rhapsody™ TCR/BCR Profiling Assays for Human and Mouse
- BD Rhapsody™ Whole Transcriptome Analysis (WTA) Amplification Kit
- BD® OMICS-Guard Sample Preservation Buffer
- BD Rhapsody™ ATAC-Seq Assays
-
Functional Assays
-
Microscopy and Imaging Reagents
-
Cell Preparation and Separation Reagents
-
Training
- Flow Cytometry Basic Training
-
Product-Based Training
- FACSAria Product Based Training
- FACSMelody Product-Based Training
- FACSLyric Product-Based Training
- FACSCanto Product-Based Training
- LSRFortessa Product-Based Training
- FACSymphony Product-Based Training
- FACSDuet Product-Based Training
- HTS Product-Based Training
- BD FACSDiscover™ S8 Cell Sorter Product Training
-
Advanced Training
-
Thought Leadership
-
Product News
- Blogs
- Scientific Publications
-
Events
- Nature Research Academies Workshop 2023
- CYTO 2023: Advancing the World of Cytometry
- Singapore Gene & Cell Therapy Conference 2023
- EuroFlow Educational Workshop
- Nature Research Masterclass 2023
- Novel Approaches to Single-Cell Plant Research: from Real-Time Imaging Cell Sorting to Single-Nuclei Transcriptomics
- Advances in Immune Monitoring Series
-
Product News
-
- BD® AbSeq Assay
- BD Rhapsody™ Accessory Kits
- BD® Single-Cell Multiplexing Kit
- BD Rhapsody™ Targeted mRNA Kits
- BD Rhapsody™ TCR/BCR Profiling Assays for Human and Mouse
- BD Rhapsody™ Whole Transcriptome Analysis (WTA) Amplification Kit
- BD® OMICS-Guard Sample Preservation Buffer
- BD Rhapsody™ ATAC-Seq Assays
-
- FACSAria Product Based Training
- FACSMelody Product-Based Training
- FACSLyric Product-Based Training
- FACSCanto Product-Based Training
- LSRFortessa Product-Based Training
- FACSymphony Product-Based Training
- FACSDuet Product-Based Training
- HTS Product-Based Training
- BD FACSDiscover™ S8 Cell Sorter Product Training
-
- Nature Research Academies Workshop 2023
- CYTO 2023: Advancing the World of Cytometry
- Singapore Gene & Cell Therapy Conference 2023
- EuroFlow Educational Workshop
- Nature Research Masterclass 2023
- Novel Approaches to Single-Cell Plant Research: from Real-Time Imaging Cell Sorting to Single-Nuclei Transcriptomics
- Advances in Immune Monitoring Series
- Singapore (English)
- Change country/language
Old Browser
This page has been recently translated and is available in French now.
Looks like you're visiting us from {countryName}.
Would you like to stay on the current country site or be switched to your country?
BD™ Cytometric Bead Array (CBA) 30 Plex Bead Mixture
(RUO)Example BD CBA 30 Plex Bead Mixture data acquired on a BD FACSArray bioanalyzer. Please note that while 30 bead populations will be detected when analyzing the 30 plex bead mixture using the FCAP Array Software, the relative positions of bead populations may vary batch-to-batch.
BD™ Cytometric Bead Array (CBA) 30 Plex Bead Mixture
Regulatory Status Legend
Any use of products other than the permitted use without the express written authorization of Becton, Dickinson and Company is strictly prohibited.
Preparation And Storage
Recommended Assay Procedures
1. Vortex the BD CBA 30 Plex Bead Mixture to bring beads into suspension.
2. Transfer 25 µl of the BD CBA 30 Plex Bead Mixture to the appropriate sample well or tube.
3. Add 175 µl of Wash Buffer (from one of the BD CBA Master Buffer Kits) to the bead sample. More Wash Buffer (275 µl) may be needed for samples in tubes.
4. Proceed with analysis on a BD flow cytometer that has been setup according to the instrument setup procedure included with the BD CBA Master Buffer Kits and export the FCS2.0 file for the 30 plex bead mixture.
5. Analyze the 30 plex bead mixture data file using the FCAP Array software clustering tool. If the FCAP Array software fails to identify 30 bead clusters, repeat steps 4 and 5 after repeating the instrument setup procedure. If the FCAP Array software is unable to identify 30 bead clusters from the repeat sample, instrument service may be required.
Note: Do not store the diluted beads. Prepare a new bead sample for each test.
The BD CBA 30 Plex Bead Mixture can be included as an additional sample when performing the instrument setup procedure included with the BD CBA Master Buffer Kits. A sample file generated for the bead mixture can be analyzed to demonstrate that the FCAP Array Software identifies 30 bead populations by using the Clustering Test Tool in the FCAP Array Software. For more information on the use of the Clustering Test Tool in the FCAP Array Software, refer to Chapter 8 in the FCAP Array Software User's Guide.
Product Notices
- Source of all serum proteins is from USDA inspected abattoirs located in the United States.
- Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
The BD™ Cytometric Bead Array (CBA) 30 Plex Bead Mixture is a cocktail containing 30 bead populations from the BD CBA Flex Set. Each bead population has distinct fluorescence intensities in resolvable in the NIR and Red channels of a BD FACSArray™ bioanalyzer, the FL3 and FL4 channels of a BD FACSCalibur™ flow cytometer or the APC and APC-Cy7 channels of digital BD flow cytometers. The bead mixture contains bead positions A4, A5, A6, A7, A8, A9, B4, B5, B6, B7, B8, B9, C4, C5, C6, C7, C8, C9, D4, D5, D6, D7, D8, D9, E4, E5, E6, E7, E8 and E9. The BD CBA 30 Plex Bead Mixture is useful as a control sample to demonstrate that the instrument has been properly setup for analysis. It is only a guarantee that the instrument and FCAP Array Software (Cat. No. 641488) can analyze the 30 plex correctly, it does not a guarantee that a given experiment using the BD CBA Flex Set assays will work properly.
Please refer to Support Documents for Quality Certificates
Global - Refer to manufacturer's instructions for use and related User Manuals and Technical data sheets before using this products as described
Comparisons, where applicable, are made against older BD Technology, manual methods or are general performance claims. Comparisons are not made against non-BD technologies, unless otherwise noted.
For Research Use Only. Not for use in diagnostic or therapeutic procedures.
Report a Site Issue
This form is intended to help us improve our website experience. For other support, please visit our Contact Us page.